Iniciar sesión:
Votos - 1, Puntuación media: 4 ( )

Manual de usuario Empire Comfort Systems, modelo CIDV-30-7

Fabricar: Empire Comfort Systems
Tamaño del archivo: 1.42 mb
Nombre del archivo: 445b0146-2f16-4708-a36d-f014428d960d.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


• Do not use the phone in your building. • Immediately call your gas supplier from a neighbor's phone. • Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. POUR VOTRE SECURITE: Que faire si vous sentez une odeur de gaz: • Ne pas tenter d'allumer d'appareil. • Ne touchez a aucun interrupteur. Ne pas vous servir des telephones se trouvant dans le batiment ou vous vous trouvez. • Evacuez la piece, le batiment ou la zone. • Appelez immediatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. • Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. AVERTISSEMENT: Une installation, un reglage, une modification, un entretien ou une maintenance incorrects peuvent entrainer des dommages materiels, des lesions corporelles ou la perte de vies humaines. Consulter le manuel des usagers fourn avec ce generateur d'air chaud. AVERTISSEMENT: Quiconque ne respecte pas a la lettre les instructions dans le present manuel risque de declencher un incendie ou une explosion entraiant des dommages materiels, des lesions corporelles ou la perte de vies humaines. Instructions to Installer Specifications 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with appliance. 3. Installer should show owner how to start and operate appliance and thermostat. WARNING: Any change to this appliance or its control can be dangerous. This is a heating appliance and any panel, door or guard removed for servicing an appliance must be replaced prior to operating the appliance. General Information This appliance is design certified in accordance with American National Standard/CSA Standard ANSI Z21.88-1998/CSA 2.33-M98 by the American Gas Association and Canadian Gas Association as a Direct Vent Fireplace and should be installed according to these instructions. The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system. Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change. Notice During initial firing of this unit, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. WARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness. Appliance must not be connected to a chimney flue that is servicing a separate solid-fuel burning appliance. Attention: All vent runs must have a minimum VERTICAL rise of two feet. If the vent run is directly behind the appliance, you must attach Simpson Dura-Vent 36" snorkel, part number SD-981 on the exterior of the building. See Venting Requirements, page 11. Model CIDV-30 Input BTU/HR (KW/H) Max (LP/NAT) 30,000 (8.7) BTU/HR (KW/H) Min. LP 22,000 (6.4) BTU/HR (KW/H) Min. Nat. 19,500 (5.7) Height 27 3/4" (70.5cm) Width 25 1/2" (64.8cm) Depth 23" (58.4cm) Gas Inlet (Pipe) 1/2" (13mm) Floor to top of collar on vertical position of Vent Elbow 27 5/8" (70.2cm) Floor to center of collar on horizontal position of Vent Elbow 24 3/32" (61.2cm) Floor to Center of 90° elbow with a 24" length of pipe (see Figure 5) 55 1/2" (141cm) Stove Casting (Must be ordered with Firebox.) CIFB-1 Flat Black CIPB-1 Porcelain Black CIPG-1 Porcelain Green CIPS-1 Porcelain Sand CIPN-1 Porcelain Navy CIPR-1 Porcelain Red Accessories GWSG-T 750 Millivolt Wall Thermostat DVKH-1 Direct Vent Kit for Horizontal Run (Includes DVKA-1 Adapter) DVKV-1 Direct Vent Kit for Vertical Run (Includes DVKA-1 Adapter) DVKA-1 Direct Vent Kit Adapter FRBC-1 Battery Operated Remote Control FRBTC-1 Battery Operated Remote Control w/Thermostat FREC-1 Electric Remote Control FWS-1 Wall Switch CIB-2 Automatic Blower Stone Inlay Replaces Standard Grille Top CII-2 Stone Inlay Empress Green CII-3 Stone Inlay Hunan Jade CII-4 Stone Inlay Gray Botticino CII-5 Stone Inlay Azul CII-6 Stone Inlay Salome CII-7 Stone Inlay Black Swan THIS IS A HEATING APPLIANCE • Due to high temperatures the appliance s...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría