Iniciar sesión:
Votos - 5, Puntuación media: 4.4 ( )

Manual de usuario Bosch, modelo DS422I

Fabricar: Bosch
Tamaño del archivo: 144.21 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


A reduction in the system’s effectiveness will occur if the units are not properly aligned and fine-tuned. Page 2 © 2004 Bosch Security Systems DS422i/426i Installation Instructions Transmitted Beam Transmitted Beam strength is strongest along this path Transmitted Beam weakens farther from its center Receiver's Line-of-Sight Figure H - Beam Strength Area Transmitted Beam Transmitted Beam strength is strongest along this path Transmitted Beam weakens farther from its center Receiver's Line-of-Sight Figure H - Beam Strength Area • Set the meter to read 3 to 5 VDC. • Fine peak the transmitter. Connect the meter to the receiver’s test terminals (see Figure J). NOTE: Observe the Polarity due to DC voltage. Figure J - Meter connection LEVEL + -1 2 3 4 5 RESPONSE TIME RECEIVER • Rotate the transmitter’s optical module very slightly to the right and left until a maximum meter reading has been achieved. If you cannot obtain a reading greater than 2.3 VDC, the Transmitter and Receiver must be realigned using the procedure in section 5.0. NOTE: To aid in fine-tuning the system, the red LEVEL LED gets brighter as the units get fine-tuned and the green GOOD LED will be on when the meter readings reach a peak. • Adjust the transmitter’s Vertical Fine Tuning screw slightly until maximum meter readings have again been achieved. • With the transmitter’s optical module fine-tuned, repeat this exact process with the receiver. 7.0 Final Check • Completely block the upper beam on the transmitter. Neither the ALARM LED nor the LEVEL LED should come on. If either does come on, the beams are incorrectly aligned (see Figure K) and should be re-aligned. Figure K - Mis-aligned beams •Completely block the lower beam of the transmitter. Again, neither the ALARM LED nor the LEVEL LED should come on. •If necessary, re-align and fine-tune each unit. 7.1 Alarm response time The system’s sensitivity to alarms is manually adjusted by the RESPONSE TIME Control on the receiver (see Figure L1 and Table L2). LEVEL + 1 2 3 4 5 RESPONSE TIME RECEIVER Figure L1 - Response Time Control Response Time Control SETTING RESPONSE TIME (ms) RESPONSE SPEED CATCH EXAMPLE 1 50±25% 23 ft./s (7 m/s) running 2 210±25% 4 ft./s (1.2 m/s) jogging 3 380±25% 2.3 ft./s (0.7 m/s) quick walk 4 540±25% 1.6 ft./s (0.5 m/s) walking 5 700±25% 1 ft./s (0.3 m/s) slow walk Table L2 - Response Settings A setting near 1 will alarm if a person runs through the beam while a setting near 5 will alarm for objects moving very slowly through the beam. The setting should be adjusted lower where birds, debris, etc., may interrupt the beam path. Be careful not to adjust the setting too low, or it will not trigger an alarm. NOTE: In order to comply with the requirements in UL 639, Intrusion Detection Units, an object passing through the beams at a speed of 8.8 feet per second (2.7 m/s) must trigger an alarm. • Walk through the beams after the desired setting has been chosen. Be sure the system alarms at the desired pace. • Walk through the beams in several locations between the units (see Figure M). • The system should alarm during each crossing of the beam. If not, re-check alignment or trigger response time. Figure M - Walk testing the • Replace the covers. system NOTE: If a tamper circuit has been installed, it should be tested now by lifting up the appropriate covers. • Secure the covers by tightening each cover mounting screw. 8.0 Other Information 8.1 Alignment Lights Alignment may be made easier by using a flashing high intensity light placed in front of the units. This makes a very distinct target when looking at the other unit through the viewing port. A recommended light source is model AL402. 8.2 Maintenance At least once a year the front covers should be cleaned. Use a clean cloth and a common window cleaner. On a daily basis, the end user should walk through the beams before arming. This will verify operation. DS422i/426i Installation Instructions © 2004 Bosch Security Systems Page 3 9.0 Application Tips When using photoelectric detectors for motion detection, there are a few installation techniques that will make the system more versatile. 9.1 Beam Stacking Beam stacking gives a wall of protection by stacking several units at different heights and providing an alarm activation on the blockage of only one pair of beams (see Figure N for the correct set-up technique). Note that the system is installed with alternating transmitters and receivers at each end. This eliminates the possibility of a receiver being covered by more than one transmitter. S Figure N - Beam stack method T1 R2 R1 T2 D The maximum spacing between receivers (S) can be calculated by dividing the distance between the transmitter and its receivers (D) by 20. Therefore, if the distance between a transmitter and receiver is 100 ft. (30 m), the maximum spacing between receivers would be 100 ft. (30 m) . 20, or 5 ft. (1.5 m) S = D/20 S = 100 ft. (30 m)/20 S = 5 ft. (1.5 m) A potential problem when installing syst...

Otros modelos de este manual:
Vídeo - DS426I (144.21 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría