Otros manuales para este modelo:
Resumen del manual
Microsoft SQL Server 2000
ZDB with IR
not supported
Oracle 9i 2
ZDB with IR
not supported
SAP/R3 4.6x 1, 3
ZDB with IR
not supported
SAP Brtools 6.10 1 , 6.20 1
ZDB with IR
not supported
1 The integration is implemented using the ‘backint’ functionality.
2 Oracle 9i includes all released versions of 9i: 9.0.x, 9.2.x, and so on.
3 This includes all revisions. For example, 4.6x includes 4.6B, 4.6C, 4.6D and so on.
The following is a list of supported volume managers:
Supported volume managers
Operating system
Volume manager
HP-UX
Windows
Logical volume manager (LVM)
supported
n/a
Disk manager 1
n/a
supported
1
Dynamic disks are not supported
Data Protector supports various alternate path solutions that are supported by the HP StorageWorks Virtual Array.
The following is a list of alternate path and multipathing solutions that are supported:
Supported alternate path solutions
Operating system
Alternate path solution
HP-UX
Windows
HP StorageWorks AutoPath
supported
supported
HP-UX LVM Alternate Links
supported
n/a
Supported backup topologies
SNAPA is designed to use different backup topology scenarios, without any user interference or special
configuration. Supported configurations are listed below:
1. One application system, one Virtual Array and one backup system.
2. One application host, multiple Virtual Arrays & one backup system.
3. Multiple application systems, one or multiple Virtual Arrays and one backup system – each application
needs to be backed up in a separate backup session. Multiple application systems cannot be backed up in
the same backup session.
4. Single-system configuration – both application and backup systems are the same physical system.
5. LVM mirror configuration – achieved either using campus cluster concept or by using LVM mirroring on a
system outside cluster.
Supported connectivity topologies
SNAPA also supports multiple connectivity topologies without the need for special configuration parameters or user
intervention. The only limitations for connectivity topologies are HP StorageWorks Virtual array internal connectivity
limitations. Supported connectivity topologies are listed below:
Supported connectivity topologies
Connectivity topology
Description
Alternate path
The SAN environment provides multiple paths to storage.
Fabric connect
VA is connected to the application and backup systems through FC switch.
Public loop connect
FC port on VA is configured for public loop and FC hub or switch has single port loop
emulation.
Private loop connect
FC port on VA is configured for private loop and FC hub or switch has single port loop
emulation.
2