@name

Accessori BEAMLRK, BEAMMMK, BEAMSMK Suitable for Beam Smoke Detectors Series 6500 Three-part reflector set increases the detection range to 100m Multi-mount kit with three-dimensional angle adaptation Surface-mount kit fig. A cM fig. B fig. C Reflector BEAMLRK 1 The Reflector BEAMLRK (fig. A) increases the maximum range of the Beam Smoke Detector Series 6500 to 100m. The package contains 3 parts. These three Material parts and the reflector included with the detector are put together, t

Descargado: 8   Tamaño del archivo: 181 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

Therefore, immediate response to a fire is imperative. The main objective of the fire detection control panel Series BC216 is to alarm and to react in time and, consequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca- The Fire Detection Control Panel BC216-1CE is a modularly designed compact control panel in 19“ slide-in technolog

Descargado: 44   Tamaño del archivo: 129 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

Therefore, immediate response to a fire is imperative. The main objective of fire detection control panel Series BC216 is to alarm and to react in time and, consequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca- The fire detection control panel BC216–1S is designed to be used in small systems with only one ADM loop. It comprises

Descargado: 6   Tamaño del archivo: 214 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

Individual detector identification can be achieved by means of an optional address module. • A slot for connecting the Detector Zone Extension MGE8-1 is available for the extension to 16 conventional detector lines. • Dry relay outputs indicate the alarm and fault conditions on the control panel. In addition, 16 open-collector outputs, two auxiliary inputs, and an additional relay output are available for general applications. • Up to 8 alarming devices can be operated as evacuation circuits dir

Descargado: 6   Tamaño del archivo: 215 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

Therefore, immediate response to a fire is imperative. The main objective of the fire detection control panel Series BC016 is to alarm and to react in time and, consequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca- Already in the basic version the fire detection control panel BC016-1 is equipped with eight detector lines in con

Descargado: 2   Tamaño del archivo: 97 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

With the dual design, the input side or the output side isolator - depending on the location of the short circuit - interrupts the connection to the faulty loop segment. Therefore the detector remains in operation. Specifications Current consumption max. 100|jA (quiescent) Ambient temperature -30°C to +70°C Relative humidity 0 - 93% (no condensation) Dimensions 0 x H 102 x 26 (mm) Colour cream Weight 70g Approval VdS G200100 Order number 246013 Order name Isolator Detector Base/Anal./

Descargado: 8   Tamaño del archivo: 92 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

Building Security. A mechanical theft protection of the detector can optionally be activated at the detector base. The Detector Base B501DG is 6mm higher than the Detector Base B501, and is therefore suitable for thick cables. It has the same height as the Isolator Detector Base B524IEFT-1. © I^BOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52H4-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED B501 DBL LST EN 0804.PDF • PAGE 1

Descargado: 1   Tamaño del archivo: 92 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

For special applications a range of accessories (for moist room, false cei- ling or flush installation) is available Specifications Ambient temperature -30°C to +70°C Relative humidity 0 - 95% (no condensation) Colour cream Detector Base B501 Dimensions 0 x H 102 x 20 (mm) Weight 53g Order number 246002 Order name Detector Base/Anal./500/200/SS B501 Detector Base B501DG Dimensions 0 x H 102 x 26 (mm) Weight 57g Order number 246015 Order name Detector Base/Anal./500/200/SS

Descargado: 0   Tamaño del archivo: 78 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

Due to its robust multi-wire screw terminals, the detectors can be wired with ease, thus achieving a secure and durable connection. The base provides the possibility to easily connect an external remote indicator, and has been designed for surface mounting in dry rooms. For special applications a range of accessories (for moist room, false ceiling or flush installation) is available. Specifications Ambient temperature -20°C to +70°C Relative humidity 10 - 93% (no condensation) Dimensions 0

Descargado: 0   Tamaño del archivo: 82 kb   Fabricar: LST  
Categoría: Detector de incendios
@name

Depending on the parameter setup in the fire detection control panel, the detector can operate either as maximum heat detector with an alarm temperature of 55°C, or as rate-of-rise heat detector with a maximum temperature of 55°C. The proven ADM loop technology with Apollo/Discovery Specifications Supply through loop voltage Current consumption max. 250|jA (quiescent) Ambient temperature -20°C to +70°C Relative humidity 0 - 95% (no condensation) Dimensions 0 x H 100 x 42 (mm) Colour white