Herramientas requeridas: desarmador # 2 de Philips Specifications Model........................................2ZRP8.............2ZRP9 Motor......................................Honda............Honda Potencia Nominal (Vatios CA).................................5000...............6500 Potencia Nominal Intermitente (Vatios CA).......6000...............7500 Voltaje Nominal (CA)......120V/240........120V/240 Maximo Amperaje..............35.0/25.0........62.5/31.3 Continuo Amperaje............41.7/2
VEA CONCESIONARIO PARA SERVICIO INMEDIATAMENTE. 11. Si recipientes examine correcto, empuje el boton de colocar para restablecer potencia. Debe oir o sentir un taconazo distincto cuando este es completo. SI RECIPIENTES NO COLOCAR CORRECTO, NO USE RECIPIENTES. VEA CONCESIONARIO PARA SERVICIO INMEDIATAMENTE. 12. Si unidad tiene control de flojear a posicion de ON. Ahora cargas pueden aplicar a la unidad. NOTA: Este motor esta protegido con un sistema que para el motor cuando el aceite alcanza un n
The gas supply to the infra-red heater must be connected and tested in accordance with national, state, provincial and local codes along with the guidelines in this manual. Refer to the latest edition of the ANSI Z223.1 (NFPA 54) Standard. Important! Before connecting the gas supply to the infra-red heater(s): • Check for conditions such as drafts or other variables which might cause excessive movement of the unit and cause damage to the gas connection. Ensure that the unit is securely mounted a
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain these instructions for future reference. Dayton® Patio Heaters Description Dayton high-intensity patio heaters become highly efficient generators of infrared radiation by heating a ceramic refractory material to incandescence. The principal operation is to pass a gas-air mixture through a perforated ceramic refractory, and ignite it o
The surface must be level. Protect generator from heavy dust, sand, dirt, rain, or snow. Do not locate generator near standing water and snow. Make sure area is well-vented. Only responsible adults should use generator. Never let anyone operate generator without proper instructions. NOTE: If oil level is too low, oil alert system will keep engine from starting (See “Oil Alert System,” page 5). Make sure oil level is full before starting. See “Engine Oil,” page 10. Before starting the engine, dis
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. ® Dayton Professional- Duty Electric Generators Description Dayton professional-duty generators are rugged and compact to provide dependable, trouble-free service. The alternators are brushless with revolving fields. Honda gasoline engines provide long life under heavy use. Overhead valves (OHV) prov
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. General Safety Information ▲warnings WARNING: Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon mono
IMPORTANT: Every possible circumstance that might involve a hazard cannot be anticipated. The warnings in this manual and on tags or decals affixed to the unit are therefore not all-inclusive. If a procedure, work method, or operating technique not specifically recommended by Dayton is used, you must make sure it is safe for you and others. You should also ensure that equipment will not be damaged or made unsafe by the operating or maintenance method you choose. Carbon monoxide poisoning may lea
Regulate the natural gas supply down from a minimum 6 inches water column to a maximum of 1/2 psi. The natural gas supply capacity should be able to supply a minimum of 100 cubic feet of gas at pressure for each heater connected to the system. Consult your natural gas supplier for proper sizing of the natural gas supply lines. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the National Fuel Gas Code Handbook, NFPA54/ANSI Z223.1 and the Natural Gas I
4. Remove and wash in clean fuel. Blow dry and replace. 5. a. Clean by blowing compressed air through nozzle from outlet end of nozzle. b. Replace nozzle if cleaning does not solve the problem. 6. Move heater to warmer environment until fuel flows freely. 7. Be sure air filters are clean. 8. Check fuel filter for air leaks and for tightness of fit where it is connected to fuel line. Ignition Troubles WARNING: DISCONNECT HEATER CORD! HIGH VOLTAGE! Heater will not ignite, but motor runs for a