Patent Numbers 6,295,980 5,318,007 - 5,228,618 5,201,307 - 4,595,825 _WARNING_ FOR YOUR SAFETY - READ BEFORE OPERATING • If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. • Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or death. Installation and service must be performed by a qualified installer, service agency or the gas supplier. • Do

Pentair MASTERTEMP 200K BTU/HR

Descargado: 2Tamaño del archivo: 7 mb    Fabricar: Pentair  
Categoría: Piscinas

This manual supplies information for the installation, operation, and servicing of the appliance. READ AND REVIEW THIS MANUAL COMPLETELY before proceeding with an installation. Its use will reduce service calls and chance of injury and will lengthen product life. If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Call (800) 831-7133 for additional free copies of these instructions. FOR YOUR SAFETY Do

Pentair MASTERTEMP 300K BTU/HR

Descargado: 0Tamaño del archivo: 7 mb    Fabricar: Pentair  
Categoría: Piscinas

3. Test the operation of the pressure relief valve by lifting the valve lever. 4. Test for proper operation of the pressure switch. (See “SWITCH SETTINGS” for testing instructions). 5. On enclosed installations with high-temperature Special Gas Vent systems, repeat the “Final Installation Check,” page 15. Check for evidence of joint leakage. Make sure that joints have not slipped partially or completely apart. Check pipe and fittings for cracks or breaks. The combustion air blower is permanently

Pentair MASTERTEMP 400K BTU/HR

Descargado: 12Tamaño del archivo: 7 mb    Fabricar: Pentair  
Categoría: Piscinas

To override the time delay, push the Max. Temp. Set Point button again. D. Press the ^ ^^ TEMP or Ў ЎЎ TEMP button on the control panel and set maximum spa temperature to 104°F (40°C) or less. E. Wait up to 30 seconds; the SPA ON light will go off and the unit will shut down. To override the time delay, push the Max. Temp. Set Point button again. 4. Reinstall the access door panels. Initial Troubleshooting Only qualified, trained service technicians with appropriate test equipment should service

Pentair MASTERTEMP 250K BTU/HR

Descargado: 0Tamaño del archivo: 7 mb    Fabricar: Pentair  
Categoría: Piscinas

Use a Listed roof flashing, roof jack, or roof thimble for all roof penetrations. Do not fill the space around the vent (that is, the clear air space in the thimble or firestop) with insulation. The roof opening must be located so that the vent is vertical. 6. Vent Termination – Vertical (See Figures 12A and 12B, page 13, for height of vent termination above the roof. See Table 7, Page 15, for Listed terminations.) Use a Listed vent terminal specified by local and national codes and your manufac

Pentair IntelliComm

Descargado: 11Tamaño del archivo: 7 mb    Fabricar: Pentair  
Categoría: Piscinas

to 5 P.M.) Phone: (800) 831-7133 Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) 831-7133 (Ext. 6312) Fax: (800) 284-4151 Web sites: visit and © 2005 Pentair Water Pool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 Trademarks and disclaimers: IntelliFlo, IntelliTouch and the Pentair Water Pool and Spa logo are trademarks of Pentair Wate

Pentair Variable Speed Pump IntelliFlo

Descargado: 10Tamaño del archivo: 7 mb    Fabricar: Pentair  
Categoría: Piscinas

You can schedule start and stop times for each feature. All Features are operated using Flow control. The Feature mode and Filter mode are run simultaneously. The three types of features are; Features 1 & 2, Features 3 -9 and M.O. Flo: Features 1 and 2 Feature 1 and Feature 2 run for a pre-defined duration with a specifically set flow. If Feature 1 or Feature 2 buttons are pressed, all other Features are temporarily deactivated. Feature 1 or Feature 2 cannot be used in Backwash Mode. Features 1

Pentair Pump Waterfall

Descargado: 0Tamaño del archivo: 7 mb    Fabricar: Pentair  
Categoría: Piscinas

Ajústela para alta velocidad. Encuentre y arregle la fuga. Abra la restricción de la tubería de retorno. Limpie el canasto. Limpie la obstrucción. Encuentre y arregle la fuga. Encuentre y abra la restricción. Revise el interruptor de corriente y vuélvalo a ajustar. Revise el interruptor de circuito y vuélvalo a ajustar, si se vuelve a disparar póngase en contacto con un electricista. Revise el modo del contador de tiempo. Haga que un electricista revise la conexiones del terminal. Camb

Pentair Hot Tub

Descargado: 0Tamaño del archivo: 6 mb    Fabricar: Pentair  
Categoría: Otros accesorios para la casa

Mantenga un minimo de espacio como se le indica. Instale a 4 pies (120 cm) por debajo y 4 pies (120 cm) horizontales de cualquier otra entrada. No instale el calentador a menos de 6 “ (15 cm) de cualquier valla o cerca, pared o maleza, o cualquier material combustible, ni a menos de 18 “ (45 cm) del area de las tuberias. Mantenga por lo menos 24 “ (60 cm) de distancia de la parte frontal del calentador. Instalacion (contd.) KIT DE VENTILACION EXTERNA TIPO CHIMENEA .IMPORTANTE! Para colocar el ca

Pentair MiniMax 200

Descargado: 0Tamaño del archivo: 6 mb    Fabricar: Pentair  
Categoría: Piscinas

NPT PRV. NOTE: (A.S.M.E. version varies slightly. It is of bronze construction, and is supplied with the A.S.M.E. Section IV, pressure relief valve pre-installed at factory.) Test the relief valve at least once a year by lifting up lever. Figure 29. ENERGY SAVING TIPS 1. If possible, keep pool or spa covered when not in use. This will not only cut heating costs, but also keep dirt and debris from settling in the pool and conserve chemicals. 2. Reduce the pool thermostat setting to 78° F.