|
Resumen del manual
9. Tighten six knobs in a staggered pattern so all screws are tightened evenly. 10. Pump is now ready to return to Voltage can shock, burn, or cause death. Disconnect power before working on pump or motor. Disconnect power at APB075PRO, APB100PRO, APB150PRO, APB200PRO, APB300PRO, APB100UPRO, APB150UPRO, APB200UPRO and APB250UPRO source, lock out the power, and place a tag on the dedicated GFCI circuit breaker indicating the power is to remain off. Troubleshooting Guide Read and understand safety and operating instructions in this manual before doing any work on pump! Only qualified personnel should electrically test pump motor! WATER LEAKING AROUND MOTOR: A water leak in the area of the motor to pump connection indicates a mechanical seal failure and a shock hazard. Take pump out of service and replace seal immediately to avoid damage to other components and to reduce risk of electric shock. Refer to pump maintenance section. FAILURE TO PUMP: REDUCED CAPACITY OR DISCHARGE PRESSURE SUCTION LEAKS/LOST PRIME: 1. Pump must be primed; make sure that pump body and basket body are full of water. See priming instructions. 2. Make sure there are no leaks in suction piping. 3. Make sure suction inlet is well below the water level to prevent pump from sucking air. 4. Lower pump closer (vertically) to water source or install check valve in suction line. CLOGGED PIPE/TRAP/IMPELLER, WORN IMPELLER: 5. Make sure suction trap is not clogged; if it is, clean trap and strainer. See Maintenance section. 6. Make sure impeller is not clogged (follow steps 1 through 7 under “DISASSEMBLY”, Page 6; check impeller for clogging; follow steps 7 through 10 under “REASSEMBLY”, Pages 6 - 7, for reassembly). 7. Impeller and diffuser may be worn. If so, order replacement parts from “ Repair Parts List”, on pages 10 and 11. 8. Pump may be trying to push too high a column of water. If so, a “higher head” pump is needed. Call AquaPRO ® Systems 1-877-278-2797. ELECTRICAL: 9. Pump may be running too slowly; check voltage at motor terminals and at meter while pump is running. If low, see wiring instructions or consult power company. Check for loose connections. 10. Pump may be too hot. A. Check line voltage; if less than 90% or more than 110% of rated voltage consult a licensed electrician. B. Increase ventilation. C. Reduce ambient temperature. D. Tighten any loose connections. MECHANICAL TROUBLES AND NOISE 1. If suction and discharge piping are not adequately supported, pump assembly will be strained. See “Installation”, Page 3 - 4. 2. Do not mount pump on a wooden platform! Securely mount on concrete platform for quietest performance. Use anchor holes provided in pump base. 7 Owner’s Manual Swimming Pool Pump Flow Rates 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 Flow Rate in USGPM AquaPRO Systems Full-Rated Characteristic Curves 60 Cycle 1 Phase 3450 RPM 10/20/08 APB075PRO 0.75 HP APB100PRO 1 HP APB150PRO 1.5 HP APB200PRO 2 HP APB300PRO 3 HP Swimming...
Otros modelos de este manual:Piscinas - APB100PRO (2.36 mb)
Piscinas - APB200PRO (2.36 mb)
Piscinas - APB250UPRO (2.36 mb)
Piscinas - APB075PRO (2.36 mb)