Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  
Descargado: 8   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado
@name

Spray Gun: Connects with spray wand to control water flow rate, direction, and pressure. Quick Connect Spray Wand: Allows the user to quickly change out high- pressure nozzles. See How To Use Spray Wand instructions in this section. Chemical Hose (not shown): Feeds cleaning agents into the pump to mix with the water. See How To Apply Chemicals/Cleaning Solvents instructions in this section. BASIC ELEMENTS OF AN ENGINE Refer to the engine manual for location and operation of engine controls. Chok

Descargado: 13   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado

1. Change pump oil after the first ten (10) hours of operation and every fifty (50) hours thereafter. When performing maintenance, you may be exposed to hot surfaces, water pressure, or moving parts that can cause serious injury or death! Before performing any maintenance or repair, disconnect spark plug wire, let engine cool and release all water pressure. The engine contains flammable fuel. DO NOT smoke or work near open flames while performing maintenance. To ensure efficient operation and lo

Descargado: 8   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado
@name

NOTE: Using a pump protector/ winterizer or *RV antifreeze is to provide proper lubrication to the internal seals of the pump regardless of temperature or environment. PRESSURE WASHER 1. Drain all water from high pressure hose. 2. Drain all water from spray gun and wand by holding spray gun in a vertical position with nozzle end pointing down and squeezing trigger. Store in gun holder. 3. Store chemical hose so it is protected from damage. 1. Obtain a funnel, six ounces of *RV antifreeze, and 16

Descargado: 6   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado

3. Verify the filter screen is in water inlet of pump. NOTE: Cone side faces out. 4. Connect water source to pump inlet. NOTE: Water source must provide a minimum of 5 gallons per minute at 20 PSI. 5. Connect high pressure hose to pump outlet. 6. If applying a chemical or cleaning solution, see How To Apply Chemicals/Cleaning Solvents instructions in this section. 7. Turn water source on. NOTE: Failure to do so could cause damage to the pump. 8. Start engine. See Engine Owners Manual for correct

Descargado: 10   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado
@name

Use PTFE liquid or tape. Pressure gauge inoperative or not registering accurately. Check pressure with new gauge and replace as needed. Relief valve stuck partially plugged or improperly adjusted. Clean and reset relief valve to system pressure and correct bypass. Check supply tank for contamination. Worn seat or valves. Clean or replace with valve kit. Inlet suction strainer clogged or improperly sized. Use adequate size for inlet pump connection and fluid being pumped. Clean frequently. Worn s

Descargado: 14   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado
@name

7. Remove five colored quick connect nozzles from plastic bag and insert them into correct grommet on the nozzle holder. NOTE: Nozzles are color coded to match colored nozzles on panel. 8. Slide the formed rubber covers onto the handle's on-board hose and wand storage. 9. Add engine oil (supplied) to engine. Refer to Engine Owners Manual supplied by engine manufacturer for correct procedure. NOTE: There will be a slight amount of oil in the engine from factory testing. NOTE: The high pressure pu

Descargado: 4   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado

NOTE: The frame is equipped with an oil drain hole to help make changing the engine oil easier. PUMP NOTE: The pump was filled with oil at the factory. 1. Change pump oil after the first ten (10) hours of operation and every fifty (50) hours thereafter. To Check Oil: 1. Remove dipstick/oil plug from pump and wipe clean. 2. Insert dipstick/oil plug fully into pump, then remove it. Dipstick/oil plugOil Drain Plug 3. Oil level is correct when oil covers the lower 1/2 inch of end of dipstick/oil plu

Descargado: 5   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado
@name

If a pump protector/ winterizer is not available, *RV antifreeze needs to be run through the pump as outlined in the steps below. NOTE: Using a pump protector/ winterizer or *RV antifreeze is to provide proper lubrication to the internal seals of the pump regardless of temperature or environment. PRESSURE WASHER 1. Drain all water from high pressure hose, coil it, and store it in cradle of the pressure washer handle. 2. Drain all water from spray gun and wand by holding spray gun in a vertical p

Descargado: 7   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado

When there is a steady stream of water present, turn water source off. Reconnect water source to pump inlet and turn on water source. Squeeze trigger to remove remaining air. 8. Move choke to the "No Choke" position. 9. Move throttle control lever to the "Fast" position. 10. Use high pressure hose under 100 feet. Will not draw chemicals 7. Chemical build up in chemical injector. 1. Wand not in low pressure. 2. Chemical filter clogged. 3. Chemical screen not in chemical 4. Chemical adjustment kno

Descargado: 10   Tamaño del archivo: 2 mb   Fabricar: Graco Inc.  
Categoría: Equipo de lavado
@name

2. Reduce the speed of the gasoline engine (RPM). Slow the engine down and the water pressure will go down with it. Step 3 is for models PCH2627, PCH3030 and PCH3540HR. 3. Adjust the pressure regulator on the pump. Turn the pressure regulator knob counterclockwise to lower pressure. Refer to the illustrations to identify your pressure regulator. Once you have finished using your pressure washer, return the pressure regulator to its original position by turning it clockwise. DO NOT attempt to inc