Refer to the latest revisions of CAN/CGA-B149.1 and B149.2. 4 ft Minimum 4 ft Minimum 1 ft Minimum 4 ft Minimum 3 ft Minimum 10 ft Minimum Forced Air Inlet For installations in Florida, that must comply with the Florida Building Code 2001, follow the directions on p14 for the installation of hurricane tie-down brackets for all models. 13 14 FLORIDA BUILDING CODE 2001 WIND SPEED = 150 MPH, 3 SECOND GUST EXPOSURE = C HOT B 28” 40” 3” Min. Conc. Pad by others 3” Min. Conc. Pad by others Min. Edge Distance Min. Edge Distance (1)–1/4” x 1-3/4” S.S. Tapcon Bolt & Washer Ea. Raypak Pallet Anchor Bracket Use hole closest to unit (4 total) (1)–1/4” x 1-3/4” S.S. Tapcon Bolt & Washer Ea. Raypak Pallet Anchor Bracket Use hole closest to unit (4 total) 2” x 8” x 1/8” Raypak Pallet Anchor Bracket (4 Total) 1/4” x 1-3/4” S.S. Tapcon Bolt & Washer NOTE: Use hole closest to unit with washer overlapping edge of unit. 6” 6” 206/266/336/406 Atmospheric MODEL # B 206 20” 266 23” 336 26” 406 29” INDOOR HEATER INSTALLATION The heater is also design-certified for indoor installation when equipped with the approved drafthood. For Canada, indoor installation is restricted to an enclosure that is not occupied and does not directly communicate with an occupied area. Refer to the latest edition of CAN/CGA-B149.1 and B149.2 for specific requirements. Locate heater as close as is practical to a chimney or gas vent. Heater must always be vented to the outside. See Vent Piping section (pg. 17-18) for details. Minimum allowable space is shown on the nameplate. WARNING: Indoor heaters require a drafthood that must be connected to a vent pipe and properly vented to the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning. OUTDOOR STACK / INDOOR STACK NOTE: The outdoor and indoor stacks are optional equipment and do not come standard with the heater. OUTDOOR STACK KIT INCLUDES: (1) Drafthood, painted (1) Adapter plate (3) Mounting brackets (clips) (1) Top panel cover (2) 1-foot sections of metal tape (3) Screws (1) Instructions Clips INDOOR STACK KIT INCLUDES: (1) Drafthood, unpainted (1) Adapter plate (3) Mounting brackets (clips) (3) Screws (1) Instructions Clips OUTDOOR STACK INDOOR STACK Model Part No. Part No. 206A/207A 009834 009838 266A/267A 009835 009839 336A/337A 009836 009840 406A/407A 009837 009841 **REFER TO INSTALLATION INSTRUCTIONS INSIDE BOX FOR INSTRUCTIONS ON HOW TO INSTALL OUTDOOR/INDOOR STACK. 15 SPECIFICATIONS AND DIMENSIONS ATMOSPHERIC UNITS B Heater Model BTUH Input (000) (A) Cabinet Width (B) Flue Dia. (C) Indoor Drafthood (J) Min. Gas Conn. Water Conn. Shipping Weights (lbs) Standard Heater w/Stackless Top ASME Heater w/Stackless Top Indoor Draft- hood R206A 199.5 20” 6” 61-5/8” 11-3/4” 3/4” 2” 187 206 12 R266A 266.0 23” 7” 62” 11” 3/4” 2” 210 229 15 R336A 332.5 26” 8” 63” 10-5/8” 3/4” 2” 230 249 17 R406A 399.0 29” 9” 64-9/16” 12-1/8” 3/4” 2” 249 268 20 C INDOOR DRAFTHOOD 38" 13-1/4" GAS CONNECTION J A 26-5/8" (28-5/8" ASME) 32-11/16" ELECTRICAL CONNECTION 40" STACKLESS OUTDOOR TOP 28" 4-3/8" (3-3/8" ASME) 8-7/8" (6-5/8" ASME) Designation for a Digital heater using propane gas is “EP”; a Digital heater using natural gas is “EN”. Designation for a Millivolt heater using propane gas is “MP”; a Millivolt heater using natural gas is “MN”. Prefix “C” is for cast iron (ASME) headers; “P” is for plastic (polymer) headers. Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing. EXAMPLE: P-R406A-EN-X = Plastic headers, 406 model size, digital, natural gas, cupro-nickel. Reduce input 4% for each 1000 ft above sea level when installed above 2000 ft elevation. For Canada, no de-rating is required for elevations up to 4500 ft Plastic (polymer) headers cannot be used for ASME installations. 16 SPECIFICATIONS AND DIMENSIONS Low NOx UNITS B C INDOOR DRAFTHOOD 31-13/16" 7-3/4" GAS CONNECTION J A 20-1/2" (22-1/2" ASME) 26-1/2" ELECTRICAL CONNECTION 34" STACKLESS OUTDOOR TOP 28" 4-3/8" (3-3/8" ASME) 8-7/8" (6-5/8" ASME) Shipping Weights (lbs) Standard ASME BTUH (A) (B) (C) (J) Heater Heater Indoor Heater Input Cabinet Flue Indoor Min. Gas Water w/Stackless w/Stackless Draft- Model (000) Width Dia. Drafthood Conn. Conn. Top Top hood R207A 199.5 20” 6” 55-5/8” 11-3/4” 3/4” 2” 174 193 12 R267A 266.0 23” 7” 56” 11” 3/4” 2” 197 216 15 R337A 332.5 26” 8” 57” 10-5/8” 3/4” 2” 219 238 17 R407A 399.0 29” 9” 58-1/2” 12-1/8” 3/4” 2” 237 256 20 Designation for a Digital heater using natural gas is “EN”. Prefix “C” is for cast iron (ASME) headers; “P” is for plastic (polymer) headers. Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing. EXAMPLE: P-R407A-EN-X = Plastic headers, 407 model size, digital, natural gas, cupro-nickel. For altitudes above 5,000 ft., consult the factory. For Canada, no de-rating is required for elevations up to 4500 ft. Plastic (polymer) headers cannot be used for ASME installations. 17 COMBUSTION AND VENTILATION AIR (Indoor Units Only) The heater must have both combu...
Otros modelos de este manual:Piscinas - 206A (3.52 mb)
Piscinas - 207A (3.52 mb)
Piscinas - 267A (3.52 mb)
Piscinas - 336A (3.52 mb)