If a leak is found, repair and recheck. After the indoor unit(s) have been installed, make sure that condensed water is properly drained. (If this is neglected, the unit(s) may become flooded.) Special care should be given to the following details: Leak Test Leak Check Drainage Indoor Unit Outdoor Unit (Heat Pump Only) • Drain hose must • Do not use a trap • Never put the • Do not tilt up- slope downward or kink. end of the drain ward. to the outdoor side. hose into the water. NOTE: Allow clearance for drainage of water or condensate. For outdoor condensation: • The outdoor unit has drain outlets on the base to drain condensation to the outside. • To drain condensation by hose (5/8” hose) with the drain socket, connect the socket to the center of the base and cover all other outlets with base caps. • Install the outdoor unit on a flat level surface and make sure condensation drains smoothly. • In cold areas, condensation and defrost water can freeze, therefore do not use the drain outlet caps during the cold season. • Electrical connection should only be made by a qualified professional. ECR International Hyundai Ductless Split System13 CONNECTING THE CABLE CONNECTING THE CABLE Use a dedicated circuit breaker for the air conditioner(s). • When connecting the indoor unit(s) to the outdoor unit please be sure to connect the same number on the indoor and outdoor unit terminal blocks. • Be sure to use approved connecting wire (14 gauge minimum). • When installing the air conditioner, please be sure to use the right power supply cable conforming to Canadian Electrical Code/National Electrical Code. NOTE: Interconnecting voltage is 208/230V. • The air conditioner always requires grounding. • Grounding must conform to local regulations. HYUNDAI ELECTRICAL INTER-CONNECT REVISION “B” PRODUCT Cool Model HCW9000/HCW12000/HMCW18000/HMCW24000 Cool and Heat Model HHW12000/HMHW18000/HMHW24000 HHW18000/HHW24000 NOTE: Gnd is Earth Ground HACW/HACM are cooling only indoor units HCCW/HCCM are cooling only outdoor units HAHW is heat pump indoor unit HCHW is heat pump outdoor unit NOTE: For Multi-zone systems, there are two sets of identical wiring terminals. Be sure to match each air handler with its corresponding terminal strip connection. Use above diagram for each circuit. HCW18000/HCW24000 ! CAUTION ! • Connect one end of the ground wire to the outdoor unit ground terminal. • Use minimum 14 AWG wire conductors between the indoor and outdoor units. • Refer to page 16 to determine the wire size from the power ECR International Hyundai Ductless Split System14 ! CAUTION ! CONNECTING OF POWER SOURCE Before supplying the power, check that the voltage is within +6% of the rated voltage marked on the indoor unit label(s). supply to the condenser. ! CAUTION ! Make sure wire connections are secure otherwise electrical malfunction may occur. TEST RUN TEST RUN • After the test, set the lever to ON (I) position. The unit will stop the operation and hereafter the remote contr...
Otros modelos de este manual:Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)