Iniciar sesión:
Votos - 0, Puntuación media: 4 ( )

Manual de usuario Yamaha, modelo PM5D

Fabricar: Yamaha
Tamaño del archivo: 130.17 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


If this option is on, and HA (head amp input sensitivity) is selected as the encoder mode, you can use the ENCODER [ON] key located above each encoder to turn phantom power supply (+48V) on/off. Switch parameter value indication on/ off in the Name display (from V1.05) A “CHANNEL NAME NUMERIC DISPLAY” field has been added to the PREFERENCE 2 screen. In V1.04 and earlier, operating the fader or encoder (pan setting) of each channel caused the name display to show the value of that parameter. In V1.05 and later, turning the “ENCODER VALUE” and “FADER VALUE” options off will prevent the respective parameter value from appearing when you operate the fader or encoder. Select the monitor source from the panel (from V1.05) When selecting a monitor source from the panel in V1.04 or earlier, you could simultaneously select one source from [2TR A1]–[2TR D3] or [DEFINE] and one source from [STEREO A]/[STEREO B] (including LCR), for a maximum total of two sources. In V1.05 and later, turning on one key will turn off the other keys, allowing you to select a single monitor source more rapidly. If you want to select two sources simultaneously (as in V1.04 and earlier), press the corresponding panel keys simultaneously, or use the MONITOR screen. HA follows Recall Safe on/off operations (from V1.05) A new SAFE KEY MODE SELECT section has been added to the RECALL SAFE screen. If you turn on the HA+CH button, using the [RECALL SAFE] key of the panel or the RECALL SAFE button in the CH VIEW screen (INPUT VIEW function) to turn Recall Safe on/off will now also turn on/off the Recall Safe setting for the HA patched to the corresponding channel. If the CH button is on, the HA Recall Safe setting will not be linked. DCA group name Recall Safe and Selective Recall can be switched on/off (from V1.05) A new WITH NAME button has been added to the DCA area of the RECALL SAFE screen and SELECTIVE RECALL screen. This allows you to exclude just the DCA group name from DCA group Recall Safe and Selective Recall. If the WITH NAME button is on, Recall Safe and Selective Recall will apply to the DCA group names of DCA groups for which these functions are on. If the WITH NAME button is off, DCA group names are excluded from Recall Safe and Selective Recall. EN Displaying output channel names (from V1.20) Displaying output channel names (from V1.20) E screen that enables you to name output channels and view channel names on various screens. The procedure functions the same as the NAME screen for the INPUT PATCH function. However, the NAME screen is not included in the CH COPY, GLOBAL PASTE, or CSV IMPORT/EXPORT function. Parameter operation for Recall Safe/ Selective Recall (from V1.12) When using Recall Safe or Selective Recall, there has been a change in the behavior of parameters of which only one exists for each pair of adjacent odd-numbered/even-numbered channels or modules (see owner's manual p.165). If Recall Safe or Selective Recall is specified for only one of these channels or modules, the parameters will behave as follows. • PAIR Forcibly turned off (pairing will be defeated). • GATE STEREO LINK • COMP STEREO LINK • GEQ LINK LINK parameters will be forcibly turned off (link will be defeated). • DELAY GANG • ATT GANG GANG parameters will be recalled. If GANG turns On because of the recall, the relative differences of the DELAY and ATT parameter values following the recall will be maintained when they are edited. • MS DECODE • FIXED/VARI These will not be recalled. • PAN MODE The PAN MODE parameter will be recalled. However, if the recall would cause the PAN MODE setting to change from BALANCE to some other setting, or from some other setting to BALANCE, then the PAN MODE and PAN parameters will not be recalled. Also, if the recall causes the PAN MODE to become GANG PAN, the relative difference of the PAN parameter values following the recall will be maintained when they are edited. Support for the Y96K card (from V1.10) A PLUG-IN screen has been added to the EFFECT function. Also, PLUGIN parameters have been added to the RECALL SAFE screen and SELECTIVE RECALL screen of the SCENE function. These additions are in order to support the Y96K card that will become available in the near future from the Waves Corporation. For details on operation, refer to the owner’s manual for the Y96K. Please note that the Y96K card will operate as follows. • Data will be stored/recalled as scene data, but the Undo function is not supported. • If you power-off and then power-on the PM5D, conventional scene data will be in the same state as when you powered-off, but the Y96K will be in the state that was last stored or recalled. • If you recall a scene that produces a major change in the settings of the Y96K, the settings of the Y96K will change several seconds after recall occurs on the PM5D. If you want the timing of the change to be synchronized, use the FADE TIME screen to specify a START OFFSET. • Do not perform scene store/recall operations in the Y...

Otros modelos de este manual:
Instrumentos Musicales - PM5D-RH (130.17 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría