Iniciar sesión:
Clasificado: Nombre ↑   Descargas   Tarifa   Tamaño ↓  

LST 249020

Descargado: 0Tamaño del archivo: 68 kb    Fabricar: LST  
Categoría: Detector de incendios

In case of alarm, the unique identification of the activated conventional detector is achieved by transmitting the address to the fire detection control panel Specifications Current consumption at 24 V 18mA (active) Ambient temperature -5°C to +50°C Dimensions L x W x H 32 x 19 x 5 (mm) Weight 10g Order number 249020 Order name Address Module/Conv. NG58-1 Apart from the detector address, on Fire Detection Control Panels BC216 a possibly parameterised element text (for example with the

LST ABF216-1

Descargado: 3Tamaño del archivo: 73 kb    Fabricar: LST  
Categoría: Detector de incendios

It provides the same ease of use and offers the same information (LED indicators and four-line text display) as a sectional control panel allowing operation. Depending on the parameter setup, all or selected GSSnet members can be operated, and the events of all or selected GSSnet members are displayed. Specifications Operating voltage 15 -31VDC Current consumption at 24V 140mA (quiescent) GSSnet line length max. 1200m between two adjacent members (with category 5 cable) Ambient temperatu

LST 5351TE

Descargado: 18Tamaño del archivo: 76 kb    Fabricar: LST  
Categoría: Detector de incendios

It complies with Class A2S and can be used up to a room height of 6m. Addressable conventional technology is used for alarm transmission to the fire detection control panel. The detector addressing can be achieved in 2 ways: • A detector with an Address Module NG58-1 can be individually identified by the suitable control panel. • An address, which has been stored in the detector by means of the Remote Programming and Test Unit, is displayed on the Zonal Display Unit S300ZDU Specifications

LST 2351E

Descargado: 3Tamaño del archivo: 77 kb    Fabricar: LST  
Categoría: Detector de incendios

The modern design of the measurement chamber allows to reliably evaluate the characteristics of fire. An internal drift compensation adjusts the alarm threshold by continually evaluating the contamination of the detector. With that, the sensitivity of the detector is kept constant for a long time. Addressable conventional technology is used for alarm transmission to the fire detection control panel. The detector addressing can be achieved in 2 ways: • A detector with an Address Module NG58-1

LST 5351E

Descargado: 2Tamaño del archivo: 77 kb    Fabricar: LST  
Categoría: Detector de incendios

The intelligent evaluation of these data allows the early detection of spreading fires. The detector complies with Class A1R and can be used up to a room height of 7.5m. Addressable conventional technology is used for alarm transmission to the fire detection control panel. The detector addressing can be achieved in 2 ways: • A detector with an Address Module NG58-1 can be individually identified by the suitable control panel. • An address, which has been stored in the detector Specification

LST 4351E

Descargado: 0Tamaño del archivo: 77 kb    Fabricar: LST  
Categoría: Detector de incendios

It complies with Class BS and can be used up to a room height of 6m. Addressable conventional technology is used for alarm transmission to the fire detection control panel. The detector addressing can be achieved in 2 ways: • A detector with an Address Module NG58-1 can be individually identified by the suitable control panel. • An address, which has been stored in the detector by means of the Remote Programming and Test Unit, is displayed on the Zonal Display Unit S300ZDU Specifications ■

LST B401RM

Descargado: 0Tamaño del archivo: 78 kb    Fabricar: LST  
Categoría: Detector de incendios

Due to its robust multi-wire screw terminals, the detectors can be wired with ease, thus achieving a secure and durable connection. The base provides the possibility to easily connect an external remote indicator, and has been designed for surface mounting in dry rooms. For special applications a range of accessories (for moist room, false ceiling or flush installation) is available. Specifications Ambient temperature -20°C to +70°C Relative humidity 10 - 93% (no condensation) Dimensions 0

LST AC-58000-300

Descargado: 0Tamaño del archivo: 81 kb    Fabricar: LST  
Categoría: Detector de incendios

It is an ideal supplement to common smoke detectors because it is insensitive to the usual vapors and household products, in low concentrations. The carbon monoxide detector does not respond to smoke particles and heat, and therefore it shall only be used in addition to smoke or heat detectors. Besides, the size of the fire area shall not exceed 50m2. The proven ADM loop techno protocol establishes a perm Operating voltage logy with Apollo/Discovery The detector can be attached to different typ

LST ASA-45681-210

Descargado: 0Tamaño del archivo: 82 kb    Fabricar: LST  
Categoría: Detector de incendios

Due to its robust multi-wire screw terminals, the detectors can be wired with ease, thus achieving a secure and durable connection. The base also provides a possibility for the easy connection of remote indicators. The detector address is selected by means of a code Specifications Ambient temperature -20°C to +60°C (no condensation or icing) Relative humidity 10 - 95% (no condensation) Dimensions 0 x H 100 x 15 (mm) Colour white Weight 50g Order number 246025 Order name Detector Base/A

LST AW-55000-420

Descargado: 0Tamaño del archivo: 82 kb    Fabricar: LST  
Categoría: Detector de incendios

Depending on the parameter setup in the fire detection control panel, the detector can operate either as maximum heat detector with an alarm temperature of 55°C, or as rate-of-rise heat detector with a maximum temperature of 55°C. The proven ADM loop technology with Apollo/Discovery Specifications Supply through loop voltage Current consumption max. 250|jA (quiescent) Ambient temperature -20°C to +70°C Relative humidity 0 - 95% (no condensation) Dimensions 0 x H 100 x 42 (mm) Colour white





Categoría