Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  

Goodman Mfg ANSI Z21.47CSA-2.3

Descargado: 2Tamaño del archivo: 2 mb    Fabricar: Goodman Mfg  
Categoría: Los calentadores de gas

Unit factory shipped with sheave set at 2.5 turns open. Air flow tables represent dry coil with filters installed; SCFM correction factor for wet coil is 4%. 24 APPENDIX A BLOWER PERFORMANCE DATA BELT DRIVE - HIGH STATIC CPG180 HIGH STATIC BELT DRIVE ESP, In H2O TURNS OPEN 0 1 2 3 4 5 6 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1.0 ---- -- - --- -- - --- 6690 3.69 6008 3.02 5321 2.43 1.2 ---- -- - --- -- 6653 3.95 5922 3.22 5182 2.58 ---- 1.4 ---- -- - - 6634 2.80 5857 3.44 5056 2.

Goodman Mfg CVC9/95

Descargado: 0Tamaño del archivo: 2 mb    Fabricar: Goodman Mfg  
Categoría: Eléctrico

C US ® RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than when the unit

Goodman Mfg CPH COMMERCIAL SS-CPH90-150

Descargado: 26Tamaño del archivo: 1 mb    Fabricar: Goodman Mfg  
Categoría: Los acondicionadores de aire

ProduCt SPeCifiCationS ProduCt SPeCifiCationS nomenClature CPH0900303B***A* 1234,5,67,8,910111213141516RevisionLevelsMajor&MinorBrandFactory-­.Installed Op7onsCCommercialXNo OpConsANon-­.powered convenience outletConfigura7onBPowered convenience outletPPackaged UnitCLow-­.ambient kitDReturn aismoke detectorApplica7onESupplyairsmoke detectorCCoolingFNon-­.powered convenience outlet; GGasHeatLow-­.ambient kitHHeat PumpGNon-­.powered convenience outlet; Return aismoke detectorNominal Gross Cooling

Goodman Mfg A/GPG13 M

Descargado: 8Tamaño del archivo: 1 mb    Fabricar: Goodman Mfg  
Categoría: Los acondicionadores de aire

IO-357A 5151 San Felipe, Suite 500, Houston, TX 77056 3/10 © 2009 - 2010 Goodman Manufacturing Company, L.P. *NOTE: Please contact your distributor or our website for the applicable Specification Sheet or Technical Manual referred to in this manual. This Forced Air Central Unit Design Complies With Requirements Embodied in The American National Standard / National Standard of Canada Shown Below. ANSI Z21.47•CSA-2.3 Central Furnaces RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. ATTENTION INSTALLI

Goodman Mfg CPC CONVERCIAL SS-CPC90-150

Descargado: 6Tamaño del archivo: 1 mb    Fabricar: Goodman Mfg  
Categoría: Los acondicionadores de aire

Available as a factory-installed option on 3- to 12A-ton units. Hail guards are standard on 15- and 20-ton units. C • Stainless-Steel Heat Exchanger (CPG units only): A tubular heat exchanger made of 409-type stainless steel is installed in the unit. D • Ultra-Gold Condenser Coil: Offers increased corrosion resistance of the condenser coil. Not available for 15- & 20-ton units. • Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to J 6-ton units, cooling

Goodman Mfg TSTATG2111

Descargado: 34Tamaño del archivo: 1 mb    Fabricar: Goodman Mfg  
Categoría: Los termostatos

Set the thermostat mode to “OFF” prior to changingsettings in setup or restoring Factory Defaults. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4Z95 Thermostat TSTATG2111 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE FCc Page i How to Use This Manual A Con

Goodman Mfg GPH15M

Descargado: 10Tamaño del archivo: 1 mb    Fabricar: Goodman Mfg  
Categoría: Equipos de Bombeo

2 Product Specifications ............................................................ 3 Expanded Cooling Data .......................................................... 4 Expanded Heating Data........................................................20 Airflow Data .......................................................................... 23 Auxiliary Heating Data.......................................................... 24 Heat Kit Electrical Specs.................................................

Goodman Mfg HPAW155

Descargado: 5Tamaño del archivo: 977 kb    Fabricar: Goodman Mfg  
Categoría: Equipos de Bombeo

10.3 Antifreeze To avoid the risk of the freezing in the external section of the heating system (i.e. the flexible hoses, condenser and circulating pump within the heat pump casing) in the event of power failure during winter months, a suitable domestic heating system antifreeze should be used. This is added to the system water when finally filling the heating system. Full instructions are supplied with the system antifreeze, but immediate information can be obtained from and IMPORTANT As with a

Goodman Mfg HPAW130

Descargado: 11Tamaño del archivo: 977 kb    Fabricar: Goodman Mfg  
Categoría: Equipos de Bombeo

The COP data given above is based on 7.C ambient air and 35.C water temperature. This information should be used as guidance only and notto estimate the COP at other temperatures. ! NOTE Figure 2-5: Grant HPAW65 Figure 2-8: Grant HPAW130 Figure 2-6: Grant HPAW85 Figure 2-7: Grant HPAW110 Figure 2-9: Grant HPAW155 2.5 Pump Curves Pump Head (metres) Pump Head (metres) 6 5 4 3 2 1 0 Wilo-Classic Star 0 0.5 1 1.5 2 3) Flow (m3/h) Flow (m3/h) Star-RS15/6.25/6 2.6 Heat Pump Operating Sequences Pump OF

Goodman Mfg HPAW110

Descargado: 7Tamaño del archivo: 977 kb    Fabricar: Goodman Mfg  
Categoría: Equipos de Bombeo

When tracing a fault code, use the table of fault codes on page 32 to help you. As often as not, it will be a wire that has become loose or disconnected. Check all wires for security before calling our helpline for assistance. There are 6 sensors in total. The ATC have black tails and the BTC have blue tails. The resistance/temperature tables for the ATC and BTC sensors are given in Figures 13-2 and 13-3. 6. The pressure gauge on the side of the heat pump measures refrigerant pressure not water





Categoría