Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Fujitsu, modelo AUU18RC

Fabricar: Fujitsu
Tamaño del archivo: 708.5 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


. If dirt is allowed to accumulate on the air filter, air flow will be reduced, lowering operating efficiency and increasing noise. . During periods of normal use, the air filters should be cleaned every two months. ERRORS AND SELF DIAGNOSIS TIMER MODE ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE Error Code If there is a problem with the air conditioner, it will stop running and “E: EE” will be displayed instead of the clock. (1) If the operation lamp is on then press the START/ STOP button to turn it off. (2) Press the SET TIME (Ў) and the TEMP./DAY (Ў) buttons at the same time for more than three seconds to start the self diagnosis check. An error code will be displayed in the clock display area. (3) Press the SET TIME (Ў) and the TEMP./DAY (Ў) buttons again for more than three seconds to end the self diagnosis check. Error Code Error contents st Communication error (indoor unit remote controller) st Communication error (indoor unit outdoor unit) Room temperature sensor open Room temperature sensor shortcircuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperature sensor shortcircuited Outdoor heat exchanger temperature sensor open Outdoor heat exchanger temperature sensor shortcircuited Power source connection error Float switch operated Outdoor temperature sensor open Outdoor temperature sensor shortcircuited Discharge pipe temperature sensor open Discharge pipe temperature sensor shortcircuited Outdoor high pressure abnormal Discharge pipe temperature abnormal Model abnormal Indoor fan abnormal Outdoor signal abnormal Outdoor EEPROM abnormal En-14 OPERATION DETAILS Instructions relating to heating(*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Please read and understand the following details regarding this air conditioner. Operation and Performance * Heating Performance . This air conditioner uses a heat pump which absorbs heat from outside air and brings it indoors. As a result, its heating performance is reduced as the temperature of outside air drops. If you find that insufficient room heat is produced, we recommend that you use the air conditioner together with other heating appliances. . Heat-pump type air conditioners use warm-air recirculation to warm your entire room. As a result, some time will be required after starting operation until your entire room becomes warm. * When Indoor and Outdoor Temperatures are High When both indoor and outdoor temperatures are high during use of the heating mode, the outdoor unit’s fan may stop at times. * Microcomputer-controlled Automatic Defrosting When the outside temperature is low and the humidity high, frost will collect on the outside unit, reducing heater efficiency. When this happens, the computer will automatically start the defrost cycle. During the defrost cycle, the indoor fan will shutdown and DEFROST will be displayed on the remote controller. It will take anywhere from 4 to 15 minutes before...

Otros modelos de este manual:
Los acondicionadores de aire - AOU18RC (708.5 kb)
Los acondicionadores de aire - AUU36RC (708.5 kb)
Los acondicionadores de aire - AUU42RC (708.5 kb)
Los acondicionadores de aire - AOU18RC (708.5 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría