DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. POWER ON This symbol indicates the principal on/off switch is in the on position. POWER OFF This symbol indicates the principal on/off switch is in the off position. PROTECTIVE GROUNDING TERMINAL This symbol indicates a terminal which must be connected to earth ground prio
• Test AC outlets at the computer and monitor for proper polarity and grounding. • Use only with grounded outlets at both the computer and monitor. When using a backup power supply (UPS), power the computer, the monitor and the AutoView 424 unit off the supply. NOTE: The AC inlet is the main disconnect. Rack mount safety considerations • Elevated Ambient Temperature: If installed in a closed rack assembly, the operation temperature of the rack environment may be greater than room ambient. Use ca
5 Recommended configuration......................................................................................................5 Cable/network specifications...................................................................................................... 6 Remote Power Control option....................................................................................................6 Installing the Digital Desktop System......................................................................
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation o
AutoView is a trademark of Cybex Computer Products Corporation. All other marks are trademarks or registered trademarks of their respective owners. Cybex Computer Products Corporation is a wholly owned subsidiary of Avocent Corporation. © 2001 Avocent Corporation. All rights reserved. FCC Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has
Follow the lettered and numbered instructions below to successfully install your DSR unit. The figure below illustrates one possible configuration. Figure 2.2: Basic DSR Configuration WARNING: To reduce the risk of electric shock or damage to your equipment- - Do not disable the power cord grounding plug. The grounding plug is an important safety feature. - Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times. - Disconnect the power from the unit by unplugg
Enable the screen saver. Names Identify servers by unique names. Changing the display behavior Use the Menu dialog box to change the display order of servers, set a time to delay display of the OSCAR GUI after pressing Print Screen and change the switch connection mode. Figure 3.3: Menu Dialog Box To access the Menu dialog box: 1. Press Print Screen to launch OSCAR. The Main dialog box appears. 2. Click Setup-Menu in the Main dialog box. The Setup menu appears. To choose the display order of ser
The DSRIQ-SRL (serial) module is a DCE device that provides the primary interface between a serial device and a DSR appliance. It provides VT100 terminal emulation, break suppression and port history in a convenient module. The DSRIQ-SRL is compatible with the ARI port of a DSR system. These DSRIQ modules eliminate the need for extra rack space or additional cables. The connection between the DSR system and DSRIQ modules is via industry standard UTP cabling. DSR Installer/User Guide DSR Installe
NOTE: Scanning will begin as soon as the scan button is checked. To cancel scan mode: 1. Select a server if OSCAR is open. -or- Move the mouse or press any key on the keyboard if OSCAR is not open. Scanning will stop at the currently selected server. -or- If OSCAR is not open, press Print Screen. The Main dialog box will appear. 2. Click Commands. The Commands dialog box appears. 3. Clear Scan Enable. Setting Console Security Use the Security dialog box to set security on your local port console
The maximum length should not exceed 10 meters (32.8 feet). WARNING: Always disconnect power before changing any wiring. To reduce the risk of electric shock or damage to the equipment, this product must be installed in accordance with the following guidelines. This product is intended to be connected to a DC power source that can be classified as a secondary circuit in accordance with applicable national requirements for Information Technology Equipment. Generally, these requirements are base