BOX 5580, Winona, MN 55987-5580, Phone: 507/454-5300, Fax: 507/452-4507 0600-0008-0000 Rev D $10.00 November 1995 Made in the U.S.A. Supersedes without change: W733-XSMN Rev D00 Contents Contents This manual is a supplement to the Series 733/734 Program Manual. It is for configuring, servicing and calibrating your control. Use this manual in conjunction with the Series 733/734 Program Manual and Data Communications manual. PageItem Chapter 1 3 Install and Wire the Series 733/734 3 Dimensions 3 P

Descargado: 0   Tamaño del archivo: 218 kb   Fabricar: Watlow Electric  
Categoría: Estación meteorológica
@name

mA Input High: Represents the high current calibration point for Zone 2, input nAHI 20mA. Applies only to thermocouple and process input. Only applies to Zone 2 inputs. Thermocouple Compensator: Used to calibrate the thermocouple reference tC compensator for units with thermocouple input. Input 0.00mV compensated through Type J reference compensator (32°F/0°C). 4-20mA Output Low (Zone 1): Represents the process output low current calibration point for Zone 1. Applies to 0-5VDC and 4-20mA outputs

Descargado: 3   Tamaño del archivo: 272 kb   Fabricar: Watlow Electric  
Categoría: Estación meteorológica
@name

The control mode is time proportioning with automatic reset. There is a front panel adjustment for the proportional band and internal adjustments for the auto reset on all models and for cycle time on the solid state and relay output models. Access to internal adjustments is available by loosening just one screw and pulling the controller out of the case. Analog meter indication is available in the form of a deviation meter or a direct reading meter. In addition, there are front panel mounted L.

Descargado: 4   Tamaño del archivo: 994 kb   Fabricar: Watlow Electric  
Categoría: Estación meteorológica
@name

IS SEC CYCLE TIME C = TIME PROPORTIONING 15°F BAND. 9 SEC CYCLE TIME D = TIME PROPORTIONING _25“F BAND. 5 SEC. CYCLE TIME OUTPUT LD MD KO A = 35A SPST 0 = 60A SPST G = 25A SPST B = 35A 2PST E = 60A 2PST H = 25A 2PST C = 35A 3PST F = 60A 3PST J = 25A 3PST UNE VOLTAGE 115 VAC 230VÄCT CONNECTIONS I - QUICK CONNECTS 2 = BARRIER STRIP SEÎPOT ASSEMBLY ~ i - INTFGftAL 2 = REMOTE ♦ SENSOR RANGE NO 600 = 50 TO 500"F 10 TO 260°C __TYPE J TC 601 = 50 TO IOOO”F 10 TO 538“C TYPE J T£_ 6