Manual de usuario Friedrich, modelo HACW24DB - HCCW24DB

Fabricar: Friedrich
Tamaño del archivo: 947.49 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Fix the connecting wire between units, with wiring fixture. 5. Attach the wiring cover. Cooling Capacity SEER Heating Capacity (Btuh) (2) HSPF Volts/HZ/Phase Total Amps MCA Max. Fuse Nominal (1) Sensible HCW9000 9,500 7,030 10.9 --208/230/60/1 5.0 6.1 15 HCW12000 12,000 8,760 10.6 --208/230/60/1 6.2 7.6 15 HHW12000 12,000 8,760 10.4 12,500 7.2 208/230/60/1 6.2 7.6 15 HCW18000 20,000 14,200 10.7 --208/230/60/1 10.2 12.5 20 HHW18000 20,000 14,200 10.3 20,000 6.9 208/230/60/1 10.2 12.5 20 HCW24000 24,000 16,800 10.3 --208/230/60/1 12.1 14.8 25 HHW24000 24,000 16,800 10.0 24,000 6.8 208/230/60/1 12.0 14.8 25 (1) Indoor 80/67. F, Outdoor 95. F (2) Indoor 70/58. F, Outdoor 47. F Multi-Zone System Cooling Capacity (Btuh) SEER Heating Capacity (Btuh) (6) HSPF Volts/HZ/Phase Cond Fan Mtr Compressor Circuits 1 & 2 Indoor Fans Total Amps MCA HACR BRKR Min Volt Nominal (5) Sensible AMPS HP RLA LRA AMPS HP HMCW18000 (1) 18,000 12,600 10.9 --208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMHW18000 (2) 17,400 11,700 10.0 17,700 6.8 208/230/60/1 0.72 0.2 4.45 26 0.22 0.06 10.1 11.1 15 197 HMCW24000 (3) 24,000 15,500 10.6 --208/230/60/1 0.72 0.2 5.85 29 0.22 0.06 12.9 13.4 20 197 HMHW24000 (4) 21,000 14,100 10.0 21,250 6.8 208/230/60/1 0.72 0.2 5.85 29 0.22 0.06 12.9 13.4 20 197 (1) HMCW18000 consists of two HACM09DB (9,000Btuh) air handlersand oneHCCM09DB condenser. (2) HMHW18000 consists of two HAHM09DB (9,000Btuh) air handlersand oneHCHM09DB condenser. (3) HMCW24000 consists of two HACM12DB (12,000 Btuh) airhandlers and one HCCM12DBcondenser. (4) HMHW24000 consists of two HAHM12DB (12,000 Btuh) airhandlers and one HCHM12DBcondenser. (5) Indoor 80/67. F, Outdoor 95. F (6) Indoor 70/58. F, Outdoor 47. F ECR International Hyundai Ductless Split System16 COMPLETION OF INTERCONNECTING TUBING • Insert the wall cap into the wall, and fill the gap with sealant to prevent rain or wind. • When using the pipe cover, fill the gap in the wall through hole in the inside. OPERATING CHARACTERISTICS (Single Zone Cooling) OPERATING CHARACTERISTICS (Single Zone Cooling) 99 99 HCW9000 HCW12000 HHW12000 Outdoor Fan Speed Low High Room Temp. (°F) Outdoor Fan Speed Low High Room Temp. (°F) 85 85 Running Current (A) Low Pressure (PSI) Running Current (A) Low Pressure (PSI) Running Current (A) Low Pressure (PSI) Running Current (A) Low Pressure (PSI) 86 86 80 80 71 71 57 75 57 43 43 59 68 77 86 95 104 59 68 77 86 95 104 Outdoor Intake Temp. (°F) Outdoor Intake Temp. (°F) 5 6.5 Outdoor Fan Speed LowHigh Room Temp. (°F) Outdoor Fan Speed Low High Room Temp. (°F) 86 6.0 4.5 80 75 5.5 4 5.0 3.5 4.5 59 68 77 86 95 104 59 68 77 86 95 104 Outdoor Intake Temp. (°F) Outdoor Intake Temp. (°F) 99 99 HCW18000 HCW24000 Outdoor Fan Speed Low High Room Temp. (°F) Outdoor Fan Speed Low High Room Temp. (°F) HHW18000 HHW24000 85 71 57 86 85 80 75 71 80 75 57 43 43 59 68 77 86 95 104 59 68 77 86 95 104 Outdoor Intake Temp. (°F) Outdoor Intake Temp. (°F) 12 13 Outdoor Fan Speed LowHigh Room Tem...

Otros modelos de este manual:
Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM12DB - HCCM22DB (947.49 kb)
Los acondicionadores de aire - HACM09DB - HCCM99DB (947.49 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría