Descargado: 2   Tamaño del archivo: 273 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

REMOVE ALARM LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM. THE SLOT IS LOCATED DIRECTLY ABOVE THE ARROW. INSERT SCREWDRIVER E PUSH AWO WITH THE SCREWDRIVER STILL INSERTED, PUSH THE LOWER HALF OF THE ALARM AWAY FROM THE SCREWDRIVER, IN THE DIRECTION OF THE ARROW ON THE COVER LOCATE REMOVAL SLOT APPROX. 1cm INTO THE CENTRE OF THE REMOVAL SLOT INSERT A FLAT-BLADED SCREWDRIVER HORIZONTALLY TO REMOVSCREWDRIV& PUSH COVEER INTOSLR AY 2 B16009-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 2 Do not paint

Descargado: 0   Tamaño del archivo: 272 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

In the case of CO the premises should be by opening doors and windows. The user should call the gas supplier etc. In the case of fire, doors and windows should be closed to slow the spread of fire. The user should call the fire brigade etc. 5. TESTING 1. Regularly check that the green mains power light is on. The unit cannot detect CO if the mains power is off and the rechargeable battery back-up is depleted. (If it is off check circuit breakers, fuses, wiring etc). 2. Test the unit weekly by pr

Descargado: 1   Tamaño del archivo: 272 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

The wiring can be installed when appropriate. (Excessive dust and debris from building work can contaminate the sensor and cause problems, it will also invalidate the guarantee). If it must be installed, cover it completely, particularly around the edges, with a suitable covering, until all cleaning is finished. Figure 4 - Alarm Installation LOCATION FOR TAMPERPROOF SCREW (see page 16) PUSH SMALL SCREWDRIVER STRAIGHT IN TO RELEASE. PUSH COVER AWAY FROM SCREWDRIVER WARNING: DISCONNECT MAINS BEFOR

Descargado: 11   Tamaño del archivo: 168 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

8 B15583/R0/8/6/06 1:54 PM Page 9 NEVER IGNORE THE ALARM. Pre-Alarm: When the alarm detects over 50ppm CO the red 2 seconds. This helps locate CO leaks an indication straight away. (Without this feature the CO level would need to be at 50ppm 90 minutes for an indication to be given). Note the Pre-Alarm signal may be triggered by CO coming for example, from cooking with gas, from car engines or from nearby barbecues. This is usually not a concern, unless the Pre-Alarm signal persists until the al

Descargado: 0   Tamaño del archivo: 168 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

4. Screw the unit to the wall using the mounting holes. 5. Wire all the rest of the alarms similarly ensuring the terminals marked 1 are all connected together and that the terminals marked 2 are all connected together. 6. After installation press each test button (for at least 15 seconds) in turn and ensure each interconnected unit sounds within 10 seconds. The light (either green or red) will only flash rapidly on the unit with the test button pressed. These Carbon Monoxide Alarms should only

Descargado: 6   Tamaño del archivo: 168 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

The leaflet should be regarded as part of the product. If you are just installing the unit, the leaflet must be given to the householder. The leaflet is to be given to any subsequent user. INSTRUCTIONS B15583/R0/8/6/06 1:54 PM Page 2 Page CONTENTS 3 WHAT TO DO WHEN THE CO ALARM SOUNDS 4 CARBON MONOXIDE - THE SILENT KILLER! 5 WHERE TO PLACE CARBON MONOXIDE ALARMS 10 INSTALLATION 15 TESTING & MONITORING YOUR CO ALARM 19 MAINTAINANCE 21 LIMITATIONS OF CARBON MONOXIDE ALARMS 22 HOW TO PROTECT YOUR F

Descargado: 41   Tamaño del archivo: 168 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

IF IN DOUBT CONSULT A MEDICAL PRACTITIONER. 9. HOW TO PROTECT YOUR FAMILY Follow these guidelines to reduce the risk of Carbon Monoxide poisoning. (1) Know and look out for tell-tale signs that Carbon Monoxide may be present. These include: - The CO Alarm warning of abnormal levels. - Staining, sooting or discolouration on or around appliances. - A pilot light frequently going out. - A strange smell when an appliance is working. - A naked gas flame which is yellow or orange, instead of the norma

Descargado: 14   Tamaño del archivo: 82 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

All units are individually calibrated and tested in CO gas in order to ensure accuracy. In addition, the sensor module can be easily changed for a new module at the end of its 5 year life. The Ei206D also has a built-in digital display which shows the CO level sensed in parts-per-million (ppm). The Ei206D is housed in a slimline casing and can be easily secured to a wall or ceiling, with a separate base- plate and all necessary fixings supplied. As well as being easy to install and maintain, the

Descargado: 3   Tamaño del archivo: 243 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

6 B15584-R0-6/9/07 8:13 AM Page 7 Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described as “flu-like” symptoms). Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heart rate. Extreme Exposure: Unconsciousness, convulsions, cardiorespiratory failure, death. A high level of CO for a short period (e.g. 350 ppm CO for 30 minutes) will cause the same symptoms, a slight headache, as a lower level for a longer time (e.g. 150 ppm for 90 minutes). Table A shows

Descargado: 2   Tamaño del archivo: 99 kb   Fabricar: Ei Electronics  
Categoría: Detector de incendios
@name

Smoke Alarm Mode Ei 100R Ionisation High sensitivity - responds to all standard fires Dual Ionization chamber - quick response fast flaming fires Supply voltage 10.2 to 14 volts Interconnect up to 12 alarms Relay contacts Built in sounder Test button Kitemarked to BS5446-1:2000 5 year guarantee Product Description The Ei100R is an Ionisation Smoke Alarm that is designed to operate with suitable 12 volt control panels and to provide a loud local alarm. Ionisation smoke alarms operate on