Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Napoleon Fireplaces, modelo VF4000-CHN-2

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 1 mb
Nombre del archivo: Lennox_Superior_VF-4000_Installation_Operation_903590.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Note:The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence. CAUTION: HEATERS CREATE WARM AIR CURRENTS. THESE CURRENTS MOVE HEAT TO WALL SURFACES NEXT TO HEATER. INSTALLING HEATER NEXT TO VINYL OR CLOTH WALL COVERINGS OR OPERATING HEATER WHERE IMPURITIES IN THE AIR (SUCH AS TOBACCO SMOKE) EXISTS, MAY DISCOLOR WALLS. Step 1. Position heater in desired location (freestanding, onto surround base or into prepared framing) and secure. Step 2. Plumb gas line. (Gas connections should only be performed by an experienced, licensed/ certified tradesman.) Step 3. Assemble logs and test flame appearance. Step 4. Complete finish wall material, surround and optional hearth extension to your individual taste. INSTALLATION STEPS Built-In Systems WARNING: DO NOT ALLOW FANS TOBLOW DIRECTLY INTO THE FIREPLACE. AVOID ANY DRAFTS THAT ALTERBURNER FLAME PATTERNS. WARNING: DO NOT USE A BLOWER IN- SERT, HEAT EXCHANGER INSERT OROTHER ACCESSORY NOT APPROVEDFOR USE WITH THIS HEATER. Do not burn solid fuels in this listed unvented gas room heater. Step 1. Frame VF4000 appliance enclosures as illustrated in Figures 4, 5 and 6. Note:The framed depth (15-1/2" for a flat wall, 29" for a corner VF4000) must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the dimension must be measured from the drywall surface. Note:Framing dimensions in Figures 4 - 6 are calculated for a nailing flange depth of 1/2" (13 mm). Figure 437" (940mm) 15-1/2" (394mm) Outside WallMaterials If Any. Figure 437" (940mm) 15-1/2" (394mm) Outside WallMaterials If Any. f Chase/EnclosureIncluding Finishing Back Wall of 37-1/4" (946 mm) 37" (940 mm) 15-1/2" (394 mm) Figure 537" (940mm) 58-1/2" (1486mm) 13-1/2" (343mm) 29" (737mm) 41" (1041mm) Chase/EnclosureIncluding FinishingMaterials If Any. Figure 6 Step 2. Route a 1/2" (13 mm) gas line along the left or right side framing (Figure 7). All appliances have a 3" long 3/8" NPT nipple installed at the regulator. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV. Step 3. Position appliance into prepared framing, secure with 6d nails at the nailing flange along each side. Step 4. Connecting Gas Line – Make gas line connections. All codes require a shut-off valve mounted in the supply line.Figure 8illustrates two methods for connecting the gas supply. Installation methods and materials must be in compliance with local codes. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. The gas control valve is located in the lowercontrol compartment. To access the valveopen the lower control compartment door(Figure 9). The regulator has a 3/8" NPT thread inlet portand is fitted with a 3" (76 mm) long nipple,..." NPT on both ends. Plan the connections ac- cordingly. We recommend that the gas line be routed forthe right side of the appliance to e...

Otros modelos de este manual:
chimeneas - VF4000-CHN-2 (1 mb)
chimeneas - VF4000-CHP-2 (1 mb)
chimeneas - VF4000-CHN-2 (1 mb)
chimeneas - VF4000-CHN-2 (1 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría