Therefore the user needs only one vibration pad under their pillow or mattress. Triggering Control Panel into Alarm Externally A manual fire alarm switch (e.g. a glass break type) can be used to get the control panel to turn on the vibration pad and strobe light. This is done by connecting the red and yellow wires, from the control panel, together, with the switch (or volt-free relay isolated contacts). The wires from the switch can be connected into the circuit at the pattress terminals. Note: This does not cause the smoke alarm to sound. Adding an Ei 128R Pattress with relay to the system The Ei 128R Pattress is used where volt-free relay contacts are required to signal to other equipment when one of the smoke alarms sense fire. For example the relay can be used to signal to a warden call system, or to turn on lights. This requires the system to have at least two smoke/heat alarms. The first smoke/heat alarm should be mounted on the pattress Ei 172/160 as described above. The second smoke / heat alarm, interconnected to the first, should be mounted on the relay pattress Ei 128R. When any smoke alarm senses fire the Ei 172/160 pattress will signal the control panel into alarm and the Ei 128R pattress will switch its relay contacts. (Note: The Ei 128R will not operate without a 230VAC mains supply). Power Requirements The typical currents at 230 VAC are Standby 10 mA Alarm 50 mA 56 5. Product Guarantee Ei Electronics guarantees this system for 5 years from the date of purchase against any defects that are due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and service, and does not include damage resulting from accident, neglect, misuse, unauthorized dismantling, or contamination howsoever caused. This guarantee excludes incidental and consequential damage. If this system should become defective within the guarantee period, it must be returned to the nearest address in this leaflet. It must be carefully packaged with the power switch on the control panel in the off position, and with the problem clearly stated along with proof of the date of purchase. We shall at our discretion repair or replace the unit. Do not interfere with the system or attempt to tamper with it. This will invalidate the guarantee, but more importantly may expose the user to shock or fire hazards. This guarantee is in addition to your statutory rights as a consumer. Manufactured by: Ei Electronics. Shannon, Co. Clare Ireland. Distributed by: Aico Limited. Mile End Business Park, Oswestry, Shropshire, SY10 8NN, U.K. © 2002 P/N B14698 Rev 1 7 ...
Otros modelos de este manual:Detector de incendios - Ei161 (125.25 kb)
Detector de incendios - Ei166 (125.25 kb)
Detector de incendios - Ei160 (125.25 kb)
Detector de incendios - Ei172 (125.25 kb)