Net. Wt. (Lbs.) Model Approx. Net. Wt. (Lbs.) Volts Phase kW No. Elements No. Mtg. Holes 9/32” Dia. No. Circuits Dimensions (In.) A B C D E H K L M ADH-005 ADH-010 ADH-015 8 15 25 ADHT-005 ADHT-010 ADHT-015 10 20 30 480 480 480 3 3 3 5 10 15 3 6 9 10 10 12 1 1 1 5-5/8 7-5/8 9-5/8 20-3/8 20-3/8 20-3/8 28-1/8 28-1/8 28-1/8 4 6 8 1/4 1/4 1/4 2-1/2 3-1/2 3 3-1/2 3-1/2 3-1/2 11-1/8 11-1/8 11-1/8 9-1/2 9-1/2 9-1/2 ADH-020 ADH-025 ADH-030 35 40 55 ADHT-020 ADHT-025 ADHT-030 40 50 65 480 480 480 3 3 3 2
Finstrips No. Ckts. Dimensions (In.) (Note 1) (Note 2) A B C CAB-62 CABB-62 CAB-611 CABB-611 25 120, 208, 240 or 480 1 or 3 6 6 1 10-3/4 15-7/8 11-1/2 CAB-122 CABB-122 CAB-1211 CABB-1211 35 208, 240 or 480 1 or 3 12 9 1 15-3/8 18-1/2 14-1/8 CAB-152 CABB-152 CAB-1511 CABB-1511 40 208, 240 or 480 1 or 3 15 9 1 15-3/8 21-5/8 17-1/4 CAB-202 CABB-202 CAB-2011 CABB-2011 55 208 or 240 3 20 12 1 20-1/8 21-5/8 17-1/4480 1 or 3 CAB-252 CABB-252 CAB-2511 CABB-2511 65 208 or 240 3 25 12 1 20-1/8 26-1/8 21-3
(Supersedes PF423-1)PF493-1CAF-12 CCAS-12161-506171-001JULY, 20024andInstallation,OperationMAINTENANCE(Supersedes PF493) Architectural Convection Heaters Type CAF-12 and CCAS-12 CAF-12 CCAS-12 TABLE 1 — Specifications Model Model Volts Phase Watts Amps BTUH Dimensions (In.) Weight (Lbs.)Height Length Depth CAF-12F211 CCAS-12F211 208 1 1125 5.4 3,838 12 24.3 5.75 19 CAF-12F211 CCAS-12F211 208 3 1125 3.1 3,838 12 24.3 5.75 19 CAF-12F211 CCAS-12F211 240 1 1125 4.7 3,838 12 24.3 5.75 19 CAF-12F211 C
CAF-20 Series Architectural Cabinet Convection Heater TABLE 1 — Specifications Length1-1/22Back ViewBottom View(Front Inlet Version Shown) 2-3/4Terminal BoxTerminal Box20115-3/4Side View(Less End Cap) Figure1 Model Volts Phase Watts Amps BTUH Length Weight (Lbs.) CAF-20215 208 1 1,500 7.2 5,118 24.3 32 CAF-20215 208 3 1,500 4.2 5,118 24.3 32 CAF-20215 240 1 1,500 6.3 5,118 24.3 32 CAF-20215 240 3 1,500 3.6 5,118 24.3 32 CAF-20215 277 1 1,500 5.4 5,118 24.3 32 CAF-20215 480 1 1,500 3.1 5,118 24.3
MODEL NUMBER DESCRIPTION TABLE 2 CAF-20 2 20 21 01 A9 Code Control Options (Factory Installed) A9 = Built-in DP tamperproof hydraulic thermostat 208 - 480V A3 = Built-in 3P tamperproof hydraulic thermostat for 3P voltages 208 - 480V A4 = Built-in 24V low voltage relay for 1P voltages 208 - 480V A5 = Built-in 24V low voltage relay and transformer for 1P voltages 208 - 480V A6 = Built-in 24V contactor for 3P voltages 208 - 480V A7 = Built-in 24V contactor and transformer for 3P voltages 208 - 480V
5. Proceed to the wiring instructions. Recessed Wall Note: The use of a ALTB Trim kit is strongly recommended when recessing the heater. A recess opening dimension of 20-1/2” high and the length of the heater is required to install this heater. The heater may be recessed up to a depth of 5-5/8”. Top PanelScrews BottomPanelScrewsFigure 2 Figure3 INSTALLATION (Recessed Wall) 1. Unpack the heater from the carton and remove the front panel. Note: The front panel screws are recessed at the bottom of
WARNING: Hazard of Fire. Keep electrical cords, drapes, rugs and other furnishings away from the heater. The normal operating temperatures of cabinet convectors are relatively high. Proper operation requires free circulation of room air through the heating element. Installation Wall 1. Unpack the heater from the carton and remove the front panel. Note: The front panel screws are recessed at the bottom of the top front panel at each end of the heater. (Figure 2) Remove top front panel by pulling
4. Mount the back plate to the wall using suitable fasteners (provided by customer) using the scribed line on the wall to keep the heater level. TIP: Should the wall surface be uneven, secure the heater back panel to the high spots. This will avoid a distorted appearance. 5. Proceed to the wiring instructions. Recessed Wall Note: The use of a ALTB Trim kit is strongly recommended when recessing the heater. A recess opening dimension of 20-1/2” high and the length of the heater is required to ins
4. Secure the trim frame using the #8 screws provided with the trim kit. TIP: The bottom trim may be omitted if the heater is to be installed at floor level. 5. Prepare the wall recess opening to accept the heater. TIP: Leave approximately 1/2” clearance to insert the heater cabinet. 6. Secure the back plate into the recess opening using suitable fasteners (Provided by customer). 7. Proceed to the wiring instructions. WIRING Note: All wiring should be done in accordance with local codes and the
MODEL NUMBER DESCRIPTION TABLE 2 CAF-20 2 20 21 01 A9 Code Control Options (Factory Installed) A9 = Built-in DP tamperproof hydraulic thermostat 208 - 480V A3 = Built-in 3P tamperproof hydraulic thermostat for 3P voltages 208 - 480V A4 = Built-in 24V low voltage relay for 1P voltages 208 - 480V A5 = Built-in 24V low voltage relay and transformer for 1P voltages 208 - 480V A6 = Built-in 24V contactor for 3P voltages 208 - 480V A7 = Built-in 24V contactor and transformer for 3P voltages 208 - 480V