Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario HP, modelo HP StorageWorks Director 2/64 base 32 port config

Fabricar: HP
Tamaño del archivo: 213.08 kb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere


Otros manuales para este modelo:

Resumen del manual


Element Manager user guide for more information. Embedded Web Server (EWS)
also provides an option to print or save product configuration to a file. Refer to the
HP StorageWorks Embedded Web Server User Guide for more information.
Al products must be running firmware 06.00.00 or later before upgrading to
07.00.00-84. If a switch is operating with a firmware level earlier than 06.00.00, you
must upgrade to 06.xx.xx before installing 07.00.00-84.
Upgrades and downgrades are supported only from one major release to the next, such
as from 06.xx.xx to 07.00.00-84. If EWS is used for upgrades and downgrades, and
this rule is not followed, errors occur and there may be a disruption to at ached devices.
If upgrading to firmware 06.02.00-22 requires you to upgrade from 04.xx.xx to
05.xx.xx in the process, there are special considerations:
• For directors, refer to Upgrading firmware on a director from 04.xx.xx to
05.xx.xx
• For edge switches, refer to Upgrading firmware on an edge switch from 04.xx.xx
to 05.xx.xx
A small number of early-shipped Surestore Director FC-64 units may receive one of the
following messages when they upgrade to firmware 05.02.00-13:
• HAFM—Firmware cannot be loaded due to insufficient CTP memory.
• EWS—File System Error: Insufficient memory for new firmware version.
This occurs only in certain units with CTP cards. Units with CTP2 cards do not have
this issue.
If you get one of these messages during the upgrade, the firmware upgrade failed, but
the unit continues working with the existing firmware without an interruption in service.
The upgrade process checks for sufficient memory before activating the new firmware
image. The firmware upgrade does not complete without sufficient memory. Please
contact HP Customer Support if you receive this message.
Some customer environments use application or host software that is affected by the
restart of the director CTP during a HotCAT download operation. Applications that rely
on inband management servers are especially prone to problems caused by processor
restart. For example, an application may be configured to pol the director or switch
at regular intervals. The polling process could occur during a restart period, causing
the application software to react adversely. As a solution, shut down those applications
driving inband requests during a firmware upgrade, then restart the applications after
upgrade completion.
Upgrading firmware on an edge switch from 04.xx.xx to 05.xx.xx
An issue has been identified in release 04.xx.xx if the contents of the nonvolatile storage
(NVRAM) on the CTP become corrupted. Once the configuration has been loaded,
this corruption is not detected until an IPL/IML, power cycle, or firmware code load.
If the NVRAM in the CTP has corrupted contents, the firmware load can cause the
configuration to reset to factory defaults, which could cause a system outage.
HP StorageWorks HA-Fabric Manager release notes
9


...

Otros modelos de este manual:
datos de dispositivos de procesamiento - HP StorageWorks Director 2/140 (213.08 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/12 (213.08 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/24 (213.08 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/32 (213.08 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría