|
Resumen del manual
When odors are present, the addition of charcoal filters will neutralize odors, such as cooking odors, pet odors, cigar and cigarette odors, ozone, etc. Optional charcoal filters are available for your Air Cleaner. Refer to the parts list for the charcoal filter part number for your Air Cleaner. Charcoal filters require replacement. They cannot be washed. While there is no rule of thumb for how often they should be changed, you can use your best judgement based on the odors you perceive in your environment. 3 PREINSTALLATION PREINSTALLATIONPREINSTALLATIONPREINSTALLATIONPREINSTALLATIONPREINSTALLATION Not to Exceed 20 Air Flow Air Flow Furnace Opening Electronic Air Cleaner Opening Furnace Electronic Transition Section Air Cleaner (if Needed) Figure 3 LOCATING THE AIR FILTER LOCATING THE AIR FILTERLOCATING THE AIR FILTERLOCATING THE AIR FILTERLOCATING THE AIR FILTERLOCATING THE AIR FILTER Your air filter must be mounted in the return air duct of a central forced-air system, on the air entering side of your furnace. (See Figure 3 for example.) Select a location that meets the following: 1. The face of the cell will be at a right angle to the air stream. 2. Allow the following clearances to permit removal of cells and pre-filters: (See Figures 4 and 5) Model SST1000 - 14 inches Model SST1400 - 15 inches Model SST1600 - 14 inches Model SST2000 - 15 inches For complete dimension data refer to Figure 5. 3. The air filter is not to be placed in the discharge of either the heating or cooling unit. 4. IMPORTANT: IMPORTANT:IMPORTANT:IMPORTANT:IMPORTANT:IMPORTANT: If atomizing spray type humidifier is used, it must be installed downstream from the air filter. If your furnace duct system has a pre-installed boot, discard front cover of boot and slide the air cleaner component inside the boot. For installation of Air Cleaner Retrofit (ACR) kits, see page 13. If furnace opening cannot be enlarged to required size, a transition sheet metal section must be used. Transition must be planned for each job. Reduction should not be more than 4 inches per linear foot, approximately 20 angular degrees (Figure 3). DIRECTION OF AIR FLOW THROUGH THE DIRECTION OF AIR FLOW THROUGH THEDIRECTION OF AIR FLOW THROUGH THEDIRECTION OF AIR FLOW THROUGH THEDIRECTION OF AIR FLOW THROUGH THEDIRECTION OF AIR FLOW THROUGH THE AIR CLEANER AIR CLEANERAIR CLEANERAIR CLEANERAIR CLEANERAIR CLEANER Your air cleaner is shipped from the factory with air flow from left-to-right. If this air flow is suitable for the installation, no further changes need to be made (Figure 4). For right-to-left air flow, remove both pre-filter and cell sec (Interchangeable) (Interchangeable) Collecting Cell Collecting Cell Outlet Box Cabinet Power Pack Handle Contact Button Contact Pre-Filters Button (Interchangeable) See text for Cell Removal Clearance Figure 4 Knockouts for 3/4" Conduit 6 7/8" (three sides) C F E D B A MODEL NO. A B C D E F SST1000 24 3/4 21 5/16 18 5/8 13 9/16 16 7/16 19 1/16 SST1400 29 11/16 26 1/4 23 5/8 13 9/16 16 7/16 19 1/16 SST1600 25 1/2 21 5/16 18 5/8 17 3/4 20 5/8 23 3/8 SST2000 29 11/16 26 1/4 23 5/8 17 3/4 20 5/8 23 3/8 Figure 5 tions. Turn cells upside down (with the same end facing the cabinet opening). This will locate the ionizing wires at the right, and both contact buttons and cell handles will be facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells. After installing the cell sections, install pre-filters in cabinet tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires). 4 Air Flow Rear View Air Flow Rear View TYPICAL MOUNTING POSITIONS TYPICAL MOUNTING POSITIONSTYPICAL MOUNTING POSITIONSTYPICAL MOUNTING POSITIONSTYPICAL MOUNTING POSITIONSTYPICAL MOUNTING POSITIONS HIGHBOY FURNACE HIGHBOY FURNACEHIGHBOY FURNACEHIGHBOY FURNACEHIGHBOY FURNACEHIGHBOY FURNACE (Figure 9) (Figure 9)(Figure 9)(Figure 9)(Figure 9)(Figure 9) Installation beneath furnace. Less than Cleaner mounts horizontally, 7 Inches Offset where return air enters from below. Raise furnace and install beneath base. At Least 9 Inches Air Flow Figure 10 Air Flow HORIZONTAL FURNACE HORIZONTAL FURNACEHORIZONTAL FURNACEHORIZONTAL FURNACEHORIZONTAL FURNACEHORIZONTAL FURNACE (Figure 11) (Figure 11)(Figure 11)(Figure 11)(Figure 11)(Figure 11) Cleaner is mounted vertically in the return duct near furnace. Figure 6 BASEMENT FURNACE BASEMENT FURNACEBASEMENT FURNACEBASEMENT FURNACEBASEMENT FURNACEBASEMENT FURNACE (LOWBOY) (Figure 6) (LOWBOY) (Figure 6)(LOWBOY) (Figure 6)(LOWBOY) (Figure 6)(LOWBOY) (Figure 6)(LOWBOY) (Figure 6) Cleaner is mounted horizontally in return plenum, just above furnace. Air Flow Rear View Figure 7 COUNTERFLOW COUNTERFLOWCOUNTERFLOWCOUNTERFLOWCOUNTERFLOWCOUNTERFLOW FURNACE (Figure 7) FURNACE (Figure 7)FURNACE (Figure 7)FURNACE (Figure 7)FURNACE (Figure 7)FURNACE (Figure 7) Cleaner is mounted horizontally in return duct or plenum, just above furnace. Figure ...
Otros modelos de este manual:Aire - SST1600 (288.38 kb)
Aire - SST2000 (288.38 kb)