Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↓  

Field Controls G4702

Descargado: 8Tamaño del archivo: 36 kb    Fabricar: Field Controls  
Categoría: Aire

An alternate method would be to use wall anchors. Whichever method you use, make sure the air cleaner is mounted in a sturdy fashion to prevent it from pulling loose. © 1997 Grizzly Industrial, Inc. G4702 & G4705 INSTALLATION INSTRUCTIONS The G4702 & G4705 Air Cleaners can be mounted on the floor, wall or a ceiling; whichever place is convenient. If mounting on a wall or ceiling, we recommend attaching the air cleaner to the wall or ceiling studs using sheetrock screws. This will require at

Field Controls G4705

Descargado: 4Tamaño del archivo: 36 kb    Fabricar: Field Controls  
Categoría: Aire

This will require at least four holes be drilled corresponding to the stud spacing. An alternate method would be to use wall anchors. Whichever method you use, make sure the air cleaner is mounted in a sturdy fashion to prevent it from pulling loose. © 1997 Grizzly Industrial, Inc.

Field Controls CC 2000

Descargado: 2Tamaño del archivo: 163 kb    Fabricar: Field Controls  
Categoría: Aire

1706 Canterbury Rd Greenville, NC 27858 Ph. 252.355.6789 Oysterdoctor@aol.com Efficiency Of Bacterial Disinfection By A Duct Mounted UV-AireO Air Purifier For: Table of Contents Table of Contents Background ..........................................................................................................................3 Organism.........................................................................................................................3 Testing Structure.....................

Field Controls UV-AIRE 46512300

Descargado: 0Tamaño del archivo: 177 kb    Fabricar: Field Controls  
Categoría: Aire

(See Figure 1) 2. Bend tabs outward as shown in Figure 2. 3. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See Figure 3) 4. Remove the cut piece of duct. (See Figure 4) 5. Bend both tabs down and through duct at first bend point. (See Figures 5 & 6) 6. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 7 & 8) 7 Using a screwdriver or pointed object, locate mountin

Field Controls UV-AIRE UV-16R

Descargado: 0Tamaño del archivo: 177 kb    Fabricar: Field Controls  
Categoría: Aire

(See Figure 1) 2. Bend tabs outward as shown in Figure 2. 3. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See Figure 3) 4. Remove the cut piece of duct. (See Figure 4) 5. Bend both tabs down and through duct at first bend point. (See Figures 5 & 6) 6. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 7 & 8) 7 Using a screwdriver or pointed object, locate mountin

Field Controls FC-2000

Descargado: 6Tamaño del archivo: 244 kb    Fabricar: Field Controls  
Categoría: Aire

7. Drill the marked mounting holes with a 1/8 inch diameter drill bit. Remove the marked filter opening with metal cutting shears or equivalent. 8. Attach filter cabinet to the appliance or duct work using #8 X 1/2 inch long sheet metal screws or pop rivets. Seal the housing connections with aluminum duct tape or equivalent. 9. Remove media filter from the plastic bag and discard the plastic bag. TIP: Write the installation date on filter next to directional arrow for future filter replacement r

Field Controls FC-1400

Descargado: 3Tamaño del archivo: 244 kb    Fabricar: Field Controls  
Categoría: Aire

*The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction. WARNING: Read the installation instructions carefully and completely before proceeding with the installation. GENE

Field Controls CLEARWAVETM WATER CONDITIONER CW-HD-4

Descargado: 15Tamaño del archivo: 287 kb    Fabricar: Field Controls  
Categoría: Los acondicionadores de aire

(see Figure 1) For pipe mounting, the wall mount tabs should be removed from the mounting brackets. (see Figure 2) 2. Plug the antennas into each end of the housing, to the appropriate wire wrap connections (e.g. “CW” for clockwise wrapping and “CCW” for counter clockwise wrapping). If longer wires are needed, up to 50 feet of 12Ga stranded wire can be added to the antenna wires with an insulated butt end wire connector or they Page 2 Page 3 can be replaced with 70 feet of 12Ga stranded wire. PR

Field Controls Clearwave Water Conditioner CW-HD-2

Descargado: 1Tamaño del archivo: 298 kb    Fabricar: Field Controls  
Categoría: Depuradores de agua

With ClearWave™, the electric field generated is always being applied to the water, while a magnetic field relies on the movement of water to produce the electric potential changes. Low frequency waveforms are emitted through two coiled wires attached to the outside of the water pipe. As a result of these waveforms, the two coils are constantly inducing a voltage into the water in the area of the ClearWave™. When one coil induces a positive voltage the other coil induces a counteracting negative

Field Controls UV-Aire Air Purifying System UV-500C

Descargado: 0Tamaño del archivo: 370 kb    Fabricar: Field Controls  
Categoría: Aire

Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 2 7. Insert the ceramic tip of the lamp into the UV port and twist the lamp connector clockwise to lock in place. (See Figure 3) Figure 3 8. With unit still UNPLUGGED, insert the lamp power connector into the recessed receptacle on the unit. (See Figure 4) Figure 4 9. Close the access do