10.1 Electronic vial [Checks] 1 Align the electronic vial in parallel with a line joining any two of the leveling screws. Then, adjust the two screws to center the bubble in the eelectronic vial. Turn two leveling screws in an opposite direction mutually and have the bubble of the side of the electronic vial to the center. Make the bubble of the length of the electronic vial to the center by operating the leveling screw of one remainder. Rotate the instrument by 180° and confirm the position of the bubble of the electronic vial. At this time, it is not necessary to adjust it if the bubble of the electronic vial is in the vicinity of the center. 4 3 2 Leveling screws Leveling screws • Please check the electronic vial in a steady environment that has no vibration or rapid temperature change. • When the electronic vial is checked outdoors and on a tripod, avoid sunlight influence by using a sunshade. Please wait for a while until the instrument and tripod are at the same temperature as the surrounding air. • When the instrument is seen at the position of “Left circle”, movement and the inclination of the instrument become the same on the screen in the electronic vial. Please note that the movement of the bubble becomes opposite direction if it is seen at the position of “Right circle”. [Adjustments] It is necessary to adjust as following when the bubble is not in the vicinity of the center in the confirmation of .4 [Procedure to adjust the electronic vial] Press the [POWER] and [LASER] key simultaneously. Following screen is viewed. Aim at a target and press [F3] key. Following screen is viewed. Turn the instrument 180° and reverse the telescope. Aim at the same target accurately, then press [F3]. Following screen is viewed. Pressing the [ENT] key completes the adjustment. F3 Electronic vial adj. Avoid direct sunlight and viration during adjustment. Aim at a target accurately, then press [F3] 0 SET F3 Electronic vial adj. Turn the instrument 180° and reverse the telescope. Aim at the same target accurately, the, press [F3] 0 SET F5 Electronic vial adj. Successfully accomplished. Press [ENT] 10.2 Circular vial Adjust by the electronic vial beforehand. Confirm the position of the bubble of the circular vial. At this time, it is not necessary to adjust if the bubble is at the center of the circle. [Adjustments] When the bubble of the circular vial comes off from the center according to check procedure , it is necessary to adjust. Turn the bubble adjustment screw with a hex wrench (L type wrench) and put the bubble in the center of the circle. [Only the detaching type model] Turn the bubble adjustment screws with the reticle adjustment pin and put the bubble in the center of the circle. [Checks] 2 1 2 • Tighten the screws equally after the above adjustment. Circular vial adj. screw Circular vial Circular vial adj. screw 10.3 Vertical reticle Set the instrument up the tripod and carefully level it. Sight the target Point A with telescope. Using the telescope fine adjustment screws, move Point A to the edge of the field of view by screw (Point A’). No adjustment is necessary if Point A moves along the vertical line of the reticle. Line of sight axis Vertical line [Checks] 4 3 2 1 [Adjustments] If Point A is off from the vertical line of the reticle, first remove the eyepiece cover. Using the adjusting pin, loosen the four reticle adjustment screws slightly loosening each screw by the same amount, and then rotate the reticle line around the sight axis and align the vertical line of the sight axis with Point A’. Tighten the reticle adjustment screws again by the same amount, and repeat the check to make sure the adjustment is correct. 3 2 1 . Since the R-322NX,R-322EX,R-323NX and R-323EX have triple axis compensation, it is necessary to make other settings besides the adjustments mentioned above. For details, contact the dealers from whom the instrument was purchased. Recticle adjusting screws Recticle adjusting screws 10.4 Perpendicularity of line of sight to horizontal axis Position a target Point A at a distance 30m - 50m away from the instrument, and sight it with the telescope. Loosen the telescope lock screw and turn the telescope until a point is sighted at a distance roughly equal to that of Point A. This is Point B. With the telescope still reversed loosen the horizontal lock screw and rotate the instrument around the vertical axis, and sight Point A again. Loosen the telescope lock screw and turn the telescope until a point is sighted at a distance equal to that of Point B. This is Point C. No adjustment is necessary if Point B and C are aligned. [Checks] 5 4 3 2 1 A 30-50m30-50m B D C 1 2 4 2 3 [Adjustments] 3 2 1 If Points B and C are not aligned, mark Point D at 1/4 the length of the BC, from Point C in the direction of Point B. Using the adjustment pin, rotate the reticle adjustment screws horizontally opposite each other (see preceding page), and move the reticle to sight Point D. Repeat the check and m...

Otros modelos de este manual:
Instrumentos de óptica - R-315EX(NX) (1.2 mb)
Instrumentos de óptica - R-315EX(NX) (1.2 mb)
Instrumentos de óptica - R-322EX(NX) (1.2 mb)
Instrumentos de óptica - R-323EX(NX) (1.2 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría