It’s easy to see the difference in quality. Ducane heating and cooling products are designed to make life more comfortable for you and your customers. • Ducane heating and cooling products are built with a commitment to quality. • Long-lasting components and durable construction provide years of trouble-free service. • Simple installation and maintenance reduce your service time. • Energy-efficient engineering reduces your customers’ utility bills*, while no-hassle warranties provide peace of mi
See limited warranty for details. 2AC13 Split System Air Conditioner 13 2 AC 13 B 24 P - 1 A Model Number Guide Refrigerant – 2 = R22 AC = Condenser 13 - 13 SEER Nominal BC = Wire Guard + 76dBA LC = Louvered + 76dBA B = Wire Guard L = Louvered Minor Revision Code Major Revision Code Voltage P - 208-230v/60hz Single Phase Nominal Capacity 24 - 24,000 Btuh Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Maximum Over Current Device (amps) Compressor Fan Motor Refrig. Charge (oz.): Weight (
When used in conjunction with a two-stage thermostat, the Fits-All 92V will only produce the amount of heat necessary to keep the home comfortable, helping minimize energy consumption for lower utility bills. In "Fan On" mode the variable speed blower motor can consume up to 2/3 less energy than a traditional PSC blower motor, allowing you to optimize add-on indoor air quality products year round. Built To Last Durable Crimp-TiteTM aluminized steel heat exchanger resists corrosion with crimped
See limited warranty document for details. B Model 2HP14 Split System Heat Pump seer 14 2 HP 14 B 36 P - 1 A Model Number Guide Refrigerant – 2 = R22 AC = Condenser HP = Heat Pump 14 - 14 SEER Nominal Family / Coil Protection B = Non-Louvered L = Louvered A = Service Level Revision Code Voltage P - 208-230v/60hz Single Phase Nominal Capacity 36 - 36,000 Btuh Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Maximum Over Current Device (amps) Compressor Fan Motor Refrig. Charge (oz.): Weig
Circuit Amp. Max. Fuse (amps)* Compressor Fan Motor Refrig. Charge (oz.)** Weight (lbs.) Rated Load (Amps) Locked Rotor (Amps) Full Load Amps Rated HP Nom. RPM Wire Guard/ Louvered 4AC13(B,L)18P-1A 208-230/60/1 197 - 253 11.9 20 9.0 48 0.7 1/10 1075 72 129/139 4AC13(B,L)24P-1A 208-230/60/1 197 - 253 17.5 25 13.4 58.3 0.7 1/10 1075 75 130/140 4AC13(B,L)30P-1A 208-230/60/1 197 - 253 16.7 25 12.8 64 0.7 1/10 1075 98 166/179 4AC13(B,L)36P-1A 208-230/60/1 197 - 253 18.7 30 14.1 77 1.1 1
100 13,200 7.70 16,700 3.44 10,400 2.30 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 E(C,M,U)1P29NA MPGAV050,075 13.5 11.5 18,100 13,200 7.70 16,700 3.44 10,400 2.30 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 E(C,M,U)1P36NA,NB CMPEV050, 075, 100 13.5 11.5 18,200 13,300 7.80 16,700 3.48 10,400 2.34 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 E(C,M,U)1P36NA,NB,NC MPGAV050,075,100,125 13.5 11.5 18,200 13,300 7.80 16,700 3.48 10,400 2.34 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 4HP13*24 RBCS2M24C*****P -
Circuit Amp. Max. Overcurrent Device (amps) Compressor Fan Motor Refrig. Charge (oz.) Weight (lbs.) Rated Load (amps) Locked Rotor (amps) Rated Load (amps) Rated HP Nom. RPM Wire Guard/ Louvered 4HP13*18P 208-230/60/1 197/253 11.90 20 9.0 48 0.7 1/10 1075 117 151/166 4HP13*24P 208-230/60/1 197/253 11.10 15 8.3 43 0.7 1/10 1075 130 169/185 4HP13*30P 208-230/60/1 197/253 14.4 20 10.6 54 1.1 1/5 1075 159 186/203 4HP13*36P 208-230/60/1 197/253 19.6 30 14.7 74 1.2 1/4 1075 151 197/208 4HP13*42P 208-2
Outdoor Model Indoor Model Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 4HP13*18P1A RBCS2M18C *****P Btuh 21,500 20,200 18,700 17,500 16,800 16,300 15,400 14,300 13,100 12,300 10,900 10,500 9,800 8,700 Kw 1.58 1.55 1.53 1.50 1.49 1.480 1.47 1.46 1.44 1.43 1.42 1.41 1.40 1.39 COP 3.98 3.82 3.58 3.42 3.30 3.22 3.06 2.86 2.66 2.52 2.24 2.18 2.04 1.84 4HP13*24P1A RBCS2M24C *****P Btuh 24,100 23,500 22,800 22,000 21,400 20,800 19,200 17600 16200 14700 13000 11800 11200 9200 K
For assistance or additional information, consult a qualified installer or service agency. WARNING Installation and servicing of air conditioning equipment can be hazardous due to internal refrigerant pressure and live electrical components. Only trained and qualified service personnel should install or service this equipment. Installation and service performed by unqualified persons can result in property damage, personal injury, or death. WARNING If this unit is to be installed in a mobile or
They are designed to help you use significantly less energy than units installed as recently as five years ago. Built To Last Attractive louvered panels protect the coils and are easy to service, while the compressors are designed for reliable and efficient money-saving performance. Our field-proven, adjustable time/temperature defrost control ensures peak performance is maintained during freezing temperatures. Factory-installed, bi-flow liquid line filter driers protect the compressor from c