Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Napoleon Fireplaces, modelo VF4000-CMP-2

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 1 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Refer to Figure 13 for floor and platform installations. If the heater is to be installed into a framed wall refer to the built-in assembly steps beginning on page 5. Figure 13 Note:The heater may be installed directly on a floor made of standard combustible wood construction materials. Do not install the heater directly on carpeting or other soft floor covering such as vinyl tile or flooring materials. Use a wood or metal panel that extends the full width and depth of the heater between the heater and any soft floor covering material. Refer to Figure 20 for base dimensions. Step 8. Secure Heater – Bend the tabs down (Figure 13 ). Using two (2) screws securely tighten the appliance to the platform. Note:Heater must be anchored to the floor or platform. Step 9. Install Optional 120V Wiring –Refer to Step 6 for wiring instructions. Connecting Gas Line Step 10. A qualified gas appliance installer must connect the gas room heater to the gas supply. Consult all local codes and refer to Step 5. The heater gas inlet connection is 3/8" NPT, located on the right side facing the heater. If a left side connection is required, route the gas line under the valve to end at the right hand side for connection to the inlet. This may be required to allow for installation of the blower. When tightening up the joint to the valve hold the valve securely with a wrench to prevent the valve from moving. Step 11 . For Surround Installations Only – Finish the assembly of the surround components and secure the surround to the appliance. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Assembling the Logs WARNING: DO NOT ADD EXTRA LOGS ORORNAMENTS SUCH AS PINE CONES, VER- MICULITE OR ROCK WOOL. USING THESEADDED ITEMS CAN CAUSE SOOTING. WARNING: DO NOT PLACE ANY LAVAROCK ON LOGS OR BURNERS. THIS MAYCAUSE SOOTING. Step 12. The heater includes a unitized set of ceramic fiber logs. The heater and logs are assembled as shown in Figure 14. Handle these logs with great care. The logs can be easily damaged, but when handled properly they can provide years of performance and enjoyment. Figure 14 After setting the logs into position as described above, ensure they are properly and firmly situated. The heater will not function as intended if the logs are not correctly positioned. Periodically check the positioning of the logs. WARNING: FAILURE TO POSITION THEPARTS IN ACCORDANCE WITH THESEDIAGRAMS OR FAILURE TO USE ONLYPARTS SPECIFICALLY APPROVED WITHTHIS HEATER MAY RESULT IN PROP- ERTY DAMAGE OR PERSONAL INJURY. Flame Appearance REFER TO THE OPERATING INSTRUCTIONS LOCATED AT THE BACK OF THIS MANUAL BEFORE LIGHTING THE HEATER TO OBSERVE THE FLAMES. Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition a periodic visual check of the flames should be made. The pilot flame should always be present when the heater is in operation and should just envelope the tip of the thermocouple (Figure 15). WARNING: NO ADJUSTMENTS ARE TOBE MA...

Otros modelos de este manual:
chimeneas - VF4000-CHN-2 (1 mb)
chimeneas - VF4000-CHP-2 (1 mb)
chimeneas - VF4000-CHN-2 (1 mb)
chimeneas - VF4000-CHN-2 (1 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría