Descargado: 2   Tamaño del archivo: 152 kb   Fabricar: Lifebreath  
Categoría: Aire
@name

If they do not operate continuously, then interlocking them electrically with the TFP is acceptable. Consult a certified electrician. WHOLEHOUSE AND PORTABLECONSOLE MODELS ATTENTION The TFP can be installed in several different ways. Please read all suggested methods before attempting installation. Electrical The TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch. * LEAVE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratin

Descargado: 2   Tamaño del archivo: 152 kb   Fabricar: Lifebreath  
Categoría: Aire
@name

4. A short piece (1-2 foot) of flexible ducting should be used on both sides of the TFP (Fig. 3). This will reduce vibration and noise transfer if present. NOTE: Please refer to the HRV installation manual for proper ducting of that appliance. Type 2 Installation *“Breathing T” is designed to assist in neutralizing pressure differences which can occur between HRV and TFP when joined together. TFP Hanging straps (4) Relief opening (breathing T) 6" port collars Power cord Flexible ducting Air flow

Descargado: 3   Tamaño del archivo: 99 kb   Fabricar: Lifebreath  
Categoría: Aire
@name

If they do not operate continuously, then interlocking them electrically with the TFP is acceptable. Consult a certified electrician. ATTENTION The TFP can be installed in several different ways. Please read all suggested methods before attempting installation. Electrical The TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch. C US * LEAVE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratings and dimensions are subject to

Descargado: 2   Tamaño del archivo: 99 kb   Fabricar: Lifebreath  
Categoría: Aire
@name

(Fig. 3) MOUNTING 1. Locate mounting bolts (4) on side of TFP cabinet for vertical hanging (Fig. 3) and remove. 2. Measure distance between the bolts and mark it on the floor/header joist where the TFP is to be hung. 3. Fasten hanging straps to floor joists using wide head nails or screws with washers. 4. Insert hanging bolts through prepunched holes in straps and lift TFP into position. Tighten and secure bolts. DUCTING 1. Install (2) 7” port collars (provided) on TFP cabinet with (8) 8/32” X 3

Descargado: 0   Tamaño del archivo: 45 kb   Fabricar: Lifebreath  
Categoría: Aire
@name

Included in the box are 4 wheels, a handle and screws to install the wheels and handle. You will need a 1/4” nut driver and a Phillips screw driver. The unit has a low/off/high switch located on the backside of the unit. As each home has differences of size, occupancy, location, infiltration rates and homeowner needs, it is hard to estimate when the collectors will need to be changed. Because of the way air moves through the TFPC, the collectors are divided into 3 separate sections. Collectors

Descargado: 3   Tamaño del archivo: 1 mb   Fabricar: Lifebreath  
Categoría: Aire
@name

Clean Core Twice a Year a) open access door. b) carefully grip ends of core and pull evenly outward. Core may be snug, but will slide out of the channel c) once removed from the cabinet remove filters d) wash core in warm soapy water (do not use dishwasher) e) install the clean filters f) install clean core Note: Core installation label on the outer end of the core. To install the clean core: a) first mount the bottom flange of the core guide into the bottom H channel approximately 1/4” (6mm) b)

Descargado: 15   Tamaño del archivo: 1 mb   Fabricar: Lifebreath  
Categoría: Aire
@name

DIRECT CONNECTION of both the HRV/ERV SUPPLY AIR STREAM and EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN RETURN AIR *Unit is normally balanced on HIGH speed with furnace blower ON. 40" (1m) MINIMUM O O Outdoors Cool Air Return NOTES: 1. Furnace blower may be required to operate when ventilation from HRV/ERV is required. The furnace should be set to run continuously or interlocked with HRV/ERV. 2. A minimum separation of 40 inches (1 m) is required between the two direct connections. 3. The

Descargado: 1   Tamaño del archivo: 1 mb   Fabricar: Lifebreath  
Categoría: Aire
@name

• Control Pad can be removed and mounted in a remote location. • Control Pad mounts in a 2”x 4” box or can be mounted in the optional Ventilation Dehumidistat or Air Sentry. • Full fan speed control. DIGITAL ELECTRONIC TIMER (DET) LOCATION: Bathrooms & kitchen • Connect up to 8 on 300' (91 m) wire max. • If a PVC or Air Sentry is used, connect up to 5 on 300' wire max. • Touch pad operation. • 20/40/60 minute status lights. • Compact wall mount unit. • Mounts in 2x4 box. • Shown with “decora” co

Descargado: 5   Tamaño del archivo: 2 mb   Fabricar: Lifebreath  
Categoría: Aire
@name

A good bead of high quality caulking (preferably acoustical sealant) will seal the inner flexible duct to both the HRV/ERV port and the weatherhood prior to clamping. To minimize air flow restriction, the flexible insulated duct that connects the two outside weatherhoods to the HRV/ERV should be stretched tightly and be as short as possible. Twisting or folding the duct will severely restrict air flow. See below for the recommended connection of flexible insulated ducts to the the outside weathe

Descargado: 5   Tamaño del archivo: 1 mb   Fabricar: Lifebreath  
Categoría: Aire
@name

• Mounts in 2x4 box. • Shown with “decora” cover plate (99-107W). PART NO. 99-104 Connects to RED, GREEN and YELLOW terminals. PROGRAMMABLE VENTILATION CONTROLLER (PVC) LOCATION: Hallway, kitchen, office & work place (connect 1/unit only) • Advanced digital remote. • Digital dehumidistat. • Full fan speed control. • AIR SENTRY™ Air Quality Sensor built-in. • Recirculation mode (on compatible HRV/ERVs). • 7 day, 24 hour programmable timer. • Digital display and status lights. • 100' (30 m) maximu