Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Napoleon Fireplaces, modelo VF4000-CHP-2

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 1 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Plan the connections ac- cordingly. We recommend that the gas line be routed forthe right side of the appliance to ensure ad- equate access to the rear lower compartmentfor installation and servicing of the optionalFAB-1100 blower. Figure 8Figure 9Secure all joints tightly using appropriatetools and sealing compounds (ensure pro- pane resistant compounds are used inpropane applications). Turn on gas supply and test for gas leaks, using a gas leak test solution (also referred toas bubble leak solution). Note: Using a soapy water solution (50% dishsoap, 50% water) is an effective leak testsolution but it is not recommended, becausethe soap residue that is left on the pipes/ fittings can result in corrosion over time.Neveruse an open flame to check for leaks. 3" (76 mm) 7" (178 mm) Figure 7Gas Stub1/2" x 3/8" FlareShut-Off Valve3/8" Flex Tubing3/8" NPT x 3/8" Flare Fitting3/8" Nipple, Standardwith all Units3/8" Union3/8" Close Nipple3/8" Shut-Off Valve1/2" x 3/8" ReducerGas ValveGas Flex Line Kit, Model GFLVControlValve(Standard) Lower ControlCompartment Door A. Light the appliance (refer to safety and lighting instructions on pages 14 and 16). B. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the gas control knob to the “OFF” position. Either tighten or refasten the leaking connection and retest as described above. C. When the gas lines are tested and leak free, be sure to rinse off the leak testing solution. D. When the gas lines are tested and leak free, observe the individual tongues of flame on the burner. Make sure all ports are open and producing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports. An external regulator must be used on all propane (L.P.G.) heaters, in addition to the regulator fitted to the heater, to reduce the supply tank pressure to 13" w.c. (maximum). WARNING: CONNECTING DIRECTLY TOAN UNREGULATED PROPANE TANK CANCAUSE AN EXPLOSION. Step 5. Installing the Optional Remote Wall Switch (VF4000-CMN/P models only) – The millivolt system comes from the factory wired as shown in Figure 10. Select a convenient location for the remote wall switch and connect the wiring to the appliance (Figure 11). CAUTION: DO NOT CONNECT THE OPTIONAL REMOTE SWITCH TO A 120V POWER SUPPLY. Note:The optional rocker switch is mounted to the appliance and wired in the same way as the remote wall switch. VF4000-CMN/P Series Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. TPTHTPTHThermopile** From Thermocouple NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.7Figure 12White(Supply) Black(Supply) BipolarTerminalScrewBlower(Lower) OutletBlackWireMatingConnectorsRed Wire120 Vac 60 HzBlower Wiring Diagram} OFF/ON BlowerWall SwitchTo Fuse orCircuit Breaker120VAC60HzFireplaceJunction BoxBlackWhiteReceptacleGround WireConnectionNote: Supply wires may b...

Otros modelos de este manual:
chimeneas - VF4000-CHN-2 (1 mb)
chimeneas - VF4000-CHP-2 (1 mb)
chimeneas - VF4000-CHN-2 (1 mb)
chimeneas - VF4000-CHN-2 (1 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría