Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario HP, modelo HP NetServer LC 3

Fabricar: HP
Tamaño del archivo: 38.24 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


HP NetServer LXr 8500 Technical Reference Label
A I/O Baseboard
B Processor Baseboard
Left Processor Carrier Board
C Boot Order
Connectors to
CMOS Battery
Connector to
and Carrier Boards
Grand Connector
Boot Order
6.
PCI Slot 3
Midplane Board
(under I/O Baseboard Shield)
Midplane Board
1. Primary IDE CD-ROM
7.
PCI Slot 4
2. Flexible Disk
8.
PCI Slot 5
Number of
Processors in
Terminators
Processor
3. PCI Slot 1
9.
PCI Slot 6
PCI Slot Dividers (10)
Processors
Slots Listed
Baseboard
4. PCI Slot 2
10. PCI Slot 7
(Add to Slot)
L=Left R=Right
5. Embedded SCSI
11. PCI Slot 8
SCSI A
1 (L1)
L1
L2
Processor Carrier
SCSI A
12. PCI Slot 9
IDE
L3
Board Connector
SCSI B
13. PCI Slot 10
D7054-80206, Rev B
(for Right)
I/O Configuration Switches
L4
2 (L2)
L1
L3
Locking Bar
L2
L4
Release
Right Processor
SCSI B
L1
L2
L3
L4
Processor Cage
Carrier Board
P10
P9
P8
P7
P6
P5
P4
P3
P2
P1
Flexible Disk
3 (L3)
L1
L4
Locking Bar
L2
for Processor 5
I C
2
Connectors
L3
Unused
4 (L4)
L1
None
Front Panel
for Processor 6
PCI LED Board Connector
L2
Board Connector
15
Cache Coherency
L3
12
Top Tools RCC
J6A1 Jumper Block
Filter Connectors
for Processor 7
L4
on Processor
16
Basebord
I/O Riser Board
5 (R1)
L1
R1
R2
for Processor 8
L2
R3
R1
R2
R3
R4
L3
R4
Front of Board
Processor Carrier Board
L4
Connector (backside)
6 (R2)
L1
R1
R3
Jumper Block J6A1
L2
R2
R4
Caution:
+3.3 VDC
+3.3 VDC
+5 VDC
+5 VDC
L3
1
2
1
2
1
2
1
2
es, all covers and panels
In a multiple processor configuration, the processors all must be the
33/66 MHz
33/66 MHz
33 MHz
33 MHz
L4
I/O Configuration Switches
3
4
3
4
3
4
3
4
same HP product number, the same frequency, and the same cache size.
Bus 3
Bus 2
Bus 1
Bus 0
OPEN = OFF CLOSED = ON
7 (R3)
L1
R1
R4
5
6
5
6
5
6
5
6
Processors 1 - 4 should be mounted on the left Processor Carrier Board.
Note:
L2
R2
OPEN
Processors 5 - 8 should be added to the Right Processor Carrier Board.
If 66 MHz is selected (Setup Utility), but a
L3
R3
7
8
7
8
7
8
7
8
12345
See the table in this panel.
Reserved
33 MHz card is present at boot time, the
L4
Recovery Boot
9
10
9
10
9
10
9
10
bus runs at 33 MHz.
Operating a CPU chip at a lower or higher speed, or at an incorrect
OPEN
Reserved
8 (R4)
L1
R1
None
11
12
11
12
11
12
11
12
voltage, may result in unreliable operation -- or cause catastrophic or
Buses can be dynamically allocated, which
Reserved
hidden damage to the chip.
changes the defaults shown.
L2
R2
CMOS Clear
13
14
13
14
13
14
13
14
67
Password Clear
L3
R3
All I/0 Slots are PCI Hot-Plug, 32 or 64 bit.
Repairs due to unauthorized jumper settings or use of incorrect processor
Shaded rectangle
PCI Hot-Plug Switch Disable
L4
R4
15
16
15
16
15
16
15
16
combinations are not covered under the warranty. Processors supplied
represents the depressed
8
All accept the Universal Card (which can
and warranted by HP for NetServers have an HP label.
side of the rocker switch
Reserved
accept a 3.3 VDC or 5 VDC signal).
400MHz
450MHz
500MHz
550MHz
Audience Assumptions
D Memory
Memory Board Latches
This Service Reference Label is for trained service
personnel. Hewlett-Packard Company assumes you
E Power Supply Modules
Memory DIMMs:
are qualified in the servicing of computer equipment
Power Supply LEDs:
DIMM Installation Guidelines
Slot J16
and trained in recognizing hazards in products with
• For up to eight DIMMs, use one memory board in
Slot J15
hazardous energy levels.
Caution:
Electrostatic Discharge To avoid catastrophic or
PWR
AC Input Indicator
either slot, left or right. (No terminator is required
Slot J14
If you remove a power supply, wait at least
in the empty slot.) With one memory board, you
Slot J13
hidden damage to components, wear a wrist strap
Green = AC power input to module OK.
15 seconds to reset before reinserting it.
can load DIMMs in any sequence, any slot, any size.
and use a static-dissipative work surface connected
Slot J12
Blinking Green = AC power input to system OK.
to the chassis when handling components. Use an
Slot J11
System in standby mode.
• For more than eight DIMMs, a second memory
antistatic service kit, such as 3M
® 8501/8502/8505
Push here
Slot J10
Off = No AC power.
board must be installed to prevent RFI and to
or equivalent.
to start
Slot J9
Even at low room temperatur
maintain compliance with Electromagnetic
Predictive Fail
PRFL
latches
Slot J8
must be in place to provide controlled airflow for
Compatibility Standards.
Blinking Yellow = Power supply fan is slow.
system reliability.
Slot J7
Power supply may fail.
• If you are using two memory boards, you can leave
This information is subject to change without notice
Slot J6
and is provided without warranty.
Power Supply Configuration
one empty and install up to 16 DIMMs on the other
Off = Fan speed normal.
Slot J5
©1999, Hewlett-Packard Company. All rights reserved.
memory board.
• AC Input to power supply is 200V - 240V
Slot J4
FAIL
Attention Indicator
• If you install DIMMs on both memory boards,
• Two power supplies (minimum) are required
Slot J3
Off = Normal operation.
configure both identically. If DIMMs of different
Slot J2
• Power supplies can be installed in any power
Yellow = Power supply failure.
CAUTION!
sizes are present in the same-numbered sockets
Slot J1
supply bay
Blinking Yellow = Current limit exceeded.
on both boards, a mismatch will be detected and
Do not remove top cover while unit
• A power supply must be installed in each bay
Possible short in power supply or server.
mismatched DIMMs reconfigured to the lower value
is on. (PCI access panel can be
at all times to ensure proper system cooling
(or unpaired DIMMs will be ignored).
removed.)
D7054-80206, Rev B
F Control Panel
G Rear Panel and Cabling
Dual-Bus
Power Button
Secure Mode Button
Scroll Down One Line
HP NetServer LXr 8500 (rear)
Configured Storage
Power LED
Secure Mode LED
Scroll Up One Line
"Traffic Light" LEDs:
Red
Reset
Yellow
Green
D7054-80208, Rev A
AC In
Reset Button
Enter
Escape
Not Used
Two Line Display
Control Buttons and LEDs
Display works even when the server has
Control
Description
powered down or hung, as long as the server
has standby power.
Power Button
Turns system power on and off.
External SCSI Port
Single-Bus
Power LED
Steady green when power is on; flashing green when
system is in ACPI Sleep; off when system power is
Keyboard *
Configured Storage
"Traffic Light" LEDs
off.
Red
Yellow
Green
Reset
Performs a system hard reset.
Mouse *
Off
Off
Off
Main Power is off. System may
Secure Mode
Puts the system in Secure Mode, if the system
Serial B
or may not have standby power.
Button
was configured for Secure Mode.
Serial A
Flashing
Off
Off
A system component has failed. If the
I/O Riser
DAC
SCSI
Secure Mode
Glows steady green when the system is in Secure Mode.
component was redundant (i.e., a power supply
Board
Board
Connector
LED
VGA
or fan), the system may still be operating.
Escape
Return to previous menu.
Off
Flashing
Off
A condition exists which may cause the
failure of a system component.
Parallel
Enter
Select an item from the menu.
Port
Down Arrow
Scrolls the display down one line or up one line.
Off
Off
On
The system is operating normally.
* Keyboard and Mouse ports
and Up Arrow
are interchangeable
D7054-80208, Rev A


...

Otros modelos de este manual:
Computadoras - HP NetServer LC 2000 (38.24 kb)
Computadoras - HP NetServer LC 2000r (38.24 kb)
Computadoras - HP NetServer LC II (38.24 kb)
Computadoras - HP NetServer LC Plus (38.24 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría