Refer to National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3. b. Vent room directly to the outdoors. Refer to National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3. c. Install a lower BTU/Hr heater, such as a 21,000 BTU/Hr, to make the area an unconfined space. If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, then the space is an unconfined space. You will need no additional fresh air ventilation for an unconfi ned space. COLD CLIMATE INSULATION For cold climate
• The individual manual shut-off must be a T-handle type valve. NEW YORK CITY APPROVAL New York City, NY (MEA) These fireplaces are approved for installation in New York City in the US state of New York if the following additional requirement is met: • An Outside Combustion Air Kit (FOAK-4, FOAK-4LD, or DK-4) must be installed. See Step 5 on Page 14. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS COLd C
Before the operation of the vent system can be tested, the lever securing screw must be removed (see Figure 20). The hand operated outside air control lever is located on the left side of the fi replace opening (see Figure 20). STEP 7. INSTALLING OUTSIDE AIR KIT Optional outside make-up air kits, Model FOAK-4 or FAOK-4LD (see Figure 21 on Page 14), may be used with these appliances. Refer to the installation instructions packaged with the air kits for specifi c installation information. If used,
WARNING: Risk of personal injury or property damage. To prevent glass door assembly from falling out, securely tighten latch screws when reinstalling. (Also see WARNING box on Page 1.) Step 7. If applicable, reinstall the mesh pull screen assembly removed in Step 1, as follows: a. Reattach both mesh pull screens to the rod. b. Insert the right side of the rod into the corresponding hole on the upper right side of the firebox opening. c. Insert the left side of the rod into the corresponding hole
A 04/2011 HEARTH PRODUCTS KITS AND ACCESSORIES NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 2 1 Montebello Series Andiron Kits Description Cat. No. Model Andiron Kit, Mission H2227 AKM-LSM Andiron Kit, Classic H2228 AKC-LSM WARNING: Burn hazard. Install only when fireplace is OFF and COLD. Step 1. If applicable, remove the mesh pull screens, as follows: Lift up the left side of the screen rod and slide it to the LEFT until the right side of the rod is disengaged from the hole. Slowly
A vacuum can be used to remove any dust accumulation on the blower’s blades or inside the blower duct. Caution should be used not to damage the blower’s blades during cleaning. To reinstall the blower, slide the blower back into the retaining lip B and retighten screws A. A Adjustable Hopper The Winslow™ PI40 insert is shipped with the 55 pound hopper. With the larger hopper installed, that part of the insert that slides into the fireplace is 22-1/2” (572 mm) high. For installations in smaller f
No. Model Description Model Series ARCH PANE DESIGN KITS H3970 APDL35C 35” Arch Doors, Charcoal ELDV35 H3971 APDL35SP 35” Arch Doors, Satin Pewter H3973 APDL40C 40” Arch Doors, Charcoal ELDV40 H3974 APDL40SP 40” Arch Doors, Satin Pewter H3976 APDL45C 45” Arch Doors, Charcoal ELDV45 H3977 APDL45SP 45” Arch Doors, Satin Pewter STYLE VIEW DOOR KITS Cat. No. Model Description Model Series ARCH PANE DESIGN KITS H6104 APDML30C 30” Arch Doors, Charcoal MPLDV30* H6105 APDML30SP 30” Arch Doors, Satin Pew
Wires for ON/OFF switch Switch Mounting Bracket on Doorframe Remove this lower panel by lifting it up and out. Figure 1 Figure 3 Tabs engage into slots (both sides) Hook Doorframe Over Glass door Slot Tab Fireplace Doorframe Locate the doorframe bracket on the lower front of the doorframe and lock it behind the cabinet bottom flange as shown here. Doorframe Bracket Figure 5 - MPLDV Models Detail Showing Glass Door Clip Being Put Into Place Between Doorframe And Glass Door Locate slot on each sid
b.Position the bottom of the doorframe so that the bracket on the inside of the doorframe locks behind the cabinet bottom flange as shown in Figure 4. *c. Feed the switch wires through the switch mounting bracket on doorframe as shown in Figure 3. Retain the lower panel for future use in case the Style View Door Kit is ever removed. Wires for ON/OFF switch Switch Mounting Bracket on Doorframe Remove this lower panel by lifting it up and out. Figure 1 Figure 3 Tabs engage into slots (both sides)