Manual de usuario Bock s, modelo 51EC

Fabricar: Bock s
Tamaño del archivo: 180.73 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Attach a small plastic tube to the bleed valve fitting on the pump and run to a gallon container. Turn on the electricity and set the thermostat so the burner motor runs. The heater will not ignite when the bleed valve is open. Bleed the line until the oil is completely clear, not milky or opaque. The oil must be transparent and free of air bubbles and froth. To keep the burner control from locking out while bleeding the pump, attach a jumper between the flame detector terminals after starting the burner. Remove the jumper when finished. Shut the bleed valve and the burner will ignite. Remove the plastic tubing. Set the pump pressure to 100 PSI for Wayne, Carlin and Beckett burners and 150 PSI for Riello burners. 4. Adjust the burner combustion air in accordance with the burner manufacturer’s instructions. Using combustion instruments, check the C02 and smoke. The C02 should be at least 10 1/2% minimum with 0-to-trace smoke on the Bacharach scale. – 6 – MAINTENANCE MEASURING THE OUTCOMING WATER TEMPERATURE Have the oil burner serviced once each year by a qualified oil burner service person. Service should comply with the burner manufac- turer’s recommenda- tions and include: – 6 – MAINTENANCE MEASURING THE OUTCOMING WATER TEMPERATURE Have the oil burner serviced once each year by a qualified oil burner service person. Service should comply with the burner manufac- turer’s recommenda- tions and include: 5. While the burner is operating, disconnect one of the yellow cad cell wires. Check to see that the burner control locks out in the time specified on the control. Reattach the wire and reset the control. The burner should restart. Note: You may have to wait a minute before resetting the control. 6. The thermostat is factory set at 120°F for residential use. (See caution on page 1 regarding temperature variations. It is the responsibility of the homeowner and installer to verify that the installer follows the recommended quantitative testing for measuring the outcoming water temperature. To make sure that the system works properly after installation and in the future, it is recommended that the heater’s performance be measured and monitored. Run water out of the tap nearest the heater until it comes out warm. Using a calibrated thermometer, take a measurement. If the water is not at a suitable temperature for the installation, have a qualified service person adjust the aquastat. Contact Bock for further information on the thermometer if needed. WARNING: Hydrogen gas can be produced in a hot water system served by a heater that has not been used for a long period of time (generally two weeks or more.) Hydrogen gas is extremely flammable. To reduce the risk of injury, open the hot water faucet at the highest location in the house for several minutes before using any electrical appliance connected to the hot water system. If hydrogen is present, there may be an unusual sound such as air escaping through the pipe as the water begins to flow. Do not smo...

Otros modelos de este manual:
Calentadores de Agua - 33E (180.73 kb)
Calentadores de Agua - 33PP (180.73 kb)
Calentadores de Agua - 40E (180.73 kb)
Calentadores de Agua - 40PP (180.73 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría