Typically, during light freeze conditions, circulating (moving) water will not freeze. In areas where freezing conditions are prevalent and sustained, the heat pump must be winterized as follows: 1) Disconnect all electrical power to the heater; turn off circulating pump. 2) At the two (2) connection unions, disconnect the plumbing to the heater (removal is counter-clockwise). 3) If your unit has an external drain plug, remove plug. This plug would be located at lower, front corner of heater (po
CAUTION - Failure to heed the following may result in equipment damage. . Improper water chemistry can cause damage to pump, filter, pool shell, etc. To avoid equipment damage, maintain Pool/Spa water per standards detailed later in this manual. . Water flow exceeding max flow requires a bypass. Damage due to excessive water flow will void warranty. SAVE THESE INSTRUCTIONS SPECIFICATIONS Specification Description Electrical Service See data plate attached to front cover or behind front access pa
If error persists, proceed to next step. Filtration Dirty Step 2: Confirm filtration system is clean. Backwash if needed. If error persists, proceed to next step. Possible Water Pressure Switch Step 3: Request Service “CEr” Error Communication Fault N/A Request Service “CSE” Error Control System Error N/A Request Service “dPC” Error Defrost Sensor Shorted N/A Request Service “dPO” Error Defrost Sensor Open N/A Request Service “FS” Error Unit in defrost mode. Normal defrost mode Step 1: If error
Eastern time, Monday through Friday Fax (727) 821-7471 Please have your model and serial numbers available when contacting AquaCal AutoPilot for questions, service, or parts. SAFETY For personal safety, and to avoid damage to equipment, follow all safety instructions displayed in this guide. Repair and service of your heat pump must be performed by qualified service personnel. Failure to properly install, operate, maintain, or repair the heat pump will void factory warranty. Please note "WARNING
“xx°” Current Water Temperature (Example 78°) Temperature can be set from 45° F to 104° F. This can be displayed in Fahrenheit or Celsius depending on programming. FLO No water flow through Heat Pump This can be a normal display depending on system settings. See “Troubleshooting” if needed. Table 5 PROGRAMMING Activity Steps Adjusting Temperature Step 1: Select the “POOL / SPA” button to choose the thermostat to adjust. Step 2: Select the “UP” or “DOWN” button to increase or decrease the desired
“Desired Temp” Setting Desired Water Temperature “Water Temp” Actual Water Temperature “Heating” Actively Heating Water Table 3 BUTTONS BUTTONS EXPLANATION SUPPLEMENTAL INFORMATION “Pool / Spa” Select between Pool and Spa Please note – this does not turn off equipment. It only allows a user to toggle between the Pool thermostat and the Spa thermostat. “Up” Select to raise temperature set point or move up in a menu choice “Down” Select to lower temperature set point or move down in a menu choice
EQUIPMENT CLEARANCES Keep the area immediately adjacent to the heat pump clear of items such as shrubs and bushes, lawn furniture, chemicals containers, etc. These items can prevent air from circulating properly through the heater, and will result in inefficient operation and/or damage to the heat pump. Figure 1 Figure 2 Overhang with Gutter 5 feet Minimum Clearance Overhead Rain Run-Off Must Be Directed Away From Heater (Front) 30” Minimum Clearance (Rear) 12” Clearance for all IceBreaker / Hea
Applying Power to The Controller:...............................................................................................8 2. Turning The Heat Pump ON:.........................................................................................................8 3. Turning The Heat Pump OFF:.......................................................................................................8 4. Selecting Pool / Spa Thermostat Settings:.........................................................
In areas where the winter temperatures are low, a 30 minute setting is recommended. The heat pump is equipped with an electronic defrost control. This solid state defrost control . operatesinconjunctionwithanextemal sensorlocatedata"cold"spotontheoutdoor coil. The control operates on a "Time/Temp" toinitiateand"Temp"toterminatethecycle. The control will initiate a defrost cycle every60minutes(setbythefactory)ifthecoiltemperature atthesensor is approximately 35"F or less. As the coil is being def
AquaCal AutoPilot Pool & Spa Heat Pump Owner’s Manual and Installation Guide MODEL / SERIAL NUMBER Attention Installer: This manual is purchaser’s property; leave with heat pump owner! PN: LTP0048 REV 2 NOTES TABLE OF CONTENTS WELCOME TO THE TEAM ----------------------------------------------5 HEAT PUMP OPTIONS -------------------------------------------------6 HOW A HEAT PUMP WORKS ------------------------------------------7 SAFETY INFORMATION------------------------------------------------8 QU