Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↑  

Heat & Glo LifeStyle CRESCENT II CRESCENT II

Descargado: 6Tamaño del archivo: 5 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09 B. Lighting Appliance IPI Ignition FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an intermittent pilot ignitio

Heat & Glo LifeStyle RUTHERFORD 50

Descargado: 6Tamaño del archivo: 5 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

• Check fireplace opening for square to ensure proper fit of glass doors. Measure diagonals of fireplace opening to make sure they are equal. Top piece must overlap bottom piece Metal strips are placed 2 in. (51 mm) under the front of the fireplace and must extend beyond the front and sides of fireplace opening by 2 in. (51 mm). 1 in. (25 mm) overlap Minimum Figure 7.1 Position the Protective Metal Hearth Strips 2 in. 1 in. (25 mm) min. (51 mm) Raised Platform Floor overlap 2 in. (51 mm) Figure

Heat & Glo LifeStyle SL-950TV-IPI-E

Descargado: 1Tamaño del archivo: 5 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance. • Gas line may be run through knockout(s) provided. • The gap between supply piping and gas access hole may be caulked with high

Heat & Glo LifeStyle SL-550TV-IPI-E

Descargado: 2Tamaño del archivo: 5 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

Adjust air shutter for longer vertical runs. See Figure 14.6. • Loosen the wing nut. • Push the air handle in to close the air shutter. • Pull the air handle out to open the air shutter. • Tighten the wing nut. NOTICE: If sooting occurs, provide more air by opening the air shutter. Figure 14.5 Fixed Glass Assembly Figure 14.6 Air Shutter G. Fixed Glass Assembly Removing Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is

Heat & Glo LifeStyle SL-750TV-IPI-E

Descargado: 0Tamaño del archivo: 5 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

The fireplace should be inspected before use and at least annually by a professional service person. The following tasks may be performed annually by the homeowner. If you are uncomfortable performing any of the listed tasks, please call your dealer for a service appointment. More frequent cleaning may be required due to lint from carpeting or other factors. Control compartment, burner and circulating air passageway of the fireplace must be kept clean. CAUTION! Risk of Burns! The fireplace shoul

Heat & Glo LifeStyle EM-485T

Descargado: 2Tamaño del archivo: 4 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

Insert the top flange of the heat shield through the electrical knockout hole from the inside (Figure 7.9). • Attach the junction box bracket to the side of the appliance. See Figure 7.10. Secure with the screws provided in the fastener package. Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08 Figure 7.9 Attach the Heat Shield Bend this tab down 90 degreesBend this half tab down 90 degrees Slide the flanges of the junction box through the slots in the bracket. Figure 7.6 Prepare Junction Box

Heat & Glo LifeStyle EM-485TH

Descargado: 3Tamaño del archivo: 4 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

Flange Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.6 Installing an ST375 Square Termination Cap • TR344 Round Termination Cap • ST375 Square Termination Cap • TR342 Round Telescoping Termination Cap 35 Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08 Chimney Pipe Chase Top Termination Cap Chase 3 in. (76 mm) Maximum top of chase to top of chimney section Collar 2 in. (51 mm) Minimum Height Termination cap pipe and chimney section must overlap 1-1/2 in. (38

Heat & Glo LifeStyle EM-415H

Descargado: 5Tamaño del archivo: 4 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

• Wet, unseasoned wood can cause accumulation of creosote. The majority of the problems fireplace owners experience are caused by trying to burn wet, unseasoned wood. • Wet, unseasoned wood requires energy to evaporate the water instead of heating your home, and • Evaporating moisture cools your chimney, accelerating formation of creosote. • Split to 6 in. (152 mm) or less • Air dry to a moisture content of around 20% - Soft wood - about nine months - Hard wood - about eighteen months NOTICE: Se

Heat & Glo LifeStyle EM-415

Descargado: 17Tamaño del archivo: 4 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: chimeneas

• A gas log set must incorporate a gas shutoff. • Gas Log set requires the damper to be locked fully open. • Knockouts are provided on both sides of the fireplace and in refractories for 1/2 in. (13 mm) iron pipe. • Seal refractory around pipe with fireplace mortar or a high temperature, noncombustible sealant. B. Wood Burning Inserts WARNING! Risk of Fire! Improper installation of wood inserts may cause fireplace or chimney system to overheat. If a wood burning insert is being installed in this

Heat & Glo LifeStyle TIARAP-BK

Descargado: 0Tamaño del archivo: 4 mb    Fabricar: Heat & Glo LifeStyle  
Categoría: Los calentadores de gas

Optional High Wind Termination Cap Secure Flashing with Non-Hardening Sealant and Roofing Nails Figure 5.15 Step 9. Twist-lock the vent cap and seal. Note: For multi-story vertical installations, a ceiling firestop is required at the second floor, and any subsequent floors (Figure 5.16). The opening should be framed to 10 in. x 10 in. (254mm x 254mm) inside dimensions, in the same manner as shown in Figure 5.13 on page 16. MIN. 1 in. (25mm) CLEARANCE CEILING FIRES TOP NAILS MIN. 1 in. (25mm) CLE





Categoría