Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario HP, modelo HP BL860c Dual Processor Server Blade

Fabricar: HP
Tamaño del archivo: 273.12 kb
Nombre del archivo:
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


NOTE:
To avoid creating this adverse condition, the HP Integrity Essentials Foundation
Pack for Linux installer will not install the HP ACU-CLI (hpacucli) product on these
servers and this option is not displayed in the product installation menu. Further, if
hpacucli is detected on the system, it is uninstalled by the installer.
Workaround: If multiple logical drives are required on a given SmartArray controller, use
the ORCA utility at the EFI shell to configure them. Do not use hpacucli to configure these
storage devices. Alternatively, you can upgrade the OS to RHEL5U2.
THIS ISSUE WAS FIXED IN FOR THE RHEL5U2 RELEASE.

On a CoreIO P400 with an OS installed on it, the deleting array operation acts abnormally.
On HP Integrity servers, the operation to delete an array should be successful with or without
an OS installed. However, when the delete array operation is performed for an array on
CoreIO P400 controllers, the operation fails and the following error message is displayed
"Error: Could not delete array *".
Workaround: Deleting an array on CoreIO P600 controllers with an OS installed on operates
as expected.

hpacuscripting return code is not "0".
On HP Integrity servers running RHEL5.4, RHEL4.8, SLES10SP3, or SLES11SP1, run the
command "$hpacuscripting -i acuinput.ini -internal" on SmartArray
controllers or run "$hpacuscripting -i acuinput.ini -external" on FibreChannel
controllers to write configuration to the hardware, the return code is not "0", but "11". An
"error.ini" file will not be created.
Workaround: This error does not affect functionality.

hpacucli acts abnormal on rhel5.4Xen with Qlogic card and MSA1000/1500 storage.
On RHEL5.4xen, with hpacucli8.40+hp-fc-enablement-1.1-13 installed, use
hpacucli for show, create, or delete operations on MSA1000/1500 connected to
AB379A/AB379B (Qlogic card).
Workaround: On RHEL5.4, the hpacucli show/create/delete functions act normally.
Problems Resolved
The following issues have been resolved in previous releases of the HP ACU-CLI.

HP ACUCLI 8.25 installation encounter dependence issue on SLES10 and SLES11.
Installing ACUCLI8.25 on SLES10 and SLES11 will issue a "compat libstdc:: 296"
dependence issue.
THIS ISSUE WAS FIXED IN THE 8.28 RELEASE.
Workaround: For a SLES10 installation, skip the dependency check before the ACUCLI 8.25
installation. Use the command rpm -ivh hpacucli-8.25-5.ia64.rpm nodeps.
Workaround: For a SLES11 installation, install the file compat 2008.10.27
1.9.ia64.rpm before the ACUCLI 8.25 installation. Next, execute the command rpm
-ivh hpacucli 8.25-5.ia64.rpm nodeps. The file
compat-2008.10.27-1.9.ia64.rpm is included in the HPIEFPL 2.5 CD.

Migration of logical volume using an unsupported stripe size does not work.
THIS ISSUE WAS FIXED IN THE 8.28 RELEASE.
Attempts to migrate the stripe size of a logical volume to unsupported sizes results in no
error message.
Workaround: You should only migrate existing striping to supported sizes.
Problems Resolved
7


...

Otros modelos de este manual:
Computadoras - HP BL860c Single Processor Server Blade (273.12 kb)
Computadoras - HP Integrity BL860c Carrier-grade Server Blade (273.12 kb)
Computadoras - HP Integrity BL860c Server Blade (273.12 kb)
Computadoras - HP Integrity BL870c Server Blade (273.12 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría