(44) 01308 423441 AFS1237 Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Sherborne, range to ensure ultimate performance and years of trouble free enjoyment. Every detail on the stoves has been carefully engineered and designed which is why we are so confident in the reliability of our product that we offer a Lifetime Guarantee. Should you have any questions about our Sherborne range of stoves that are not covered in this
AFGS1095 CONTENTS INSTALLATION Safety Notices General Information Contents List & Part Identification Important Notices Statutory Requirements Certification Technical Data Gas Fire Dimensions Installing The Stove Preparation of the stove Stove Location Shelf Clearances Flue System Fitting The Flue Spigot And Blanking Plate Rear / Top Flue Options Connecting The Gas Supply Pressure Test Sequence Fitting & Arranging The Coals Fitting & Arranging The Logs NG Fitting & Arranging The Logs LPG Install
An ENVIROFIRE dealer will be happy to assist you in obtaining information with regards to your local building codes and installation restrictions. The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure, it is very important to ensure that the exhaust system be sealed and airtight. This unit is designed to burn pelletized wood fuel only. Do not use any other type of fuel, this will void any warranties stated in this manual. THE USE OF C
This is due to back-pressure in the exhaust, caused by the air flow around the house. Text Box: 5.0” Text Box: 10.812” Text Box: 11.938” Text Box: 16.625” Text Box: 1” Text Box: THROUGH WALL INSTALLATION FREESTANDING INSIDE VERTICAL INSTALLATION 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. 2. Place a non-combustible hearth pad where necessary. 3. Place the unit on the hearth pad and space it in a manner so when the pellet vent is insta
Screw rod in place. - Re-install steel brick liner and screw in place. - Replace top baffle EXHAUST VENT Soot and Flyash: Formation and Need for Removal: - The products of combustion will contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting s
Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. 2. Remove the knob and outer nut from the knob. Push the rod through the hole in the slider. Place the lock nut on the rod and tighten, leaving a 1/32’ gap between the slider and one of the nuts. 3. Make sure the slider moves freely. Close the side panel and tighten screws after placing the rod through the panel. Screw the knob onto the slider. OPERATION - On the low heat output
12. 120°F (49°C)-N/C TEMPERATURE SENSOR (IGNITER SHUT DOWN SENSOR) This sensor (mounted on the exhaust channel) will turn the igniter off when the exhaust channel temperature reaches 120°F (49°C). 13. IGNITER Is a heating element used to ignite the fuel? When the start up switch is activated, the igniter is has power going to the igniter when the switch is in the manual position. Air passes through the igniter tube, which becomes super heated drying the fuel and then igniting the fuel through co
February2005 3 Parts Diagram - Steel .............................................................................................................................. .................................................... February2005 3 Warranty Sherwood Industries Ltd. gives a five year limited warranty on all steel manufactured parts. A one-year warranty is provided on all electrical components. The above limited warranties are extended only to the original purchaser. There is no warranty on the fo
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE EF THERMO 28 OWNER’S MANUAL ........ PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. Contact your building or fire officials about restrictions and installation inspection requirements in your area. 50-877 Table of Contents Introduction.....................................................
• Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. ............................ WARNING If the information in these instruc- tions is not followed exactly, afire may result causing propertydamage, personal injury, or death. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity ofthis or any other appliance. • Do not overfire - If heater or chimney connector glows, y