3 Peak Performance ................................ 4 Problem Solver ..................................... 5 Extra Energy Tips ................................. 5 Service Information ............................... 6 Optional Extended Warranty Optional Extended Warranties are available from the Manufacturer. The Extended Warranty can be purchased from your dealer and is in effect when you have received an Extended Warranty Certificate from Trane. No additional warranty, either written or implied
That’s why attempts at “do-it-yourself” repairs on an in-warranty unit may void the remainder of your warranty. Other than performing the simple maintenance recommended in this manual, you should not attempt to make any adjustments to your heat pump system. Your dealer will be able to take care of any questions or problems you may have. Help ensure top efficiency by cleaning or replacing the filter monthly.* When the heat pump circulates and filters the air in your home, dust and dirt particles
Buildup of snow and ice can restrict airflow. As soon as possible after accumulation, clean snow from the area around the heat pump. To avoid overworking your unit, do not plant flowers or shrubbery right next to it. Also, make sure that nothing is stacked against the sides of the unit or draped over it. 22-5156-04-0804 (EN) 3 Keep your heat pump looking new for years. Clean the enamel finish of your heat pump with soap and water. For stubborn grease spots, use a household detergent. Do not use
Util. Volt Max Util. Volt Compressor Data No. of Comp Aux Pump Amps Desup Pump RLA MCA Max FuseRLA LRA GSWD024 208-230/60/1 197 253 11.4 56.0 1 2.5 0.4 17.2 25 GSWD036 208-230/60/1 197 253 15.0 73.0 1 2.5 0.4 21.7 35 GSWD042 208-230/60/1 197 253 18.4 95.0 1 2.5 0.4 25.9 40 GSWD048 208-230/60/1 197 253 20.4 109.0 1 2.5 0.4 28.4 45 GSWD060 208-230/60/1 197 253 28.0 169.0 1 2.5 0.4 37.9 60 GSWD072 208-230/60/1 197 253 32.1 169.0 1 2.5 0.4 43.0 70 WSHP-SVX02A-EN Pre-Start Checklist Pre-Start-up Chec
Connecting a Loop Pump Kit Closed Loop System All piping external to the unit is the responsibility of the installer. The water pipe installation must be done in accordance with local codes. If no local code applies, national codes should be followed. It is the contractor’s responsibility to know and adhere to all applicable codes. Water inlet and outlet to the unit’s water- to-refrigerant heat exchanger are clearly marked on the submittal drawings found on pages 7 through 9. The supply and retu
If indoor storage is not possible, the following provisions for outdoor storage must be met: 1. Place the unit(s) on a dry surface or raise above the ground to assure adequate air circulation beneath the unit. 2. Cover the unit(s) with a water proof tarp to protect them from the elements. 3. Make provisions for continuous venting of the covered units to prevent moisture from standing on the unit(s) surfaces. Wet interior unit insulation can become an amplification site for microbial growth (mold
It is designed to deliver what we call TRANE AirTM throughout your home. It delivers air that is meticulously filtered and cleaned of up to 99.98% of allergens to provide maximum comfort. You and your family can breathe easier than ever before. 32-5038-01 User’s Information Figure 1. COMPONENTS OF THE TRANE CLEANEFFECTSTM 4 3 1 3 Fig. 1 1) Pre-filter - Traps large particles such as hair and lint before they can enter the cell section. 2) Field Charger - Charges the contaminants. Only to be servi
22-1682-05-0802 (EN) General Features NATURAL GAS MODELS Central heating furnace designs are certified by the International Approval Services (IAS) for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation.
TFM210A9FR0 [ ] Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... TFM245A9FR0 [ ] Electronic Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..................................................... TFP145A9FR0 [ ] Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFP175A9FR0 [ ] Electronic Air Filter
BAYFLTR200 [ ] Filter Kit/Horizontal Conversion TUY060, 080-R ......................................................................................................... BAYFLTR203 [ ] Filter Kit/Horizontal Conversion TUY100-R ................................................................................................................ BAYFLTR204 [ ] Filter Kit/Horizontal Conversion TUY120-R .........................................................................................................