Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario HP, modelo HP DL380 - WSS Clustered Gateway

Fabricar: HP
Tamaño del archivo: 780.41 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


Chapter 3: Event Messages
36
ID
Message and Corrective Action
17005
This cluster is unable to take control of SAN, because the servers are unable
to perform fencing operations, possibly due to a networking or fencing
hardware failure or misconfiguration. As a result, some or all filesystem
operations may be paused throughout the cluster. In addition, filesystem
mounts and unmounts and disk imports and deports can not be performed.
Action. HP Clustered File System is unable to exclude servers that have
become unresponsive, or to verify the fencing of servers that were
previously fenced and have not yet been rebooted. Possibly the fencing
device is not responding to the fencing request or the Ethernet connection to
the FibreChannel switch has failed. Also check for other networking or SAN
hardware problems. The servers should be rebooted as soon as possible.
17006
This cluster takes control of SAN failure resolved.
Action. None. Alert 17005 is resolved.
17007
This cluster unable to take control of SAN, because the servers are unable to
write to a majority of the membership partitions, possibly due to a SAN
hardware failure or misconfiguration and/or because some servers have
been excluded from the SAN. As a result, some or all filesystem operations
may be paused throughout the cluster. In addition, filesystem mounts and
unmounts and disk imports and deports cannot be performed.
Action. Check the cluster configuration and add the server if it is not
currently a member. Also ensure that the server can access the membership
partitions and has write access to them, and check for any SAN hardware
problems.
17008
This cluster takes control of SAN failure resolved.
Action. None. Alert 17007 is resolved.
17009
This cluster unable to take control of SAN, because a majority of the
membership partitions cannot be written or are corrupt, possibly due to a
SAN hardware failure or misconfiguration and/or because servers have
been excluded from the SAN. As a result, some or all filesystem operations
may be paused throughout the cluster. In addition, filesystem mounts and
unmounts and disk imports and deports cannot be performed.
Action. Ensure that all servers can access the membership partitions and
have write access to them. If a membership partition is corrupt, another alert
will specify its location. See “Membership Partitions” in the HP StorageWorks
Clustered File System Administration Guide
for corrective actions.


...

Otros modelos de este manual:
datos de dispositivos de procesamiento - HP DL380-SL Clustered Gateway (780.41 kb)
datos de dispositivos de procesamiento - HP ProLiant DL380G5-WSS Storage Server Clustered Gateway (780.41 kb)
datos de dispositivos de procesamiento - HP ProLiant DL380G5-WSS Storage Server Initial Cluster (780.41 kb)
datos de dispositivos de procesamiento - HP 3PAR StoreServ File Controller v2 Storage (780.41 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría