|
Resumen del manual
Junction Box Lamp Holders . Turn power off at the fuse or circuit breaker. . Remove the existing light fixture, if present. 598-1096-01 -2 TEST AND ADJUSTMENT . Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute calibration period before it will detect motion. When first turned on, wait 1 1/2 minutes. . Turn the RANGE control to the mid position and the ON-TIME control to the TEST position. ON-TIME RANGE 10 5 1 TEST MIN MAX Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas wherepets or trafficmay trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. 8 ft. (2.4m) 70 ft. (21m) Maximum Range The sensor is less sensitive to motion directly towards it, most sensitive to motion across its field of view. Maximum 180° Coverage Angle Motion Sensor Least Sensitive Most Sensitive Motion . Loosen the clamp screw in Clamp the sensor ball joint and Screw gently rotate the sensor. . Walk through the cover- Ball age area noting where you Joint are when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down, or side-Aim Sensor ways to change the cover-Down for Short age area. Keep the sen-Coverage sor at least 1" (2.5 cm) away from the lamps. . Adjust the RANGE as needed. RANGE set too Aim Sensor high may increase false Higher for Long triggering. Coverage . Secure the sensor head by tightening the clamp screw. Do not overtighten the screw. . Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes). Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m). SPECIFICATIONS Range . . . . . . . . . . . . . . Upto70ft. (21 m) [varies with surrounding temperature]. Sensing Angle. . . . . . . . Up to 180° Electrical Load. . . . . . . . Up to 500 Watt (4.2A) Maxi mum Incandescent [Up to 250 Watt maximum each lamp holder.] Power Requirements. . . 120 VAC, 60 Hz Operating Modes. . . . . . TEST, AUTO and MANUAL MODE Time Delay . . . . . . . . . . 1 , 5, 10 minutes Range . . . . . . . . . . . . . . Adjustable Atlas Lighting Products, Inc. reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold. 598-1096-01 -3 TROUBLESHOOTING GUIDE If you experience a problem with your Light Control, first follow this guide. For additional assistance write to: Atlas Lighting Products, Inc. • Customer Service Department • P.O. Box 2348 • Burlington, NC 27216 SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not 1. Light switch is turned off. Lights stay on 1. A lamp is positioned too close to the sensor come on. 2. Light is loose or burned out. continuously. or pointed at nearby objects that cause heat 3. Fuse is blown or circuit breaker is turned to trigger the sensor. (Reposition the lamp off. away from the sensor or nearby objects). 4. Daylight turn-off is in effect (recheck 2. Light Control is pointed toward a heat after dark). source like an air vent, dryer vent, or 5. Incorrect circuit wiring, if this is a new brightly-painted heat-reflective surface. installation. (Reposition sensor). 6. Re-aim the sensor to cover desired area. 3. Light Control is in Manual Mode. (Switch to Auto.) Lights come on 1. Light Control may be installed in a relain daylight. tively dark location. Lights flash on 1. Heat or light from the lamps may be turn2. Light Control is in Test. (Set control and off. ing the Light Control on and off. (Reposiswitch to an ON-TIME position). tion the lamps away from the sensor). 2. Heat being reflected from other objects may Lights come on for 1. Light Control may be sensing small be affecting the sensor. (Reposition sensor). no apparent rea animals or automobile traffic (re-aim 3. Light Control is in the Test mode and son. sensor). warming up. (Flashing is normal under 2. Range is set too high.(Reduce Range). these conditions). 4. Light Control is detecting a light source. (Reposition Light Control or lamp). Lights flash 1. Sensor is detecting its own lights. (Repoonce, then stay sition lamps to keep area below the sen off in Manual sor relatively dark.) Mode. FIVE YEAR LIMITED WARRANTY Atlas Lighting Products, Inc. warrants against defects in materials or workmanship for a period of five years from the date of purchase for use, and ag...
Otros modelos de este manual:Vídeo - GUARDIAN PRO MLGS180W (447.5 kb)