The power UID is located on the front of the disk enclosure.
4.
Remove all cabling from the rear of the enclosure. Ensure all cabling
is marked to facilitate re-cabling later.
WARNING!
A disk enclosure fully populated is heavy. Prior to
removing the enclosure from the rack, remove each
disk and label it with its bay number. Place each disk
on a clean surface. If this is not possible, two people
are required to remove the enclosure from the rack to
prevent injury.
5.
Remove hard drives from the enclosure.
Press the release button on the drive lever (1), and rotate the lever
to the left (2).
Then, pull and remove the disk drive out of the drive bays (3).
Verifying component failure
Check for improper or failed operation of the heartbeat and fault LEDs
on the front right bezel, and also the System UID LEDs. Improper LED
behavior may be an indication that the interconnect board needs to be
6.
Loosen the thumbscrews that secure the enclosure to the front of the
replaced. The following table describes LED behavior.
rack, and remove the enclosure from the rack.

7.
Remove the top access cover.
= Health. Solid green indicates the enclosure is operating
a.
Lift the access panel latch (1). The access panel will slightly
normally. Blinking green indicates that the enclosure is starting up
disengage from the enclosure.
and not ready, performing POST. Off indicates that there is no power.

b.
Slide the access panel to the rear (2) and lift away from the
= Fault warning. Flashing amber indicates a fault of lesser im-
chassis.
portance, while solid amber indicates a fault of greater importance.

= Unit identification. Push button to illuminate solid blue; push
again to turn off. The UID mimics the status of the UID at the front of
the enclosure. A remote session from the management utility can also
illuminate this LED.
Removing the power UID interconnect
board
1.
Schedule a maintenance window.
2.
Stop all I/O to the enclosure.
NOTE:
3.
Power down the enclosure by pressing and holding the On/Standby
button on the rear of disk enclosure, until the system power LED
A Torx tool with T-10 and T-15 ends is provided inside
changes from green to amber.
the enclosure chassis, on top of the I/O module
housing.
Page 2


...

Otros modelos de este manual:
datos de dispositivos de procesamiento - HP D2600 Disk Enclosure/S-Buy (329.66 kb)
datos de dispositivos de procesamiento - HP D2600 w/6 2TB 6G SAS 7.2K LFF DP MDL HDD 12TB Bundle (329.66 kb)
datos de dispositivos de procesamiento - HP D2600 w/6 3TB 6G SAS 7.2K LFF Dual port MDL HDD 18TB Bundle (329.66 kb)
datos de dispositivos de procesamiento - HP D2600 w/6 450GB 6G SAS 15K LFF Dual Port Enterprise HDD 2.7TB Bundle (329.66 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría