Your Adcom dealer can help select the best cable for your needs. (See CONNECTING THE GFA-7000 for more information). O RR, LR, R, C, L Outputs The GFA-7000’s connections to the loudspeakers are made through high-grade, 5-way, gold-plated binding post terminals. There are two terminals for each speaker, which are colored RED for the positive (+) output and BLACK for the negative (-) output. The binding posts will accept a variety of connector types; the most secure and prevalent of these is th

Descargado: 0   Tamaño del archivo: 1 mb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name

All input and output signal connections should be made only with high quality, low capacitance, shielded cables following the recommendations in the Inputs and Outputs section of CONNECTING THE GFA-7705/07. Quick Connections For those of you who are in a hurry to hook up your amplifier into your system, we have included this quick-connection section. The wiring is straight forward and expeditious if you use the proper cables and follow this diagram exactly. If you have any difficulties or ques

Descargado: 1   Tamaño del archivo: 1 mb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name

' yCÔlVr GFA-7705 Et GFA-7707 S.A.F.E: HIGH CURRENT, MULTI-CHANNEL POWER AMPLIFIERS GFA-7705/07 Features • Precision-matched devices used throughout the signal path. • Independent power supplies for each channel. • Fewer gain stages improve signal reproduction accuracy. • Custom toroidal power transformer provides better regulation and greater peak current capability. • ADCOM-Universal pre-prepped chassis and internal power supplies for easy in-field upgradeability from 5 to 7 channel

Descargado: 4   Tamaño del archivo: 6 mb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name

This may be necessary if it is not possible to sit centrally between the speakers. In normal use leave in the central 'click' position. © ZONE 1 - Push the button in to activate the ZONE 1 preamp out sockets. With the button in the out position the ZONE 1 preamp out sockets are muted. © ZONE 2 - Push the button in to activate the ZONE 2 preamp out sockets. With the button in the out position the ZONE 2 preamp out sockets are muted. © HEADPHONES SOCKET - Accepts headphones rated between 8 ohms

Descargado: 4   Tamaño del archivo: 419 kb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name

These must be removed and the appropriate wood side cheeks fitted before the amplifier is first used. See page 5 for full details. 2. Please retain the carton and all packing materials provided with this equipment so that it may be repacked correctly if it ever becomes necessary to transport the unit or to return it for service. , 3. If servicing is required then the equipment should be properly packed and returned to the dealer from whom it was purchased. It is essential to include a covering

Descargado: 1   Tamaño del archivo: 419 kb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name

No speaker switching is provided on the amplifiers as this invariably will cause some degradation of the signal, however slight. If it is necessary to switch speakers we recommend that the main pair be wired directly to the amplifier wherever possible and that only the ‘extension’ speakers be switched. With both models it is possible to reduce the value of output fuse fitted in the amplifier in order to provide the best protection for both the speaker and amplifier. See page 7 for full details.

Descargado: 7   Tamaño del archivo: 3 mb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name@name@name@name

Always ensure that the volume control on your amplifier is set to minimum before starting these procedures. Bi-wiring your loudspeakers Bi-wiring improves the sound of your system because it divides the high and low frequency signal currents into separate speaker cables. This avoids signal distortions arising from the high and low frequency currents interacting with one another within a single cable, as in conventionally wired systems. You will need: Speakers – with four input terminals each: th

Descargado: 2   Tamaño del archivo: 1 mb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name@name@name

MONO LINK 6. The P75 can be adapted to provide two mono loudspeaker outputs from a single input. Pull out the U-link 8 supplied and use it to connect the MONO LINK sockets 6 together. Utilising one P75 power amplifier per loudspeaker will enable you to bi-amplify bi-wireable loudspeakers. This is particularly beneficial for top quality stereo installations with a separate preamplifier, or for the left, centre and right channel loudspeakers in a five speaker Dolby Pro Logic™ or Dolby Digital™ sys

Descargado: 11   Tamaño del archivo: 919 kb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name@name@name@name@name

< Are all the channel-indicator LEDs on the front panel green? Refer to the table on page 10 if you see other colours. Hum on an amplifier output If you have a “hum” coming from one of the speakers, please check the following items. < Does the hum originate from a ground loop caused by an aerial, satellite dish or cable supply (if the aerial is disconnected, does the humming stop)? Please contact your dealer or aerial contractor for further advice. < Ensure that the interconnect and speaker lead

Descargado: 0   Tamaño del archivo: 1 mb   Fabricar: Adcom  
Categoría: El receptor y el amplificador
@name

22k. Signal/noise ratio (CCIR) –113dB –110dB Power amplifier input Nominal sensitivity 800mV 906mV (Arcam gain) Input impedance 22k. 22k. Gain 31.5dB 31.5dB (Arcam gain) Preamplifier output Nominal output level 700mV Maximum output level 8V RMS Output impedance <50. Headphone output Maximum output level into 600. 5V Output impedance 4.7. General Mains voltage 115V or 230V 115V or 230V 115V or 230V Power consumption (maximum) 30VA 800VA (950VA for P35/3) 800VA Power consumption (standby) 2VA 2VA