Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Pentax, modelo R-326EX

Fabricar: Pentax
Tamaño del archivo: 1.2 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The procedure to adjust the reticle illumination is the same way as 4.3. • Pressing the Illumination key views the F3-RETICLE, F4-LCD and F5-ILLU. 5. ANGLE MEASUREMENT 5.1 Measuring an angle Aim at the first target, then press [F3] [0 SET] twice in succession to reset the horizontal angle to 0. H.angle H.dst. V.dst. 0° 00’ 00” MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 Aim at the second target, then read the horizontal angle. H.angle H.dst. V.dst. 60° 30’ 20” MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 Pressing [F4] [DISP] displays the vertical angle. H.angle H.dst. 60° 30’ 20” V.dst. 87° 05’ 40” MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 • The [0 SET] key cannot reset the vertical angle to 0. • Pressing the [DISP] key cycles through the sets of display items:“H.angle/H.dst./V.dst.”, “H angle/V.angle/S.dst.”, and “H.angle/V. angle/H.dst./S.dst./V.dst.”. • Even though you turn the power off during a survey, the horizontal angle displayed last time is saved, so that it is restored when the power is turned on next time. • When the restored horizontal angle is not necessary, reset it to 0. 5.2 Resetting the horizontal angle to 0 Pressing [F3] [0 SET] twice in succession resets the horizontal angle to 0° 0' 0". H.angle H.dst. V.dst. 0° 00’ 00” MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 • The [F3] [0 SET] cannot reset the vertical angle to 0. • Pressing the [F3] [0 SET] accidentally during measurement does not reset the horizontal angle to 0 unless you press it again. Once the buzzer stops sounding, you can go to the next step. • You can reset the horizontal angle to 0 any time except when it has been held. 5.3 Holding the horizontal angle To hold the horizontal angle currently being displayed, press [F3] [HOLD] twice in succession. The horizontal angle value is displayed in reverse video when being held. H.angle H.dst. V.dst. 130° 45’ 20” S.FUNC ANG SET HOLD CORR MODE MODE B 15°C S 0 • lf you want to hold the horizontal angle when you are in mode A, press [F5] [MODE] first to switch to mode B, then press [F3] [HOLD]. • The [F3] [HOLD] cannot hold the vertical angle or distance. • To release the horizontal angle from being held, press [F3] [HOLD] once. • Pressing [F3] [HOLD] accidentally during measurement does not hold the horizontal angle unless you press it again. Once the buzzer stops sounding you can go to the next step. 5.4 Inputting an arbitrary horizontal angle In case of Horizontal angle 123° 45' 20" input Press [F5] [MODE] to enter mode B. Press [F2] [ANG SET] to display the angle setting screen, then press [F4] [ ] to move the cursor to “2. H. ANGLE INPUT”. Press [F5] [SELECT] to open the horizontal angle input window. [F5] [CLEAR] is used to clear the values. H.angle H.dst. V.dst. 92° 30’ 20” S.FUNC ANG SET HOLD CORR MODE MODE B 15°C S 0 SELECT ANGLE SET 1. ANGLE / %GRADE: ANGLE 2. H. ANGLE INPUT: 092°30’20” 3. R/L REVERSE: RIGHT SELECT ANGLE SET 1. ANGLE / %GRADE: ANGLE 2. H. ANGLE INPUT: 92°30’20” 3. R/L REVERSE: RIGHT 0 9 2° 30’20” CLEAR ANGLE SET 1. ANGLE / %GRADE: ANGLE 2. H. ANGLE INPUT: 092°30’20” 3. R/L REVERSE: RIGHT • The 0% represents the horizontal 0, and +100% and -100% represent 45° up and down slopes respectively. • To return the screen from the slope (%) display to the 360° scale, also take above same steps by entering mode B. • If the slope (%) exceeds [+/-]1000%,“Out of grade range”is displayed,indicating that the current vertical angle cannot be measured. • When the telescope returns to a slope within slope [+/-] 1000%, the slope (%) display returns automatically from the “Out of grade range” message to the numeric value. 5.6 Changing the horizontal angle from clockwise to counterclockwise Press [F5] [MODE] to enter mode B. Press [F2] [ANG SET] to display the Angle setting screen. Press [F4] [ ] to move the cursor to “3. R/L REVERSE”. H.angle H.dst. V.dst. 92° 30’ 20” S.FUNC ANG SET HOLD CORR MODE MODE B 15°C S 0 1. ANGLE / %GRADE: ANGLE 2. H. ANGLE INPUT: 092°30’20” 3. R/L REVERSE: RIGHT SELECT ANGLE SET 1. ANGLE / %GRADE: ANGLE 2. H. ANGLE INPUT: 092°30’20” 3. R/L REVERSE: RIGHT ANGLE SET MODE A 15°C S 0 H.angle -267° 29’ 40” Press [F5] [SELECT] to add a minus sign (-) H.dst. to the horizontal angle value as a V.dst. counterclockwise angle. MEAS TARGET 0 SET DISP MODE • To return the horizontal angle from counterclockwise to clockwise, also take the above same procedures, press [F5] [SELECT] to select the clockwise angle. • When the counterclockwise horizontal angle is selected, the order of aiming at the targets becomes the reverse (the right one first, then the left one) of the order for the clockwise angle. 6. DISTANCE MEASUREMENT 6.1 Target setting The target mode and its Constant of current setting are shown at the left of the battery mark. For example in case of each Constant 0, Reflector sheet; S 0, Reflectorless (Non-Prism); N 0, Prism; P 0 H.angle H.dst. V.dst. MEAS TARGET 0 SET DISP MODE MODE A 15°C S 0 TARGET CHANGED (CONST.: 0mm) SHEET Pressing [F2][TARGET] changes ...

Otros modelos de este manual:
Instrumentos de óptica - R-315EX(NX) (1.2 mb)
Instrumentos de óptica - R-315EX(NX) (1.2 mb)
Instrumentos de óptica - R-322EX(NX) (1.2 mb)
Instrumentos de óptica - R-323EX(NX) (1.2 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría