To aid installation, the water coil connections may be moved to either side of the appliance. By removing the water coil and appropriate knockouts the water coil can then be re-inserted into the required orientation. This procedure should be carried out before mounting the appliance. Switch Panel Installation The backing box (standard double gang) should be rebated into a suitable wall. The box should be fitted so that the switch panel will be flush with the wall. Suitable conduit should be used

Descargado: 6   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

Thermostatic control A capillary type thermostat is factory fitted within the unit, as per ‘C’ in Fig. 7, giving a selection scale of 0-40.C. When the thermostat operates, the power output will reduce depending on the switch setting. -Fan only -No effect -Half Heat -Heater will reduce to Fan only -Full Heat -Heater will reduce to Half Heat To override the thermostat, first Isolate the supply to the heater. Remove the connection on terminal ‘1’ of the thermostat and reconnect it onto the piggy ba

Descargado: 98   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

L W H a L W H CAB 10 E/W/A 1065 320 262 CAB 15 E/W/A 1569 320 262 DAB 10 E/W/A 1057 391 361 DAB 15 E/W/A 1557 391 361 b 1 2 'x' A B CAB 10 920 160 CAB 15 1425 160 DAB 10 920 230 DAB 15 1425 230 A B 2.0m Min. 8 7 9 CAB ‘E’ & DAB ‘E’ CAB ‘A’ & DAB ‘A’ CAB ‘W’ & DAB ‘W’ Y X X Y CAB 10 840 240 CAB 15 1260 240 DAB 10 800 300 DAB 15 1300 300 Dimplex Compact Air Curtains Models : CAB10E, CAB15E, CAB10W, CAB15W, CAB10A, & CAB15A DAB10E, DAB15E, DAB10W, DAB15W, DAB10A, & DAB15A IMPORTANT: THESE INSTRUCTI

Descargado: 8   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

Fixing Positions This appliance may be either wall-mounted or fixed to a ceiling see Fig. 3a & 3b for fixing positions and ‘Mounting’ sections below for fixing details. A minimum distance of 100mm is required from the top of the appliance to ceiling - see ‘a’ in Fig. 1. The distance between the bottom of the appliance and the top of a door should be kept to a minimum - see ‘b’ in Fig. 1. This appliance should not be mounted less than 1.8m from the floor. Wall Mounting Using the wall mounting bra

Descargado: 11   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

This appliance should only be connected to the fixed wiring of the premises by means of conduit. This product should be mounted safely to solid wall or ceiling surfaces only. This product must not be subjected to water spray or immersion. Ensure the supply cables are of adequate current carrying capacity and are protected by a suitable fuse. If the appliance is mounted in a toilet or washroom, the appliance should be mounted such that no part of it can be touched by a person using a fixed bath o

Descargado: 6   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

In order to access the electrical connections, remove the outlet grilles (‘x’ and ‘y’ in Fig. 4) by releasing the quick release fasteners and hinging the mouldings as shown and then remove the bottom panel (‘z’ in Fig. 4). For the Water heated and Ambient models only, the pressure plate (‘w’ in Fig. 4) must also be removed. All Electric Models - Having removed a ‘knock out’ in the top panel, feed an appropriate supply cable (see ‘a’ in Fig. 6A) through a suitable cable gland (not supplied) fitte

Descargado: 4   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

Please refer to the table in Fig. 7 & 8 to make the appropriate connections to the PCB. Modular Connection Refer to instructions provided with the modular linking kit. Recessed Installation Refer to instructions provided with the recess installation kit. De-rating the unit to operate at 1/2 heat setting Please contact your sales or service agent using the contact details provided. Operation on a Single Phase Supply Please contact your sales or service agent using the contact details provided. Re

Descargado: 13   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

6B). All Models - A suitable cable (CAT5 or equivalent) for a switch panel (kit ref. - CABC5 for electrically heated models or CABC6 for water heated/ambient models) can be similarly introduced through the top panel and plugged into the circuit board as shown in Fig. 6A & 6B. If the unit is to be operated in conjunction with a door switch, a normally open switch should be wired as per Fig. 7 & 8 as appropriate. Note: If using a door switch, an additional 2 core (low Voltage) cable is required be

Descargado: 73   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

After Sales Service Your product is guaranteed for three years from the date of purchase. Within this period, we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions. Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee. Should you require after sales information or assistance with this product please go to where you will find our self hel

Descargado: 10   Tamaño del archivo: 694 kb   Fabricar: Dimplex  
Categoría: Los acondicionadores de aire
@name

2) An electrical 3-Port Solenoid Valve can also be connected into the system. Please contact your service agent using the contact details for more details. Door switch control (Water heated & Ambient models) By including a door switch in the circuit (as per ‘D’ in Fig. 8) the air curtain will respond to door openings as follows: (1) Door opening will energise the air curtain at the set conditions (switch box settings). (2) On door closure operation will continue at the set conditions for a furth