Resumen del manual


Venting with Two 90° Elbows H1 H V V V1 H NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 900 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 900 Elbow on top 2’ MAX. (610mm) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H + H1 = 50’ MAX. (15.2m) NATURAL GAS VENTING WITH TWO 90° ELBOWS V + V1 (FT.) H (FT.) 900 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + V1 + H = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V + V1 (FT.) H (FT.) 900 Elbow on top 2’ MAX. (610mm) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + V1 + H = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 27 Figure 16. Venting with Two 90° Elbows Figure 17. Venting with Two 90° Elbows H1 V H V H H1 NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H + H1 = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H + H1 = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) 28 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 Figure 18. Venting with three 90° elbows H H1 H2 V H V H1 V1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 + H2 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V+ V1 + H + H1 + H2 = 50’ MAX. (15.2m) PROPANE VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 + H2 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V+ V1 + H + H1 + H2 = 50’ MAX. (15.2m) H + H1 + H2 = 18’ MAX. (5.5m) H + H1 + H2 = 12’ MAX. (3.6m) NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V+ V1 + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V+ V1 + H + H1 = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 29 Figure 19. Venting with three 90° elbows V H H1 V1 V H H1 V 1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 900 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V+ V1 + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 900 Elbow on top 2’ MAX. (610mm) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V+ V1 + H + H1 = 50’ MAX. (15.2m) H + H1 = 12’ MAX. (3.6m) H + H1 = 18’ MAX. (5.5...

Otros modelos de este manual:
chimeneas - LCOR-HV-IPI (3.11 mb)
chimeneas - PIER-HV-IPI (3.11 mb)
chimeneas - ST-HV-IPI (3.11 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría