Power supply to the furnace must be N.E.C. Class 1, and must comply with all applicable codes. and/or The Canadian Electric Code CSAC22.1. Use a separate fused branch electrical circuit containing properly sized wire, minimum 12 gauge, and fuse or circuit breaker. The furnace must be electrically grounded in accordance with local codes or, in their absence, with the latest edition of: The National Electric Code, ANSI NFPA 70. The fuse or circuit breaker must be sized in accordance with the maxim
A, 05/2007 A French manual is available upon request. Order P/N 775,221CF. Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numero de la piece 775,221CF. In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter • See Table of Contents for location of additional Commonwealth of Massachusetts requirements Report No. 050-S-18b-5 Medina™ (MED) WARNINGS • Hot! Do not touch! The glass and surfaces of this appliance w
Lennox an international organisation with world wide distribution takes pride in supplying you with this product. CONTENTS PAGECONTENTS . PRODUCT RANGE 2-3 . SYSTEM CONFIGURATION 4 . GENERAL DESCRIPTION 5 . SPECIFICATIONS 6-9 . ELECTRICAL DATA 10-11 . ELECTRICAL CONNECTIONS 12-14 . INDOOR MOTOR FAN CHARACTERISTICS 15 . OPERATING LIMITS 16 . REFRIGERANT CONNECTIONS 17-19 . DIMENSIONS AND SETTING UP TEMPLATES OUTDOOR UNIT 20 . DESCRIPTION OUTDOOR UNIT 21-22 . ENTRANCE STANDARD/ OPTIONAL OUTDOOR UN
You will do this with each front baffle board with one to the right side of the firebox and one to the left side of the firebox. Confirm that the baffle blanket is directly on top of the baffle boards and that it does not protrude beyond the front baffle or front baffle boards as shown in Figure 4. Front View See the following for brick sizes *Fits against the back of the firebox. Note: These bricks may be slightly smaller to adjust for steel and firebrick tolerances beyond our control. Be sure
........................................................................................................................................................................................................................................r. Ne pas vous servir des telephones se trouvant dans le batiment ou vous trouvez. ................................................................................................................ un voisin. Suivez les instructions du fournisseur. .....................
Do not use these appliances if any part has been under water. Immediately call a qualifi ed, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water. Ne pas utiliser cet appareil s’il a ete plonge, meme partiellement, dans l’eau. Appeler un technicien qualifi e pour inspecter l’appareil et remplacer toute partie du systeme de commande et toute commande qui a ete plongee dans l’eau. Only trim kit(s) su
• (1) Hood (behind the top louver assembly). INTRODUCTION The Millivolt appliances have a millivolt gas control valve with piezo ignition system. If any optional accessories that will require electrical power are to be installed, the electrical power must be provided at the time of appliance installation. The Electronic appliances are designed to operate on natural or propane gas. An electronic intermittent pilot ignition system provides safe, effi cient operation. External electrical power is r
The location should also be free of electrical, plumbing or other heating/air conditioning ducting. Be aware that this is a heat producing appliance. Objects placed above the unit are exposed to elevated temperatures. Do not insulate the space between the appliance and the area above it (see Figure 9 on Page 8). The appliance must be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. Howev
(406 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the 16 in. (406 mm) must be measured from the drywall surface. It is important that this dimension be exact. Headers may be in direct contact with the appliance top standoff spacers, but must not be supported by them or notched to fit around them. All construction above the appliance must be self-supporting. DO NOT use the appliance for structu
Les enfants et les adultes devraient etre informes des dangers que posent les temperatures de surface elevees et se tenir a distance afi n d’eviter des brulures ou que leurs vetements ne s’enfl amment. DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT PLUS® B-VENT GAS FIREPLACES (MPB33/3