Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Danby, modelo HAHW12DB - HCHW12DB

Fabricar: Danby
Tamaño del archivo: 947.49 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


(See Fig. 1) 3. Make a 2 9/16” hole through the wall. Hole should be angled down to the exterior. (See Fig. 2) 4. Use a city grade wall pipe (outer diameter : 2 3/8”) as a Fig. 1 18/24 Btuh 9/12 Btuh 3.43”4.21” 1.18” 5.53” 9.12”10.83” 2’ 6” 2’ 2.25” 5.28” 6.89” 6.89” 5.79” 1.38” .85” 12.60” sleeve to protect the interconnection cable and the pip ing. (See Fig. 2) Fig. 2 Fig. 3 Wall pipe ( field supplied OD: 2 3/8”) Wall-Hook Plate Mounting Approximately 3/16”– 3/8” Indoor Outdoor Fig. 2 Pipe hole O 2.56” 1.93” Anchor plug holeAnchor plug hole 3’ 4” 18.74”5.04” 3’ 2” 10.33” 10.33” 15.63” 8.52” 8.52” 6.63”6.63” 1.81” 1.81”1.81” 1.81” 1.40” 3.93”2.92”4.31” 3.72” 3.93” 7.44”9.84” INSTALLATION OF THE INDOOR UNIT(S) ! CAUTION ! When inserting the pipes, protect the ends from dust or moisture by covering the flare connections with a cap or tape. (Take care not to twist or crimp pipes during installation.) For Right Rear Sided, Right Sided and Lower Sided Piping NOTE: Do not apply excessive force to these parts. 1. For right side and lower side piping, cut the indoor unit base(s) with a hacksaw and deburr the cut end with a file. (See Fig. 5) 2. Hang the indoor unit(s) on the upper portion of the installation plate while inserting the vinyl-taped pipes through the wall hole. Engage the lower projection with the claws of the installation plate. (See Fig. 7) NOTE: Make sure that the unit(s) are securely mounted, by slightly shaking the indoor unit(s). Fig. 5 Fig. 6 Fig. 7 Right rear sided (recommended) Right sided Lower sided Cut here Hacksaw Interconnection cable Indoor unit pipes Indoor unit drain hose Vinyl tape For Left rear Sided and Left Sided Piping: (See Fig. 8) Fig. 8 Left rear sided Left sided The length of the cable which will be passed through the wall hole should be longer than 40”. Fig. 9 Suction pipe Discharge pipe Dimensions from the center of the installa4” 6” tion plate for reference. 1. Regarding the left rear sided and left sided piping, the pipes must be connected indoors and must be adjusted to the actual installing length. Keep these pipes unrolled (See Fig. 9 and Fig. 10) 2. For left side piping, cut the indoor unit base(s) with a hacksaw and deburr with a file. Flare Coupling installation Band Tape after finishing leak test Discharge pipe Suction pipe Wall hole Fig. 10 Interconnection cable 3. Connect the indoor pipes and check for gas leaks. (See Fig. 10) After the leak test, wrap the flared joints with insulation and fix it with bands. 4. Remove the spacer from installation plate. Suction pipe Discharge pipe Indoor unit drain hose ECR International Hyundai Ductless Split System12 INSTALLING OF THE OUTDOOR UNIT Cut pipe by rotating the pipe cutter Pipe Turn the handle Clockwise while pushing it against the pipe Pipe cutter knife Yoke Do not damage the inside of the pipe. BarFlare nut Fix pipe turning clamp handle. Pipe INSTALLING OF THE OUTDOOR UNIT Cut pipe by rotating the pipe cutter Pipe Turn the handle Clockwise while pushing ...

Otros modelos de este manual:
Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría