NOTE NOTA CHECKING THE WATER DISPENSER LINE (OPTIONAL) 1) In order to operate the ice maker properly, water pressure of 1.4 ~ 10 kgf/cm2 is required. In this range a 100 cc paper cup can be filled in 10 seconds. 2) The water filter removes particles. It does not sterilize or destroy any micro-organisms. 3) If the refrigerator is installed in an area with low water pressure (below 1.4kgf/cm2), you should install a booster pump to compensate for the low pressure. 4) Ensure the water storage tank inside the refrigerator is preperly filled initially. Push the water dis penser lever until the water runs from the outlet. NOTE A universal water supply kit is available at extra cost from your dealer. The refrigerator manufacturer recommends using a water supply kit containing copper tubing. Checking the Parts Purifier (Interior model) Sealing tape Purifier lock stationWater line Tapping screw x 12EA Clip A x 8EA INSTALLATION INSTRUCTIONS Tightening band Purifier (Exterior model) 27 INSTALLING OF THE WATER DISPENSER LINE For Interior Model (Case 1) Connecting to water supply line 1. Cold Water line -Shut off the main water supply line and turn the Ice 2. Pipe Clamp.maker to the off position. 3.Copper (or Plastic) line -Locate the nearest cold drinking water line. 4.Compression Nut -Follow the instructions in the ice maker installation kit. 5.Compression Sleeve 6.Shut Off Valve 7.Packing Nut. Connect the water line to the refrigerator -Slip the compression nut and plastic ferrule through the plastic tube. -After inserting the sleeve, tighten the compres-sion nut onto 1/4” compression fitting(union). Do not overtighten the compression nut. NOTE -Slip the compression ferrule and nut on copper(or plastic) tubing as shown. Tighten the comperssion nut onto the com-pression fitting(union). -Turn water on and check for any leakege. NOTE Waterline must be connected to drinkable water only (Case 2) Nut Check the water supply line Compression Ferrule Sleeve Compressionfitting Ferrule Compression Nut Connect the water pipe with coupler and tap. -Close the main water tap. -Connect coupler “A” to the tap. -Every join should be protected with sealing tape. WARRANTY INFORMATION This water line installation is not covered by the refriger-ator or ice maker manufacturer's warranty. Follow these instructions carefully to minimise the risk of expensive water damage. Note: If the coupler does not fit on the current tap, go the nearest authorised service dealer and purchase the right couplers fittings. CAUTION The water line must be connect-ed to the cold water pipe. If it is connected to the hot water pipe, it may cause the purifier to malfunction. COUPLER “A” TAP 28 INSTALLING THE WATER DISPENSER LINE - Remove the compressor cover of the refrigerator. - Connect the water line to the valve, as shown in the figure. - When connected, check if there is any leakage. If any, repeat the connection. - Reattach the compressor cover of the refrigerator. WATER LINE CONNECTION NUT Connec...

Otros modelos de este manual:
Refrigeradores - 21KCMS (2.08 mb)
Refrigeradores - 21KCSW (2.08 mb)
Refrigeradores - 21KLDW (2.08 mb)
Refrigeradores - 21KLLB (2.08 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría