Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Yamaha, modelo CL5

Fabricar: Yamaha
Tamaño del archivo: 361.96 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


If you use a directory name containing any multi-byte character in your computer, store the firmware update files in a directory that consists only of ASCII characters (e.g. C:.temp). e sure to ensure compatibility of the update files with CL. If update files other than CL are applied, the device will become inoperable. In general, do not check the [Override Device Matching] option. If this option is left unchecked, only devices that support the file can be selected, ensuring that updating the device with invalid or wrong files is prevented. 5. Click [Next]. .“upgrade_tool.exe” may be blocked by the Windows Firewall. For Windows XP, click [Unblock] in such case. For Windows 7, select the [Private Network] checkbox and click [Allow access]. 6. Check the CL to update. Check the version of the update files and the version number indicated in the CL line. .If it is not indicated, click [Refresh]. It is still not indicated after that, the computer and the CL is not connected properly. Check that the cable does not come off or is not disconnected, TCP/IP is properly configured, and the CL is activated. 7. Click [Start]. The update operation will begin. “Updating(n/m)” appears in the Status field during updating. “Done” is displayed once update is completed. Update takes 2 to 4 minutes. During the update operation, do not turn off the power to the unit or disconnect the cable. If update fails due to disconnection of the power cable during the update, or due to other reasons, the device may become inoperative. .If update is not completed after 5 minutes, or update failure indication appears, click X at the upper right corner of Dante Firmware Update Manager to exit the program without turning the CL power off, and restart the procedure from the step 4. If update still fails, follow the instructions stated in “About Failsafe Mode” to perform the recovery processing. 8. Restart the CL series. The firmware update is now complete. ¦About Failsafe Mode Though software must be loaded from a flash memory drive during operations to use the Dante module integrated in the CL, data in a flash memory drive may be crashed as with the other storage devices. In many cases, such data crash is caused by turning the CL power off during firmware upgrading as with the other devices using flash memory drives. The Dante module have a specially protected flash drive section in order for recovery from such condition. When the main section is damaged, the program stored in the area is activated and the Dante module goes into the “failsafe mode.” To restore the Dante module in the failsafe mode, you need to send a recovery image from the Firmware Update Manager. To check if the Dante module is in the failsafe mode, use the Dante Controller. If the Dante module is in the failsafe mode, the respective device is displayed in red in the network grid view of the Dante Controller (version 3.1.x or higher). Further, a message “NETWORK AUDIO MODULE FAILED AND WAS RESTARTED.” appears also in the CL screen, so you may check that the DANTE version information is not displayed in the version field of the CL series unit. Described below are the procedures to recover the Dante module integrated in the CL series unit. 1. Turn off the power to the computer and the CL series. 2. Separate the CL from the Dante network. 3. Connect the Dante [PRIMARY] connector on the rear panel of the CL series unit to the Ethernet connector on the computer using an Ethernet cable. 4. Turn the computer power on and login to Windows with administrative privileges. 5. Turn on the power to the CL series. 6. Select [Start]>[All programs]>[Audinate]>[Dante Firmware Update Manager]>[Dante Firmware Update Manager ]. The Dante Firmware Update Manager will start up. .When running under Windows 7, the "User Account Control" dialog box may appear. Click [Continue] or [Yes]. 7. Click [Failsafe Recovery]. 8. Check the detected CL. 9. Click [Start]. The recovery operation will begin. 10. When the “Recovery image loaded” dialog box appears, click [OK]. 11. Exit the Dante Firmware Update Manager and then take the steps 2 through 6 described in “Updating the Dante firmware.” Click [Refresh] and check the version is displayed in several minutes. Please click [Refresh] again after waiting for a while, when not displayed. 12. When Version appears, click [Start]. The update operation will begin. “Updating(n/m)” appears in the Status field during updating. “Done” is displayed once update is completed. Update takes 2 to 4 minutes. During the update operation, do not turn off the power to the unit or disconnect the cable. If update fails due to disconnection of the power cable during the update, or due to other reasons, the device may become inoperative. .If update is not completed after 5 minutes, or update failure indication appears, click X at the upper right corner of Dante Firmware Update Manager to exit the program without turning the CL power off, and restart the procedure from the step 4. If...

Otros modelos de este manual:
Instrumentos Musicales - CL1 (361.96 kb)
Instrumentos Musicales - CL3 (361.96 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría