Be sure to match each air handler with its corresponding terminal strip connection. Use above diagram for each circuit. HCW18000/HCW24000 ! CAUTION ! • Connect one end of the ground wire to the outdoor unit ground terminal. • Use minimum 14 AWG wire conductors between the indoor and outdoor units. • Refer to page 16 to determine the wire size from the power ECR International Hyundai Ductless Split System14 ! CAUTION ! CONNECTING OF POWER SOURCE Before supplying the power, check that the voltage is within +6% of the rated voltage marked on the indoor unit label(s). supply to the condenser. ! CAUTION ! Make sure wire connections are secure otherwise electrical malfunction may occur. TEST RUN TEST RUN • After the test, set the lever to ON (I) position. The unit will stop the operation and hereafter the remote control will • Check the installation again. control the unit. • First, set the lever to OFF(O) position, then to ON(I) and TEST position slowly. (During the test, the indicator light will blink) 9/12 Btuh 18/24 Btuh CABLE CONNECTION 9/12 Btuh (Single or Multi-Zone) 1. Wiring between units should be cut to length. 2. Remove the wiring cover of the Indoor Unit(s) and the Outdoor Unit. 3. Insert the connection wire into the terminal block. ECR International Hyundai Ductless Split System15 CABLE CONNECTION 18/24 Btuh (Single Zone Only) ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE 4. Fix the connecting wire between units, with wiring fixture. 5. Attach the wiring cover. CABLE CONNECTION 18/24 Btuh (Single Zone Only) ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE 4. Fix the connecting wire between units, with wiring fixture. 5. Attach the wiring cover. Cooling Capacity SEER Heating Capacity (Btuh) (2) HSPF Volts/HZ/Phase Total Amps MCA Max. Fuse Nominal (1) Sensible HCW9000 9,500 7,030 10.9 --208/230/60/1 5.0 6.1 15 HCW12000 12,000 8,760 10.6 --208/230/60/1 6.2 7.6 15 HHW12000 12,000 8,760 10.4 12,500 7.2 208/230/60/1 6.2 7.6 15 HCW18000 20,000 14,200 10.7 --208/230/60/1 10.2 12.5 20 HHW18000 20,000 14,200 10.3 20,000 6.9 208/230/60/1 10.2 12.5 20 HCW24000 24,000 16,800 10.3 --208/230/60/1 12.1 14.8 25 HHW24000 24,000 16,800 10.0 24,000 6.8 208/230/60/1 12.0 14.8 25 (1) Indoor 80/67. F, Outdoor 95. F (2) Indoor 70/58. F, Outdoor 47. F Multi-Zone System Cooling Capacity (Btuh) SEER Heating Capacity (Btuh) (6) HSPF Volts/HZ/Phase Cond Fan Mtr Compressor Circuits 1 & 2 Indoor Fans Total Amps MCA HACR BRKR Min Volt Nominal (5) Sensible AMPS HP RLA LRA AMPS HP HMCW18000 (1) 18,000 12,600 10.9 --208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMHW18000 (2) 17,400 11,700 10.0 17,700 6.8 208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMCW24000 (3) 24,000 15,500 10.6 --208/230/60/1 0.72 0.2 5.85 29 0.22 0.06 12.9 13.4 20 197 HMHW24000 (4) 21,000 14,100 10.0 21,250 6.8 208/230/60/1 0.72 0.2 5.85 29 0.22 0.06 12.9 13.4 20 197 (1) HMCW18000 consists of two HACM09DB (9,000Btuh) air handlersand oneHCCM09DB condenser. (2) HMHW18000 consist...

Otros modelos de este manual:
Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría