Otros manuales para este modelo:
Resumen del manual
System Board
Terminator
Fan Connector
System Switches
*
System Switches
Backplane
Resource Sharing
Secondary Voltage
CPU Frequency (by MHz)
HP recommends for most environments to let the
Secondary
Regulator Module
Battery
server assign resources and PCI interrupts. The LC 3
Processor
Socket
100 MHz FSB
To Control Panel
To System Board
is capable of avoiding interrupt conflicts through
300
350
400
450
500
550
interrupt sharing.
Standby Power LED
CPU
However, when two similar or dissimilar PCI Cards
Serial B
Speed
To Management
continue to have conflicts, it is possible to manually
Remote
Port
Access
*
assign interrupts through the BIOS Setup Utility.
Serial A
DIMM LEDs
0 1 2 3
PCI 6: LAN Adapter
The following slots share interrupts:
FSB (CPU Bus Speed)
SCSI
PCI 5
A I C
Parallel
7880
PCI 4
Interrupt A: Slot 2 and Slot 6
Primary Processor
I/O
ON
ON
ON
ON
ON
ON
D6123-80202, Rev D
OFF
OFF
OFF
OFF
OFF
OFF
PCI 3
Primary Voltage
PCI 2
Interrupt B: Slot 3 and SCSI-A
Mouse
Regulator Module
Test Only (7 & 8)
PCI 1 / ISA
(integrated controller)
DIMM Memory Sockets
0
Keyboard
Password (6)
Interrupt C: Slot 1 and Slot 4
Boot Order
1
SCSI
Monitor
Clear Password
1. IDE CD-ROM
2
Cirrus
IDE CD-ROM
2. Floppy Drive
Logic
Config. Memory (5)
Flexible Disk
3. Embedded SCSI
3
Clear Config. (CMOS)
* Requires External Modem
for Remote Access
Slot 5 does not share any interrupts
4. PCI 6
5. PCI 5
6. PCI 4
VRAM
VRAM Upgrade
7. PCI 3
HP NetServer LC 3
8. PCI 2
Remove Terminator to
BIOS Flash
9. PCI 1
*
Hot-Swap Model
EEPROM
Technical Reference Card
install Secondary Processor
Electronic Support Services
System Board
Management Port
Backplane
• Internet Web Page http://www.hp.com/go/netserver
DIMM Installation Rules
SCSI
Cabling Key
• Internet FTP ftp://ftp.netserver.hp.com
• Use only 100 MHz SDRAM DIMMs. Do not use
• DIMMs can be 64MB, 128MB, or 256MB in
To SCSI Adapter
• CompuServe Library GO HPPC
EDO Memory Modules from earlier LC models,
any combination
Available Connector
Card or Embedded
IDE
• HP Navigator CD
which may fit but will not function correctly
CD-ROM
• DIMMs can be installed in any order in any
Engaged Connector
Control
SCSI
Panel
Flexible
Support Questions
• Use only HP DIMMs listed on this label at far right
of the four DIMM sockets
C42 68-pin SCSI Cable
Disk
• HP-Authorized Reseller
(5183-2412)
Fan Cable
• CompuServe Discussion Forum GO HPPC
Standard Model
C3 External SCSI Cable
Backplane
• US / Canada Phone Support 1-970-635-1000
(5182-6749)
FC
Backplane
• Europe Phone Support (+31-20) 581-3330 (Netherlands)
SCSI
D6 IDE CD-ROM Cable
D6
Example of
System Board
(5183-2411)
Flexible
External SCSI
HP has offices in over 100 countries.
Disk
Connector
Flexible Disk
Shelf 1
NetRAID
Check your local telephone directory.
Control Panel
IDE CD-ROM
FC Flexible Disk Cable
C3
C52
(5183-2410)
Configuration
CD-ROM
Available HP Accessories
68-pin SCSI Cable
CD-ROM
Shelf 2
For a complete list of tested accessories, download Order
C52 (5183-2484)
Shelf 3
Flexible
Power
**
Assistant from the HP Web page.
Disk
2
Supply
Shelf 3
I 2C I C Cable
(5182-6730)
Audience Assumptions
OUT
IN
C42
2
This Service Reference Label is for trained service
Management
End of
I C
Port
FC
C82 68-pin SCSI Cable
personnel. Hewlett-Packard Company assumes you are
Cable C52
(5183-3488)
sw
qualified in the servicing of computer equipment and
Fan Cable
Flexible
Built-in SCSI
Hot-Swap
C52
trained in recognizing hazards in products with hazardous
Disk
Shelf 1
D6
Terminator
Drives
energy levels.
Backplane
1 0 3
Flexible
68-pin to 50-pin Adapter
* *
Electrostatic Discharge
Disk
(for tape backup only)
CD-ROM
Shelf 2
Alternate Switch
Default Switch
1
To avoid catastrophic or hidden damage to components,
(5183-2427)
Settings (1, 2, 3)
Settings (1, 0, 3)
Rear View
C82
wear a wrist strap and use a static-dissipative work surface
CD-ROM
OFF ON
OFF ON
Shelf 3
connected to the chassis when handling components. Use
Power Supply
1
1
an antistatic service kit, such as 3M
® 8501/8502/8505 or
Shelf 3
2
2
equivalent.
Shelf 4
Shelf 4
3
3
Even at low room temperatures, all covers and panels
4
4
Shelf 5
must be in place to provide controlled airflow for system
Shelf 5
5
5
C52
reliability.
Shelf 6
6
6
Shelf 6
1 Order D5968A
This information is subject to change without notice
If Shelf 3 has
SCSI ID 2
2
and is provided without warranty.
SCSI ID set to 0
reserved for DAT
**
NetRAID 1
2 Order D4992A
©1999, Hewlett-Packard Company. All rights reserved.
P/N: D6123-80202, Rev D